PTX5000 Alarm Messages Overview
IN THIS SECTION
Chassis Alarm Messages | 570
Interface Alarm Messages | 571
When the Routing Engine detects an alarm condition, it lights the red or yellow alarm LED on the craft
interface as appropriate, trips the corresponding alarm relay contact, and reports the cause of the alarm
in the craft interface LCD.
Chassis Alarm Messages
Chassis alarm messages Indicate a problem with a chassis component such as the cooling system or
power system.To view a more detailed description of the alarm cause, issue the show chassis alarms CLI
command:
user@host> show chassis alarms
17 alarms currently active
Alarm time
2011-12-07 11:28:52 PST Minor SIB 8 FPC Link Error
2011-12-07 11:28:52 PST Minor SIB 7 FPC Link Error
2011-12-07 11:28:52 PST Minor SIB 6 FPC Link Error
2011-12-07 11:28:52 PST Minor SIB 5 FPC Link Error
2011-12-07 11:28:52 PST Minor SIB 4 FPC Link Error
2011-12-07 11:28:52 PST Minor SIB 3 FPC Link Error
2011-12-07 11:28:52 PST Minor SIB 2 FPC Link Error
2011-12-07 11:28:52 PST Minor SIB 1 FPC Link Error
2011-12-07 11:28:52 PST Minor SIB 0 FPC Link Error
2011-12-07 11:15:42 PST Minor No Redundant Power for FPC 0-7
2011-12-07 11:15:42 PST Minor No Redundant Power for Rear Chassis
2011-12-07 11:15:42 PST Minor No Redundant Power for Fan 0-2
2011-12-07 11:15:42 PST Minor PDU 1 PSM 3 Absent
2011-12-07 11:15:42 PST Minor PDU 1 PSM 2 Absent
2011-12-07 11:15:42 PST Minor PDU 1 PSM 1 Absent
2011-12-07 11:15:42 PST Minor PDU 1 PSM 0 Absent
2011-12-07 11:15:42 PST Minor PDU 1 Absent
Class Description