Message:
Embedded port anomaly detected.
Severity:
Informational.
Explanation:
The CTP card detected a deviation in the normal operating mode or status of the
embedded port.
Action:
No action required. An additional event code is generated if this incident exceeds
an error threshold or results in a port failure.
Event Data:
Byte 0 = port number.
Byte 1 = engineering reason code.port.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 and 9 = high-availability error callout #1.
Bytes 10 and 11 = high-availability error callout #2.
Byte 12 = detecting port.
Byte 13 = connected port.
Byte 14 = participating SBAR assembly.
Bytes 16 and 17 = high-availability error callout #3.
Bytes 18 and 19 = high-availability error callout #4.
Distribution:
Director
EWS
Event
Log
Message:
Serial number mismatch detected.
Severity:
Informational
Explanation:
This event occurs when the sequence number or OEM serial number in the system
VPD (read from the backplane) does not match the sequence number and serial
number that were saved in NVRAM the last time the switch was IPLed. This event
will occur normally when a CTP is moved from one switch to the master position of
another switch. This event may occur abnormally when a hardware problem is
causing a problem reading the system VPD from the backplane.
Action:
None. Any configured feature keys will be cleared, configuration information will
be synched with the backplane VPD, and the CTP will automatically be IPLed.
Director 2/140 Service Manual
Event Code: 442
HAFM appliance
System
Event
Error
Log
LED
Event Code: 450
E-Mail
Call
Home
Event Code Tables
Host
Sense
Link
Info
Incident
363