Juniper PTX5000 Hardware Manual page 631

Packet transport router
Hide thumbs Also See for PTX5000:
Table of Contents

Advertisement

Problem
Description
The switch fabric in the PTX5000 includes the SIBs and the FPCs. A link that is in a down or error state
indicates a problem with the switch fabric.
Solution
To troubleshoot the switch fabric:
1. Verify that all nine SIBs and all installed FPCs are online. Use the show chassis fabric summary command
to check for errors.
user@host> show chassis fabric summary
FRU
State
SIB0
Online
SIB1
Online
SIB2
Online
SIB3
Online
SIB4
Online
SIB5
Online
SIB6
Online
SIB7
Online
SIB8
Online
FPC0
Empty
FPC1
Empty
FPC2
Online
FPC3
Empty
FPC4
Empty
FPC5
Online
FPC6
Empty
FPC7
Online
If a SIB or FPC is Offline, see
"Troubleshooting the PTX5000 Switch Interface Boards" on page 616
proceeding.
2. Use the show chassis fabric topology command to query the state of the links between the SIBs and
FPCs.