Table 85: Troubleshooting Fan Tray Alarms
Alarm Type
LCD Message
Red
Fan Failure
Fans Missing
Yellow
Fan Removed
Table 86: Troubleshooting Fan Tray LEDs on the Craft Interface
Color
State
Description
Red
On steadily
The fan tray has failed.
Off
The fan tray is offline or absent.

Troubleshooting Temperature Alarms

IN THIS SECTION
Problem | 579
Solution | 579
OK
OK
OK
Spinning at 31% fan tray speed
OK
Spinning at 32% fan tray speed
CLI Message
Alarm Condition
fan-name Failure
A fan has failed.
Too many fans missing
A fan tray is missing or too
many fan trays have failed.
or failing
fan-name Removed
A fan tray has been
removed.
Recovery
Replace the fan tray.
Reinstall the fan tray in
the chassis.
Reinstall the fan tray in
the chassis.
Recovery
Replace the fan tray.
Reinstall the fan tray in the chassis.