Juniper PTX3000 IPLC Features Manual

Juniper PTX3000 IPLC Features Manual

Packet transport router integrated photonic line system
Hide thumbs Also See for PTX3000 IPLC:
Table of Contents

Advertisement

Quick Links

®
Junos
OS
PTX3000 Integrated Photonic Line System
Feature Guide
Modified: 2018-07-03
Copyright © 2018, Juniper Networks, Inc.

Advertisement

Table of Contents
loading

Summary of Contents for Juniper PTX3000 IPLC

  • Page 1 ® Junos PTX3000 Integrated Photonic Line System Feature Guide Modified: 2018-07-03 Copyright © 2018, Juniper Networks, Inc.
  • Page 2 END USER LICENSE AGREEMENT The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use with) Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License Agreement (“EULA”) posted at https://www.juniper.net/support/eula/.
  • Page 3: Table Of Contents

    Understanding How to Configure Wavelengths on the IPLC Ports ..10 Understanding How to Configure the Wavelength Operational Mode ..10 Copyright © 2018, Juniper Networks, Inc.
  • Page 4 Monitors ............51 Copyright © 2018, Juniper Networks, Inc.
  • Page 5 ....460 show chassis fpc optical-properties amplifier-chain ila summary ... 461 Copyright © 2018, Juniper Networks, Inc.
  • Page 6 ..481 show chassis fpc optical-properties amplifier-chain ila pm-interval ..484 show chassis fpc optical-properties amplifier-chain ila pm-previousday ..488 Copyright © 2018, Juniper Networks, Inc.
  • Page 7 Figure 6: Example Topology and Configuration ......74 Copyright © 2018, Juniper Networks, Inc.
  • Page 8 PTX3000 Integrated Photonic Line System Feature Guide viii Copyright © 2018, Juniper Networks, Inc.
  • Page 9 Table 18: show chassis fpc optical-properties mfg info Output Fields ..124 Table 19: show chassis fpc optical-properties ocm Output Fields ... . 126 Copyright © 2018, Juniper Networks, Inc.
  • Page 10 Table 44: TCA Descriptions ......... . 489 Copyright © 2018, Juniper Networks, Inc.
  • Page 11: About The Documentation

    ® To obtain the most current version of all Juniper Networks technical documentation, see the product documentation page on the Juniper Networks website at https://www.juniper.net/documentation/ If the information in the latest release notes differs from the information in the documentation, follow the product Release Notes.
  • Page 12: Merging A Full Example

    /var/tmp directory on your routing platform. commit { file ex-script-snippet.xsl; } Move to the hierarchy level that is relevant for this snippet by issuing the following configuration mode command: [edit] Copyright © 2018, Juniper Networks, Inc.
  • Page 13: Documentation Conventions

    Table 2: Text and Syntax Conventions Convention Description Examples Bold text like this Represents text that you type. To enter configuration mode, type the configure command: user@host> configure Copyright © 2018, Juniper Networks, Inc. xiii...
  • Page 14 GUI Conventions Bold text like this Represents graphical user interface (GUI) In the Logical Interfaces box, select items you click or select. All Interfaces To cancel the configuration, click Cancel Copyright © 2018, Juniper Networks, Inc.
  • Page 15: Documentation Feedback

    We encourage you to provide feedback, comments, and suggestions so that we can improve the documentation. You can provide feedback by using either of the following methods: Online feedback rating system—On any page of the Juniper Networks TechLibrary site , simply click the stars to rate the https://www.juniper.net/documentation/index.html content, and use the pop-up form to provide us with information about your experience.
  • Page 16: Opening A Case With Jtac

    Download the latest versions of software and review release notes: https://www.juniper.net/customers/csc/software/ Search technical bulletins for relevant hardware and software notifications: https://kb.juniper.net/InfoCenter/ Join and participate in the Juniper Networks Community Forum: https://www.juniper.net/company/communities/ Open a case online in the CSC Case Management tool: https://www.juniper.net/cm/...
  • Page 17: Overview

    PART 1 Overview Understanding the PTX3000 Integrated Photonic Line System Architecture and Configuration on page 3 Understanding Optical Supervisory Channel Communication in the Amplifier Chain on page 11 Copyright © 2018, Juniper Networks, Inc.
  • Page 18 PTX3000 Integrated Photonic Line System Feature Guide Copyright © 2018, Juniper Networks, Inc.
  • Page 19: Understanding The Ptx3000 Integrated Photonic Line System Architecture And Configuration

