Table 4: SIB LEDs on the PTX5000 Craft Interface
Label
Color
State
–
Off
ACT
Green
On steadily
–
Off
Craft Interface Host Subsystem LEDs
Each host subsystem has three LEDs—labeled MASTER, OK, and FAIL—located to the right of the SIB
LEDs on the craft interface, that indicate the status of the host subsystem. The LEDs listed under
HOST0 show the status of the Routing Engine in slot RE0 and the CB in slot CB0. The LEDs listed under
HOST1 show the status of the Routing Engine in slot RE1 and the CB in slot CB1.
describes the functions of the host subsystem LEDs.
Table 5: PTX5000 Host Subsystem LEDs
Label
Color
MASTER
Green
–
OK
Green
–
FAIL
Red
–
Description
SIB is offline or absent.
SIB is in active mode and actively passing traffic.
SIB is either offline or not actively passing traffic.
State
Description
On steadily
Host subsystem is functioning as the primary.
Off
Host subsystem is offline or functioning as the backup.
On steadily
Host subsystem is online and is functioning normally.
Off
Host subsystem is offline or absent.
On steadily
Host subsystem has failed.
Off
No failure has been detected.
(Continued)
Table 5 on page 25
25