CTP Card Events (400 through 499)

Message:
Power-up diagnostics failure.
Severity:
Major.
Explanation:
Power-on self tests (POSTs) detected a faulty field-replaceable unit (FRU) as
indicated by the event data.
Action:
Replace the failed FRU with a functional FRU. Perform the data collection procedure
and return the backup CD and faulty FRU to HP support personnel.
Event Data:
Byte 0 = FRU code as follows: 01 = backplane, 02 = CTP card, 03 = SBAR
assembly, 05 = fan module,
06 = power supply, and 08 through 0F = UPM cards.
Byte 1 = FRU slot number.
Distribution:
Director
EWS
Event
Log
Message:
CTP card reset.
Severity:
Informational.
Explanation:
The indicated CTP card reset after a director power-on, CTP card installation,
hardware IML (CTP card faceplate), or software IPL. An IPL can be user-initiated at
the Element Manager, or occur automatically after a firmware fault (event code
411). The event data indicates the type of reset.
Action:
No action required.
Event Data:
Byte 0 = reset type as follows: 00 = power-on hot-insert, 02 = IML, 04 = IPL,
08 = reset by other CTP card, 40 = partition switch, or 80 = dual CTP card
hot-insert.