Troubleshooting The Ptx5000 Pics And Pic Transceivers; Troubleshooting Ptx5000 Pics - Juniper PTX5000 Hardware Manual

Packet transport router
Hide thumbs Also See for PTX5000:
Table of Contents

Advertisement

Troubleshooting the PTX5000 PICs and PIC Transceivers

IN THIS SECTION

Troubleshooting PTX5000 PICs | 625

Troubleshooting PTX5000 PIC Transceivers | 628
Troubleshooting PTX5000 PICs
IN THIS SECTION
Problem | 625
Solution | 625
Problem
Description
A PIC LED lit red indicates a problem with the PIC.
Solution
To troubleshoot a PIC:
1. Check the STATUS LED of the PIC. Look at the LEDs located on the PIC faceplate. For information
about the meaning of LED states on different PICs, see the
2. Issue the show chassis alarms command to check for alarms. For information about the alarms on
different PICs, see the
PTX Series Interface Module Reference
user@host> show chassis alarms
1 alarm currently active
Alarm time
2012-11-02 17:46:53 PDT Major FPC 3 PIC 1 Failure
Class Description
PTX Series Interface Module
625
Reference.