Distribution:
Director
EWS
Event
Log
Message:
UPM card failure.
Severity:
Major.
Explanation:
The indicated UPM card failed.
Action:
Replace the indicated UPM card with a functional UPM card of the same type.
Perform the data collection procedure and return the backup CD and faulty card to
HP support personnel.
Event Data:
Byte 0 = UPM slot position (00 through 0F).
Byte 1 = engineering reason code.
Bytes 4 through 7 = elapsed millisecond tick count.
Bytes 8 through 11 = reason code specific data.
Distribution:
Director
EWS
Event
Log
Message:
UPM card revision not supported.
Severity:
Minor.
Explanation:
The indicated UPM card is not recognized and the four ports display as uninstalled
to the director firmware.
Action:
Ensure the director model supports the operating firmware version. If the firmware
version is supported, replace the UPM card with a functional card. Perform the data
collection procedure and return the backup CD and faulty card to HP support
personnel.