Troubleshooting The Ptx5000 Power System - Juniper PTX5000 Hardware Manual

Packet transport router
Hide thumbs Also See for PTX5000:
Table of Contents

Advertisement

Table 87: Troubleshooting Temperature Alarms
Alarm
LCD
CLI Message
Type
Message
sib-number
sib-number Temperature
Warm
Warm
FPC-
FPC
FPC
number PIC
PIC-number Temperature
PIC-number
Warm
Warm

Troubleshooting the PTX5000 Power System

IN THIS SECTION
Troubleshooting the PTX5000 Power Distribution Units | 592
Troubleshooting the PTX5000 Power Supply Modules | 601
(Continued)
Alarm Condition
The SIB temperature
exceeded the warm
temperature
threshold.
FPC-number PIC
The FPC
temperature
exceeded the warm
temperature
threshold.
Solution
Verify that the fans in the vertical
fan tray have not failed.
Verify that fans in the vertical fan
tray are running at appropriate
speed.
show chassis sib
Issue the
command.
Verify that there is sufficient air
flow to the rear fan tray.
Verify that the fans in the
horizontal fan trays have not
failed.
Verify that fans in the horizontal
fan trays are running at the
appropriate speed.
show chassis fpc
Issue the
command.
591