Maintaining The M10I Pics And Pic Cables - Juniper M10i Hardware Manual

Multiservice edge router
Hide thumbs Also See for M10i:
Table of Contents

Advertisement

Related
Documentation

Maintaining the M10i PICs and PIC Cables

Purpose
Action
Copyright © 2010, Juniper Networks, Inc.
All manuals and user guides at all-guides.com
user@host> show chassis environment
Class Item
...
Fans
Left Fan 1
Left Fan 2
Left Fan 3
Left Fan 4
Left Fan 5
Left Fan 6
Left Fan 7
Left Fan 8
...
For further description of the output from the command, see the Junos OS System Basics
and Services Command Reference.
Installing an M10i Fan Tray on page 102
Troubleshooting the M10i Fan Tray on page 91
Replacing an M10i Fan Tray on page 101
For optimum performance, verify the condition of the PICs and PIC cables.
Check the LEDs on PIC faceplates. The meaning of the LED states differs for various
PICs. For more information, see the M10i Multiservice Edge Router PIC Guide. If the FPC
that houses the PIC detects a PIC failure, the FPC generates an alarm message to be
sent to the Routing Engine.
Issue the CLI
show chassis fpc pic-status
numbered from
0
through
user@host> show chassis fpc pic-status
Slot 0 Online
PIC 0
4x OC-3 SONET, MM
PIC 1
1x CSTM1, SMIR
PIC 3
2x OC-3 ATM, MM
Slot 1 Online
PIC 0
1x OC-12 SONET, MM
PIC 1
1x OC-12 ATM, MM
PIC 2
2x OC-3 ATM, MM
PIC 3
2x OC-3 ATM, MM
For further description of the output from the command, see the Junos OS System
Basics and Services Command Reference.
Use the cable management system (shown in Figure 1 on page 6) to support cables
and prevent cables from dislodging or developing stress points. Place excess cable
out of the way in the cable management system. Do not allow fastened loops of cable
to dangle from the connector or cable management system, because this stresses the
cable at the fastening point. Putting fasteners on the loops helps to maintain their
shape.
Chapter 13: Maintaining M10i Router Hardware Components
Status
Measurement
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
OK
Spinning at normal speed
command. The PIC slots in an FPC are
3
, top to bottom:
81