HP storageworks director 2/140 Service Manual page 348

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

Event Code Tables
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
Five cooling fans (out of six) failed or are rotating at insufficient angular velocity.
The remaining fan is operational. The amber LED illuminates at the rear of both fan
modules.
Action:
Replace both fan modules
Event Data:
The first byte of event data (byte 0) specifies the failed fan numbers.
Distribution:
Director
EWS
Event
Log
Message:
Cooling fan propeller failed.
Severity:
Major.
Explanation:
All six cooling fans failed or are rotating at insufficient angular velocity. The amber
LED illuminates at the rear of both fan modules.
Action:
Replace both fan modules
Event Data:
The first byte of event data (byte 0) specifies the failed fan numbers.
Distribution:
Director
EWS
Event
Log
348
Event Code: 304
HAFM appliance
System
Event
Error
Log
LED
Event Code: 305
HAFM appliance
System
Event
Error
Log
LED