HP storageworks director 2/140 Service Manual page 361

Hide thumbs Also See for storageworks director 2/140:
Table of Contents

Advertisement

Action:
Verify the Ethernet cable, hub, and other devices are properly connected and
operational.
Event Data:
Bytes 0 through 3 = sum of all receive errors (total_recv_error).
Bytes 4 through 7 = frame count where received frame had from 1 to 7 bits after
last received full byte (dribble_bits_cnt). CRC error counter updated but frame not
processed.
Bytes 8 through 11 = frame count where received frame had bad CRC
(CRC_error_cnt). Frame not processed.
Bytes 12 through 15 = frame count received with less than 64 bytes (runt_cnt).
Broadcast frames count but do not contribute to threshold. Frame not processed.
Bytes 16 through 19 = frame count received with more than 1518 bytes
(extra_data_cnt). Broadcast frames count but do not contribute to threshold. Frame
not processed.
Distribution:
Director
EWS
Event
Log
Message:
Ethernet adapter reset.
Severity:
Minor.
Explanation:
The active CTP card Ethernet adapter was reset in response to an internally detected
error. A card failure is not indicated. The director-to-HAFM appliance connection
terminates, but automatically recovers after the reset.
Action:
Perform the data collection procedure and return the backup CD to HP support
personnel.
Event Data:
Bytes 0 through 3 = reason for adapter reset, least significant byte first
(reset_error_type) 1 = completion notification for timed-out frame transmission.
Distribution:
Director
EWS
Event
Log
Director 2/140 Service Manual
HAFM appliance
System
Event
Error
Log
LED
Event Code: 432
HAFM appliance
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
Event Code Tables
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident
361

Advertisement

Table of Contents
loading

Table of Contents