    Junos OS CLI and optionally through the Connectivity Services Director (CSD) application running on the Junos Space Network Management Platform. To complete the optical solution, Juniper Networks integrated 100G Coherent transponders can be leveraged, along with the IPLC base module, IPLC expansion module, optical ILA and CSD to provide an end-to-end, fully managed packet optical solution.
  • Page 20: Overview

    Line IN Line OUT Juniper Networks’ optical inline amplifier (ILA) in the optical fiber network. Optical ILA nodes are typically placed into the network where the fiber length is greater than 80—100 km. For a complete description of the IPLC hardware and optical ILA, see the...
  • Page 21: Junos Space Connectivity Services Director

    Performance Monitors Alarms and analog performance monitors are available to allow expert or non-expert users easily identify and localize faults. Performance monitors monitor analog data and Copyright © 2018, Juniper Networks, Inc.
  • Page 22: Understanding The Integrated Photonic Line Card Architecture

    32 odd channels from the IPLC base module. In the demultiplexing-drop path, the 32 even channels are separated from the odd channels using a deinterleaver. All 64 channels go through the main common components used Copyright © 2018, Juniper Networks, Inc.
  • Page 23: Two-Degree Node

    Booster EDFA (E1) output Preamplifier EDFA (E2) output The combined channels of the local add function at the input of the WSS, which indicates which channels (both odd and even channels) are being added locally Copyright © 2018, Juniper Networks, Inc.
  • Page 24: Iplc Expansion Module Functional Components

    IPLC base module and the IPLC expansion module. Related Integrated Photonic Line Card Base and Expansion Module Overview on page 3 Documentation Understanding How to Configure the Integrated Photonic Line Card on page 9 Copyright © 2018, Juniper Networks, Inc.
  • Page 25: Understanding How To Configure The Integrated Photonic Line Card

    FPC or PIC slot. These slot requirements are especially important if you are configuring a two-degree node or increasing the channel capacity to 64 channels. BEST PRACTICE: We recommend that you place the IPLC modules into the same FPC/PIC slot pair on the PTX3000 chassis. Copyright © 2018, Juniper Networks, Inc.
  • Page 26: Understanding How To Configure Wavelengths On The Iplc Ports

    For more information, see “Configuring a Two-Degree Node for Express Traffic” on page Related Understanding the Integrated Photonic Line Card Architecture on page 6 Documentation Integrated Photonic Line Card Base and Expansion Module Overview on page 3 Copyright © 2018, Juniper Networks, Inc.
  • Page 27: Understanding Optical Supervisory Channel Communication In The Amplifier Chain

    (ILA) over the optical supervisory channel (OSC) of the PTX3000 integrated photonic line system. This topic provides an overview of the OSC communication across the PTX3000 integrated photonic line system when you are using Juniper Networks optical inline amplifiers (ILA)s in the amplifier chain. It also describes the control and manage capabilities of the optical ILA through the Junos OS CLI.
  • Page 28: Understanding How The Optical Ila Is Managed And Controlled

    ILA in the amplifier chain. You can manage the optical ILA using an SNMP network management system (NMS), Juniper Networks Connectivity Services Director over the DMI interface, the user interface of the optical ILA, or through the Junos OS CLI.
  • Page 29: Snmp Management Overview And Configuration

    ILA in the amplifier chain. SNMP traps are propagated from each optical ILA to the anchor IPLC and out to the SNMP NMS. Copyright © 2018, Juniper Networks, Inc.
  • Page 30: Os Cli

    OSC (OSC_A and OSC_B), see show chassis fpc optical-properties amplifier-chain ila osc VOA (VOA_A and VOA_B), see show chassis fpc optical-properties amplifier-chain ila voa Alarms, see show chassis fpc optical-properties amplifier-chain ila alarms Copyright © 2018, Juniper Networks, Inc.
  • Page 31: Understanding How To Configure The Osc Using The Junos Os Cli

