HP storageworks director 2/140 Service Manual page 374

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

Event Code Tables
Distribution:
Director
EWS
Event
Log
Message:
SFP optical transceiver hot-removal completed.
Severity:
Informational.
Explanation:
An SFP optical transceiver was removed while the director was powered on and
operational.
Action:
No action required.
Event Data:
Byte 0 = port number (0-127 and 132-143).
Bytes 4 through 7 = elapsed millisecond tick count.
Distribution:
Director
EWS
Event
Log
Message:
SFP optical transceiver failure.
Severity:
Major.
Explanation:
An SFP optical transceiver in a UPM card failed. The amber LED corresponding to
the port illuminates to indicate the failure. Other ports remain operational if their
LEDs are extinguished.
Action:
Replace the failed transceiver with a functional transceiver of the same type.
Event Data:
Byte 0 = port number (0-127 and 132-143).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.