Replacing a PTX5000 High Capacity DC PSM
IN THIS SECTION
Removing a PTX5000 High Capacity DC PSM | 447
Installing a PTX5000 High Capacity DC PSM | 448
Removing a PTX5000 High Capacity DC PSM
To remove a High Capacity DC PSM:
1. Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect the strap to
one of the ESD points on the chassis.
2. Loosen the captive screws on the door covering the PSMs and open the door.
3. Press down the locking tab and then pull out the PSM by using the ejector handle.
CAUTION: Each High Capacity DC PSM weighs approximately 10.1 lb (4.6 kg). Be
prepared to support the full weight of the PSM as you remove it from the PTX5000.
4. Place one hand underneath the PSM to support it and slide it completely out of the chassis.
Figure 242: Removing a High Capacity DC PSM
447