    Configuring the Optical Supervisory Channel Across the Amplifier Chain of the PTX3000 Integrated Photonic Line System on page 33 Example: Configuring the Optical Supervisory Channel for the Integrated Photonic Line System and Optical Inline Amplifier on page 73 Copyright © 2018, Juniper Networks, Inc.
  • Page 32 PTX3000 Integrated Photonic Line System Feature Guide Copyright © 2018, Juniper Networks, Inc.
  • Page 33: Integrated Photonic Line Card And Optical Inline Amplifier Configuration

    Switching Wavelengths on the IPLC to Optical Interfaces in a Local or Remote Chassis on page 27 Configuring the Optical Supervisory Channel in the Amplifier Chain When Using the Optical Inline Amplifier on page 33 Configuring Performance Monitor Thresholds on page 45 Copyright © 2018, Juniper Networks, Inc.
  • Page 34 PTX3000 Integrated Photonic Line System Feature Guide Copyright © 2018, Juniper Networks, Inc.
  • Page 35: Configuring Integrated Photonic Line Card Nodes

    XPN OUT XPN IN expansion module. BEST PRACTICE: Always refer to the PTX3000 Packet Transport Router Hardware Guide when connecting or disconnecting cables on the IPLC modules. See PTX3000 Packet Transport Router Hardware Guide Copyright © 2018, Juniper Networks, Inc.
  • Page 36 Understanding How to Configure the Integrated Photonic Line Card on page 9 Documentation Integrated Photonic Line Card Base and Expansion Module Overview on page 3 Understanding the Integrated Photonic Line Card Architecture on page 6 Copyright © 2018, Juniper Networks, Inc.
  • Page 37: Configuring A Two-Degree Node For Express Traffic

    [edit] user@host# set chassis fpc slot optical-options express-in fpc slot For example, if the second IPLC base module resides in slot 2 and the first IPLC base module resides in slot 1: Copyright © 2018, Juniper Networks, Inc.
  • Page 38: Ports

    Configuring Wavelengths on the Integrated Photonic Line Card Add and Drop Ports To configure the IPLC to add or drop a specific wavelength: Specify the slot location of the IPLC module and access the IPLC configuration hierarchy. Copyright © 2018, Juniper Networks, Inc.
  • Page 39 Remote Optical Interfaces on page 29 Bypassing a Wavelength on page 25 Integrated Photonic Line Card Base and Expansion Module Overview on page 3 Understanding the Integrated Photonic Line Card Architecture on page 6 Copyright © 2018, Juniper Networks, Inc.
  • Page 40 PTX3000 Integrated Photonic Line System Feature Guide Copyright © 2018, Juniper Networks, Inc.
  • Page 41: Configuring And Managing Express Traffic On Two-Degree Iplc Nodes

    For example, to bypass wavelength 1532.29 on the IPLC in slot 1: [edit ] user@host# set chassis fpc 1 optical-options wavelength 1532.29 wss-express-in Verify that the configuration is correct. For example: [edit chassis fpc 1 optical-options] Copyright © 2018, Juniper Networks, Inc.
  • Page 42 Configuring the Integrated Photonic Line Card to Switch Wavelengths to Local or Remote Optical Interfaces on page 29 Integrated Photonic Line Card Base and Expansion Module Overview on page 3 Understanding the Integrated Photonic Line Card Architecture on page 6 Copyright © 2018, Juniper Networks, Inc.
  • Page 43: Remote Chassis

    Specify the slot of the local IPLC module and access the IPLC configuration hierarchy. [edit] user@host# edit chassis fpc slot optical-options For example, if the IPLC base module resides in slot 1: [edit] user@host# edit chassis fpc 1 optical-options Copyright © 2018, Juniper Networks, Inc.
  • Page 44: Switching A Wavelength To An Optical Interface On A Remote Chassis

    IPLC. See Configuring the 10-Gigabit or 100-Gigabit Ethernet DWDM Interface Wavelength Install the IPLC module at the remote location and connect the ports DROP to the respective remote optical interfaces. Copyright © 2018, Juniper Networks, Inc.
  • Page 45: Configuring The Integrated Photonic Line Card To Switch Wavelengths To Local Or Remote Optical Interfaces

    IPLC base module. Line OUT The remote IPLC base module receives the signal on the port and demultiplexes Line IN the wavelengths to the DROP ports on the front panel of the IPLC according to the Copyright © 2018, Juniper Networks, Inc.
  • Page 46: Switching A Wavelength To An Optical Interface In The Same Chassis

