4. Verify that the DC IN OK LED on the PSM faceplate is lit steadily.
Figure 195: Installing a PSM

Replacing a PTX5000 High Capacity Delta AC PDU

IN THIS SECTION

Removing a PTX5000 High Capacity Delta AC PDU | 386

Installing a PTX5000 High Capacity Delta AC PDU | 390
Removing a PTX5000 High Capacity Delta AC PDU
The PTX5000 has two redundant, load-sharing PDUs. Each PDU is hot-insertable and hot-removable.
The High Capacity Delta AC PDU weighs 63.3 lb (28.7 kg).
To remove a High Capacity Delta AC PDU:
1.
Switch off the customer-site circuit breakers to the PDU that is being removed.