Maintaining T320 Pics And Pic Cables - Juniper Core Router T Series Hardware Manual

Hide thumbs Also See for Core Router T Series:
Table of Contents

Advertisement

Maintaining T320 PICs and PIC Cables

Purpose
Action
Copyright © 2018, Juniper Networks, Inc.
For optimum router performance, verify the condition of the PICs and PIC cables.
On a regular basis:
Check the LEDs on PIC faceplates. A PIC LED lit green indicates the PIC is functioning
normally. The meaning of the LED states differs for various PICs. For more information,
see the interface module reference for your device. If the FPC that houses the PIC
detects a PIC failure, the FPC generates an alarm message to be sent to the Routing
Engine.
Issue the CLI
show chassis fpc pic-status
numbered from
0
through
user@host> show chassis fpc pic-status
Slot 0
Online
PIC 0
Online
PIC 2
Present
PIC 3
Online
Slot 2
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
Slot 3
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
PIC 3
Online
Slot 4
Online
PIC 0
Online
Slot 6
Online
PIC 0
Online
PIC 1
Online
Slot 7
Online
PIC 0
Online
For further description of the output from the command, see show chassis fpc.
Use the cable management system to support cables and prevent cables from
dislodging or developing stress points.
Place excess cable out of the way in the cable management system. Do not allow
fastened loops of cable to dangle from the connector or cable management system,
because this stresses the cable at the fastening point. Putting fasteners on the loops
helps to maintain their shape.
Keep the cable connections clean and free of dust and other particles, which can cause
drops in the received power level. Always inspect cables and clean them if necessary
before connecting an interface.
Label both ends of PIC cables to identify them.
The following guidelines apply specifically to fiber-optic cable:
command. The PIC slots in an FPC are
3
, top to bottom:
E-FPC Type 3
1x 10GE(LAN),DWDM
1x OC-192 SONET XFP- Hardware Error
1x 10GE(LAN),XENPAK
E2-FPC Type 2
1x OC-48 SONET, SMIR
2x OC-12 ATM-II IQ, MM
8x 1GE(LAN), IQ2
FPC Type 3
1x 10GE(LAN),XENPAK
1x 10GE(LAN),XENPAK
8x 1GE(TYPE3), IQ2
8x 1GE(TYPE3), IQ2
FPC Type 4
4x OC-192 SONET XFP
FPC Type 3
4x OC-48 SONET
1x Tunnel
FPC Type 4
1x OC-768 SONET SR
Chapter 31: Maintaining Components
283

Advertisement

Table of Contents
loading

This manual is also suitable for:

Core router t320

Table of Contents