    1 optical-options Specify the wavelength number and the name of the physical optical interface to which you want to switch the wavelength. [edit chassis fpc 1 optical-options] user@host# set wavelength switch interface-name Copyright © 2018, Juniper Networks, Inc.
  • Page 47: Switching A Wavelength To An Optical Interface On A Remote Chassis

    To configure the IPLC to switch a wavelength to an optical interface on a remote chassis: Specify the slot of the local IPLC module and access the IPLC configuration hierarchy. [edit] Copyright © 2018, Juniper Networks, Inc.
  • Page 48 Integrated Photonic Line Card Base and Expansion Module Overview on page 3 Documentation Understanding the Integrated Photonic Line Card Architecture on page 6 Understanding How to Configure the Integrated Photonic Line Card on page 9 Bypassing a Wavelength on page 25 Copyright © 2018, Juniper Networks, Inc.
  • Page 49: Configuring The Optical Supervisory Channel In The Amplifier Chain When Using The Optical Inline Amplifier

    IPLC. If you are using Juniper Networks optical inline amplifiers (ILA)s in the amplifier chain, this automated control is extend to the entire amplifier chain. This procedure describes how to configure the OSC on both the PTX3000 integrated photonic line system and the optical ILA.
  • Page 50: Configuring The Anchor Iplc Of The Amplifier Chain

    Specify the slot in which the IPLC resides and access the IPLC amplifier chain configuration hierarchy. [edit] user@host# edit chassis fpc fpc-slot optical-options amplifier-chain For example: [edit] user@host# edit chassis fpc 3 optical-options amplifier-chain Copyright © 2018, Juniper Networks, Inc.
  • Page 51: Configuring The Ip Address Of The Anchor Iplc

    To configure the IP address of the IPLC OSC management interface: Specify the slot in which the IPLC resides and access the IPLC amplifier chain configuration hierarchy. [edit] user@host# edit chassis fpc fpc-slot optical-options amplifier-chain For example: Copyright © 2018, Juniper Networks, Inc.
  • Page 52: Configuring The Mac Address Of The Anchor Iplc

    Specify the slot in which the IPLC resides and access the IPLC amplifier chain configuration hierarchy. [edit] user@host# edit chassis fpc fpc-slot optical-options amplifier-chain For example: [edit] user@host# edit chassis fpc 3 optical-options amplifier-chain Copyright © 2018, Juniper Networks, Inc.
  • Page 53: Configuring The Optical Ila Identification Number

    Configure the IPLC anchor for the amplifier chain, see “Configuring the Anchor IPLC of the Amplifier Chain” on page Configure the IP address of the anchor IPLC. See, “Configuring the IP Address of the Anchor IPLC” on page Copyright © 2018, Juniper Networks, Inc.
  • Page 54 Configuring the Optical Supervisory Channel Across the Amplifier Chain of the PTX3000 Integrated Photonic Line System on page 33 Example: Configuring the Optical Supervisory Channel for the Integrated Photonic Line System and Optical Inline Amplifier on page 73 Copyright © 2018, Juniper Networks, Inc.
  • Page 55: Configuring The Ip Address Of An Optical Inline Amplifier

    For example: [edit] user@host# edit chassis fpc 3 optical-options amplifier-chain Specify the IP address for the optical ILA interface. [edit chassis fpc 3 optical-options amplifier-chain] user@host# set ila 1 ila-options ila-ipv4-address 10.0.0.11/24 Copyright © 2018, Juniper Networks, Inc.
  • Page 56: Configuring Optical Ila Authentication Through The Junos Os Cli

    3 optical-options amplifier-chain ila 0 ila-options ila-user admin Specify the password for the optical ILA. [edit] user@host# set chassis fpc 3 optical-options amplifier-chain ila 0 ila-options ila-password $ABC123 Commit your configuration. [edit] user@host# commit Copyright © 2018, Juniper Networks, Inc.
  • Page 57: Upgrading The Optical Inline Amplifier From The Junos Os Cli

