Table 87: Troubleshooting Temperature Alarms
Alarm
LCD
CLI Message
Type
Message
sib-number
sib-number Temperature
Warm
Warm
FPC-
FPC
FPC
number PIC
PIC-number Temperature
PIC-number
Warm
Warm
Troubleshooting the PTX5000 Power System
IN THIS SECTION
Troubleshooting the PTX5000 Power Distribution Units | 592
Troubleshooting the PTX5000 Power Supply Modules | 601
(Continued)
Alarm Condition
The SIB temperature
exceeded the warm
temperature
threshold.
FPC-number PIC
The FPC
temperature
exceeded the warm
temperature
threshold.
Solution
•
Verify that the fans in the vertical
fan tray have not failed.
•
Verify that fans in the vertical fan
tray are running at appropriate
speed.
•
show chassis sib
Issue the
command.
•
Verify that there is sufficient air
flow to the rear fan tray.
•
Verify that the fans in the
horizontal fan trays have not
failed.
•
Verify that fans in the horizontal
fan trays are running at the
appropriate speed.
•
show chassis fpc
Issue the
command.
591