Diagnostics
33
The switch and attached device are performing a Fibre Channel link reset. This is
a transient state. Wait approximately 30 seconds and inspect port state and LED
behavior.
Did the link recover and resume operation?
NO
Go to
34
A link incident message appeared in the Link Incident Log or in the Link
Incident field of the Port Properties dialog box; or an event code 581, 582, 583,
584, 585, or 586 was observed at the console of an OSI server attached to the
switch reporting the problem.
Clear the link incident for the port.
1. At the Hardware View, right-click the port. A pop-up menu appears.
2. Click Clear Link Incident Alert(s). The Clear Link Incident Alert(s) dialog
Figure 29: Clear Link Incident Alert(s) dialog box
3. Click the This port (n) only radio button (where n is the port number) and
4. Monitor port operation for approximately five minutes.
Did the link incident recur?
YES
108
YES
The Fibre Channel link and switch appear operational. Exit MAP.
step
1.
box displays
(Figure
click OK. The link incident clears.
NO
The problem is transient and the Fibre Channel link and switch
appear operational. Exit MAP.