    Upgrading the Optical Inline Amplifier from the Junos OS CLI on page 41 Upgrading the Optical Inline Amplifier from the Junos OS CLI Starting with Junos OS Release 17.1R1, you can upgrade Juniper Networks optical inline amplifiers (ILA)s using the Junos OS CLI. This topic describes how to upgrade optical ILAs in the amplifier chain of the PTX3000 integrated photonic line system.
  • Page 58 Firmware Upgrade Status (none/in progress/done) Status: Successful Percent: Reset the optical ILA. user@router# run request chassis fpc optical-module amplifier-chain ila soft-reset fpc-slot 5 ila-number 2 Reset command was successfully issued to the requested ILA Copyright © 2018, Juniper Networks, Inc.
  • Page 59 Percent: 100 Related Understanding Optical Supervisory Channel Communication in the Amplifier Chain on Documentation page 11 Configuring the Optical Supervisory Channel Across the Amplifier Chain of the PTX3000 Integrated Photonic Line System on page 33 Copyright © 2018, Juniper Networks, Inc.
  • Page 60 PTX3000 Integrated Photonic Line System Feature Guide Copyright © 2018, Juniper Networks, Inc.
  • Page 61: Configuring Performance Monitor Thresholds

    The IPLC supports the performance monitors listed in Table 4 on page Table 4: IPLC Optical Performance Monitors Performance Monitor 15 Min Bin 24 Hr Bin TCA High TCA Low OSC TX power OSC RX power Copyright © 2018, Juniper Networks, Inc.
  • Page 62: Table 5: Iplc Threshold Crossing Alert Minimum And Maximum Values

    400 mW edfa1-awg-low-tca Ingress EDFA pump AWG low TCA 5/15 mW 5 mW edfa1-express-high-tca Ingress EDFA pump express high TCA 390/440 mW 400 mW edfa1-express-low-tca Ingress EDFA pump express low TCA 5/15 mW 5 mW Copyright © 2018, Juniper Networks, Inc.
  • Page 63 400 mW edfa2-awg-low-tca Egress EDFA pump AWG low TCA 5/15 mW 5 mW edfa2-express-high-tca Egress EDFA pump express high TCA 390/440 mW 400 mW edfa2-express-low-tca Egress EDFA pump express low TCA 5/15 mW 5 mW Copyright © 2018, Juniper Networks, Inc.
  • Page 64 —36 dBm Line OUT Variable Optical Attenuation (VOA) lout-voa-high-tca LOUT VOA high TCA 16/25 dBm 17 dBm lout-voa-low-tca LOUT VOA low TCA Optical Channel Monitor (OCM) Power Readings (64 channels x 1 Monitoring Points) Copyright © 2018, Juniper Networks, Inc.
  • Page 65 OSC RX power low TCA —47/—46 dBm —46 dBm Optical Supervisory Channel (OSC) TX Power osc-tx-power-high-tca OSC TX power high TCA 0.5 dBm 5.5/7 dBm 6 dBm osc-tx-power-low-tca OSC TX power low TCA —2/-0.5 dBm —1 dBm Copyright © 2018, Juniper Networks, Inc.
  • Page 66 7; osc-rx-power-low-tca { enable-tca; threshold -46; threshold-24hrs -46; Save your configuration. [edit chassis fpc 2 optical-options tca] user@host# commit You can use the following commands to view information about performance monitors and TCA alarms: Copyright © 2018, Juniper Networks, Inc.
  • Page 67: Enabling And Configuring Thresholds On The Optical Inline Amplifier Performance

    You can enable the TCA that you want monitor. You can keep the default threshold settings or change the settings.This topic describes how to configure TCAs for the optical ILA performance monitors. NOTE: By default, TCAs are disabled. Copyright © 2018, Juniper Networks, Inc.
  • Page 68: Table 6: Optical Ila Performance Monitors

    EDFA Signal output power (for both EDFAs) EDFA Pump current (for both EDFAs) EDFA Pump temperature (for both EDFAs) Each performance monitor supports: 15-minute and 24-hour binning Low and high threshold levels as described in Table 7 on page Copyright © 2018, Juniper Networks, Inc.
  • Page 69: Table 7: Optical Ila Threshold Crossing Alert Minimum And Maximum

