Input 2
Input 3
9. If you cannot determine the cause of the problem or need additional assistance, contact customer
support.
Table 88: Troubleshooting Power Distribution Unit Alarms
Alarm
LCD Display
Type
Message
pdu-number
Red
PDU
Not OK
pdu-number
PDU
Not Recognized
pdu-number
PDU
Absent
Mix of PDUs
PDU %d Conv
Failed
207
303
208
292
CLI Message
Alarm Condition
pdu-number
PDU
An electronic fuse has
tripped.
Not OK
pdu-number
PDU
The PDU is not
supported.
Not Recognized
pdu-number
PDU
The PDU is not
installed.
Absent
Mix of PDUs
Different types of PDUs
are present in the
chassis.
NOTE: Both AC and DC
PDUs might be present.
Zoning and nonzoning
PDUs might be present.
PDU %d Converter
One or more 36-V
booster converter fails
Failed
in a high-capacity PDU.
Solution
1. Remove and reinstall the
component that caused the
electronic fuse to trip.
2. Remove and reinstall the PDU
to reset the electronic fuses.
Install a supported PDU.
Two PDU are required at all
times. Install the PDU in the
empty slot.
Install the same type of PDUs in
each slot.
If two or more 36-V booster
converter fails, fan trays fail and
the router might get overheated.
Therefore, when this alarm is
raised, check the PDU and
replace the PDU if required.