Removing a Cable for an External Clocking Device From a PTX5000 CCG

To remove a cable with RJ-48 connectors from a BITS A or BITS B port on the CCG:
1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
one of the ESD points on the chassis.
2. Disconnect the cable from the T1 external clocking device.
3. Disconnect the cable from the BITS A or BITS B port on the CCG.

Installing a Cable Between an External Clocking Device and a PTX5000 CCG

To connect a cable with RJ-48 connectors to an BITS A or BITS B port on the CCG:
1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
one of the ESD points on the chassis.
2. Plug one end of the cable into the appropriate BITS A or BITS B port on the CCG.
3. Plug the other end of the cable into the T1 external clocking device.
4. Verify that the LINK LED for the port is lit steadily green, and that the FAULT LED is not lit.
5. Issue the show chassis synchronization command to check the status of the port.
user@host> show chassis synchronization
user@host> show chassis synchronization
Clock Synchronization Status :
Clock module on CCG 0
Current state
Current clock state
Selected for
Selected since
Deviation (in ppm)
Last deviation (in ppm): +0.51
RELATED DOCUMENTATION
PTX5000 Craft Interface Description | 19
PTX5000 Craft Interface LEDs | 23
PTX5000 Centralized Clock Generator Description | 29
PTX5000 Centralized Clock Generator LEDs | 30
Troubleshooting the PTX5000 Centralized Clock Generators | 571
Prevention of Electrostatic Discharge Damage
: Online - Master
: internal
: 1 hour, 27 minutes, 26 seconds
: 2011-12-09 11:21:07 PST
: +0.51