    Erbium-Doped Fiber Amplifier (EDFA) Output Power (for Both EDFAs) edfa-ab-output-power EDFA Output power (for both EDFAs) 21/—13 dBm edfa-ba-output-power edfa-ab-pump0-temperature EDFA Pump temperature (for both EDFAs, 2 pumps 30/20 Degrees C per direction) edfa-ba-pump0-temperature edfa-ab-pump1-temperature edfa-ba-pump1-temperature Copyright © 2018, Juniper Networks, Inc.
  • Page 70 Line OUT Variable Optical Attenuation (VOA) —1/26 dB voa-b-attenuation Optical Supervisory Channel (OSC)/FPGA Estimated Fiber Loss osc-a-estimated-fiber-loss OSC/FPGA estimated fiber loss —1/36 dB osc-b-estimated-fiber-loss Optical Supervisory Channel (OSC) RX Power osc-rx-a-power-high-tca OSC RX power 2/—45 dBm osc-rx-b-power-low-tca Copyright © 2018, Juniper Networks, Inc.
  • Page 71 Configure the 24-hour, high threshold. For example: [edit chassis fpc 2 optical-options amplifier-chain ila 3 ila-options] user@host# set osc-a-tx-power-high-tca threshold-24hrs 5 enable-tca Verify the configuration. [edit chassis fpc 2 optical-options amplifier-chain ila 3 ila-options] Copyright © 2018, Juniper Networks, Inc.
  • Page 72 Monitors on page 45 Understanding Optical Supervisory Channel Communication in the Amplifier Chain on page 11 Configuring the Optical Supervisory Channel Across the Amplifier Chain of the PTX3000 Integrated Photonic Line System on page 33 Copyright © 2018, Juniper Networks, Inc.
  • Page 73: Example Configurations

    PART 3 Example Configurations Example: Configuring the PTX3000 Integrated Photonic Line System in a Metro Linear Packet Optical Network on page 59 Example: Configuring the Optical Supervisory Channel on page 73 Copyright © 2018, Juniper Networks, Inc.
  • Page 74 PTX3000 Integrated Photonic Line System Feature Guide Copyright © 2018, Juniper Networks, Inc.
  • Page 75: Example: Configuring The Ptx3000 Integrated Photonic Line System In A Metro Linear Packet Optical Network

    For complete information on all PTX Series Packet Transport Routers hardware components, see PTX Series Packet Transport Routers For complete information on all PTX Series Packet Transport Routers software features, Junos OS for PTX Series Packet Transport Routers, Release 15.1 Copyright © 2018, Juniper Networks, Inc.
  • Page 76: Figure 5: Iplc In Metro Linear Packet Optical Deployment

    PT IN PT OUT IPLC PT OUT PT IN IPLC FPC 3 FPC 2 Add/Drop ports 1561.01 1556.15 1561.01 1556.15 1560.20 1556.96 1560.20 1554.54 et-6/0/0 et-6/0/1 et-8/0/2 et-6/0/2 PIC/MIC et-8/0/03 et-8/0/4 PTX3000 Node B Copyright © 2018, Juniper Networks, Inc.
  • Page 77 ILAs between the three IPLC nodes. On Node B, connect the two IPLC modules together using the ports PT IN PT OUT on the front panel of the IPLC as shown in Figure 5 on page Copyright © 2018, Juniper Networks, Inc.
  • Page 78: Table 8: Example Configuration Summary

