8.
Slide the input power trays into the new PDU
Figure 225: Installing a 60-A Input Power Tray
9.
Tighten the captive screws on the input power tray. Use a Phillips (+) screwdriver.
10. Reinstall the PSMs at the front of the chassis.
11. Switch on the customer-site circuit breakers.
12. Verify that the DC IN LEDs on the PDU faceplate are lit steadily, indicating that the inputs are
receiving power.
13. Move the input power switch on the PDU to the on (|) position.
14. Verify that the SW ON LEDs are lit steadily, indicating that the input power switch for each input
power tray is on.
15. Verify that the PDU OK LED on the PDU faceplate is lit steadily, indicating that the PDU is
correctly installed and is functioning properly.
Replacing a PTX5000 60-A DC PDU Power Cable
IN THIS SECTION
Removing a PTX5000 60-A DC PDU Power Cable | 426
Installing a PTX5000 60-A DC PDU Power Cable | 427
(Figure 225 on page
425).
425