Juniper PTX5000 Hardware Manual page 611

Packet transport router
Hide thumbs Also See for PTX5000:
Table of Contents

Advertisement

2012-11-02 15:13:58 PDT Minor No Redundant Power for FPC 0-7
2012-11-02 15:13:57 PDT Minor No Redundant Power for Rear Chassis
2012-11-02 15:13:56 PDT Major PDU 0 PSM 2 Not OK
2012-11-02 15:13:56 PDT Minor No Redundant Power for Fan 0-2
2012-11-02 15:13:51 PDT Minor PDU 1 PSM 3 Absent
2012-11-02 15:13:51 PDT Minor PDU 1 PSM 2 Absent
2012-11-02 15:13:51 PDT Minor PDU 1 PSM 1 Absent
2012-11-02 15:13:51 PDT Minor PDU 1 PSM 0 Absent
2012-11-02 15:13:50 PDT Minor PDU 1 Absent
4. Check the display on the craft interface to determine the source of a yellow or red alarm). Junos OS
constantly updates the screen with status information for each component.
NOTE: From the rear of the chassis, the PDUs are labeled PDU1 and PDU0, from left to right.
5. Check the LEDs on each PDU faceplate. See
6. Verify that the DC power cable or the AC power cord from the power source to the PDU is not
damaged. If the insulation is cracked or broken, immediately replace the DC power cable or AC
power cord.
7. Check the status of the PDUs by issuing the show chassis environment pdu command. The state of the
PDU must be online. If the output indicates that a PSM in the PDU is present, see
the PTX5000 Power Supply Modules" on page
user@host> show chassis environment pdu
The following example shows output for a DC PDU.
user@host> show chassis environment pdu 0
PDU 0 status:
State
Hours Used
Firmware Version (MCU1)
Firmware Version (MCU2)
Firmware Version (MCU3)
Firmware Version (MCU4)
PDU 0 PSM 0 status:
State
Temperature
Table
8.
601.
Online
2161
02.03
02.01
02.01
02.01
Online
OK
35 degrees C / 95 degrees F
"Troubleshooting
593