    Port: 6 Port: 6 Mode: switch Mode: Mode: switch wss-express-in (bypass) Slot: 3 Port: 6 Mode: (bypass) wss-express-in 1556.96 et-12/0/2 Slot: 1 et-8/0/3 Slot: 3 — — Port: 5 Port: 5 Mode: switch Mode: switch Copyright © 2018, Juniper Networks, Inc.
  • Page 79 Configuring the IPLC Base Module at Node A on page 64 Configuring the Two IPLC Base Modules at Node B on page 66 Configuring the IPLC Base Module at Node C on page 69 Results on page ? Copyright © 2018, Juniper Networks, Inc.
  • Page 80 Configure wavelength 1560.20 on port 1 of the IPLC base module to be switched to optical interface et-12/0/1. [edit chassis fpc 1 optical-options] user@host# set wavelength 1560.20 switch et-12/0/1 Configure wavelength 1556.96 on port 5 of the IPLC base module to be switched to optical interface et-12/0/2. Copyright © 2018, Juniper Networks, Inc.
  • Page 81 1556.15 { switch { et-12/0/3; wavelength 1556.96 { switch { et-12/0/2; wavelength 1560.20 { switch { et-12/0/1; wavelength 1561.01 { switch { et-12/0/0; If you are done configuring the device, enter commit from configuration mode. Copyright © 2018, Juniper Networks, Inc.
  • Page 82 [edit chassis fpc 2 optical-options] user@host# set wavelength 1554.54 switch et-8/0/4 Configure wavelength 1556.15 on port 6 of the IPLC base module in slot 2 to be bypassed: [edit chassis fpc 2 optical-options] user@host# set wavelength 1556.15 wss-express-in Copyright © 2018, Juniper Networks, Inc.
  • Page 83 Confirm the configuration of the IPLC module located in slot 2 of Node B. If the command output does not display the intended configuration, repeat the instructions in this procedure to correct the configuration. [edit chassis fpc 2 optical-options] Copyright © 2018, Juniper Networks, Inc.
  • Page 84 [edit chassis fpc 3 optical-options] user@host# show wavelength 1556.15 { wss-express-in; wavelength 1556.96 { switch { et-8/0/3; wavelength 1560.20 { switch { et-8/0/2; wavelength 1561.01 { switch { et-6/0/0; express-in { fpc { Copyright © 2018, Juniper Networks, Inc.
  • Page 85 Confirm the configuration of the IPLC module located in slot 8 of Node C. If the command output does not display the intended configuration, repeat the instructions in this procedure to correct the configuration. [edit chassis fpc 8 optical-options] Copyright © 2018, Juniper Networks, Inc.
  • Page 86 Verify the topology of each IPLC node. For example, at IPLC Node A, enter the following. user@host>show chassis fpc optical-properties topology detail fpc-slot 1 IPLC Topology Information Wavelength(nm) / Port / Frequency(THz) State Connected Copyright © 2018, Juniper Networks, Inc.
  • Page 87 Wavelength 1556.96 is switched to optical interface et-12/0/2 Wavelength 1556.16 is switched to optical interface et-12/0/3 This matches what is listed in Table 8 on page 62 for Node A and confirms the configuration is operating correctly. Copyright © 2018, Juniper Networks, Inc.
  • Page 88 Understanding the Integrated Photonic Line Card Architecture on page 6 Configuring Wavelengths on the Integrated Photonic Line Card Add and Drop Ports on page 22 Configuring a Two-Degree Node for Express Traffic on page 21 Copyright © 2018, Juniper Networks, Inc.
  • Page 89: Example: Configuring The Optical Supervisory Channel

    This example shows you how to configure optical supervisory channel (OSC) communication across the PTX3000 integrated photonic line system when you are using the Juniper Networks optical ILA in the amplifier chain. Requirements on page 73 Overview on page 73...
  • Page 90: Figure 6: Example Topology And Configuration

    To quickly configure this example, copy the following commands, paste them into a text Configuration file, remove any line breaks, change any details necessary to match your network configuration, and then copy and paste the commands into the CLI at the [edit] hierarchy level. Copyright © 2018, Juniper Networks, Inc.
  • Page 91 To configure the PTX3000 integrated photonic line system at Site A and the optical ILAs in the amplifier chain: Configure the anchor IPLC. [edit chassis fpc 3 optical-options amplifier-chain] set anchor-iplc set osc-ip 10.0.0.10/24 set osc-mac aa:bb:cc:dd:ee:ff Copyright © 2018, Juniper Networks, Inc.
  • Page 92 10.0.0.10/24; osc-mac aa:bb:cc:dd:ee:ff; ila 0 { ila-options { ila-ipv4-address 10.0.0.11/24; edfa-a-b { tca-input-power-high { enable-tca; threshold 2; tca-pump1-temperature-low { enable-tca; threshold 19; tca-pump1-temperature-low { threshold 19; tca-pump1-temperature-high { threshold 31; osc-a { osc-tx-power-high-tca { Copyright © 2018, Juniper Networks, Inc.
  • Page 93 { enable-tca; threshold 20; osc-a { osc-tx-power-high-tca { enable-tca; threshold 4; ila 2 { ila-options { ila-ipv4-address 10.0.0.13/24; osc-a { osc-tx-power-high-tca { enable-tca; threshold 4; If the configuration is correct, save it. user@host# commit Copyright © 2018, Juniper Networks, Inc.
  • Page 94 Display the IPLC and optical ILA basic information for the complete amplifier chain including the • Display the IP addresses, names, reachability, and connection status for the anchor IPLC Anchor IPLC and OSC IP address Copyright © 2018, Juniper Networks, Inc.
  • Page 95 ILAs show are reachable indicating OSC communications are functioning properly. Related Understanding Optical Supervisory Channel Communication in the Amplifier Chain on Documentation page 11 Configuring the Optical Supervisory Channel Across the Amplifier Chain of the PTX3000 Integrated Photonic Line System on page 33 Copyright © 2018, Juniper Networks, Inc.
  • Page 96 PTX3000 Integrated Photonic Line System Feature Guide Copyright © 2018, Juniper Networks, Inc.
  • Page 97: Troubleshooting And Maintenance

