Table 98: Troubleshooting FPC Alarms
Alarm
LCD Message
Type
FPC
fpc-number
SIB Link Error
Table 99: Troubleshooting FPC LEDs
Label
Color
State
OK
-
Off
FAULT
Red
On steadily
SEE ALSO
PTX5000 FPC LEDs | 148
(Continued)
CLI Message
Alarm Condition
FPC
fpc-number
An FPC detected link errors
on the high speeds links
detects link
between an FPC and SIB.
error
This alarm might be caused
by an error either on an FPC
or on a SIB. The Packet
Forwarding Engine's
forwarding capacity might be
affected.
Description
FPC is offline or not seated properly.
FPC has failed.
Recovery
1. Restart the SIB, and then
the FPC. This might affect
the traffic.
2. If the problem persists,
replace the FPC.
3. If the problem still persists,
replace the particular SIB
that was associated with
the link error.
4. If you are unable to isolate
the problem, contact JTAC.
JTAC needs to analyze the
logs to determine further
action.
Recovery
Reinstall the FPC and verify the FPC.
Replace the FPC.