3. Disconnect both ends of the fiber optic jumper cable.
4. Clean the fiber optic connectors
5. Reconnect the fiber optic jumper cable.
6. Unblock the port
7. Monitor port operation for approximately five minutes.
Did the link incident recur?
YES
↓
37
Disconnect the fiber optic jumper cable from the director port and connect the
cable to a spare port.
Is a link incident reported at the new port?
YES
↓
38
The attached device is causing the recurrent link incident. Notify the customer of
the problem and have the system administrator:
1. Inspect and verify operation of the attached device.
2. Repair the attached device if a failure is indicated.
3. Monitor port operation for approximately five minutes.
Director 2/140 Service Manual
page 194).
("Unblock a
NO
The Fibre Channel link and director are operational. Exit MAP.
NO
Go to
step
39.
("Clean Fiber Optic
Port" on page 203).
Diagnostics
Components" on
133