    (Optional), To enable the erbium-doped fiber amplifiers on the IPLC. [edit chassis fpc 2 optical-options] user@host# set no-disable-edfa (Optional), To disable the erbium-doped fiber amplifiers on the IPLC. [edit chassis fpc 2 optical-options] user@host# set disable-edfa Copyright © 2018, Juniper Networks, Inc.
  • Page 98: Enabling Or Disabling The Optical Supervisory Channel Laser

    (Optional), To enable the optical supervisory channel laser. [edit chassis fpc 2 optical-options] user@host# set no-disable-osc (Optional), To disable the optical supervisory channel laser. [edit chassis fpc 2 optical-options] user@host# set disable-osc Confirm the configuration. [edit chassis fpc 2 optical-options] Copyright © 2018, Juniper Networks, Inc.
  • Page 99: Resetting An Optical Inline Amplifier Through The Junos Os Cli

    Whether you perform a soft or hard reset, verify that the Junos OS CLI responds with the following message. Reset command was successfully issued to the requested ILA Verify that the reset is complete and the software is now running. Copyright © 2018, Juniper Networks, Inc.
  • Page 100 Up Time Related Understanding Optical Supervisory Channel Communication in the Amplifier Chain on Documentation page 11 Configuring the Optical Supervisory Channel Across the Amplifier Chain of the PTX3000 Integrated Photonic Line System on page 33 Copyright © 2018, Juniper Networks, Inc.
  • Page 101: Configuration Statements And Operational Commands

    PART 4 Configuration Statements and Operational Commands Configuration Statements on page 87 Operational Commands on page 117 Copyright © 2018, Juniper Networks, Inc.
  • Page 102 PTX3000 Integrated Photonic Line System Feature Guide Copyright © 2018, Juniper Networks, Inc.
  • Page 103: Configuration Statements

    (M320, T320, T640 and PTX Series Routers) on page 94 ila-options on page 96 optical-options (IPLC) on page 100 switch (IPLC) on page 102 tca (IPLC) on page 104 wavelength (IPLC) on page 110 wss-express-in (IPLC) on page 115 Copyright © 2018, Juniper Networks, Inc.
  • Page 104: Amplifier-Chain (Iplc)

    OSC communications over the amplifier chain of the PTX3000 integrated photonic line system. You must specify the following options in order to enable OSC communication, which enables you to configure and manage Juniper Networks optical inline amplifier through the Junos OS CLI: anchor-iplc—Configure the specified IPLC as the anchor IPLC for the optical supervisory...
  • Page 105 Example: Configuring the Optical Supervisory Channel for the Integrated Photonic Line System and Optical Inline Amplifier on page 73 Configuring the Anchor IPLC of the Amplifier Chain on page 34 Configuring the IP Address of the Anchor IPLC on page 35 Copyright © 2018, Juniper Networks, Inc.
  • Page 106: Expansion-Card (Iplc)

    Range: 0 through 15 Default: None Example If the IPLC base module resides in slot 1 and the IPLC expansion module resides in slot [edit] user@host# set chassis fpc 1 optical-options expansion-card fpc 2 Copyright © 2018, Juniper Networks, Inc.
  • Page 107 Integrated Photonic Line Card Base and Expansion Module Overview on page 3 Documentation Understanding the Integrated Photonic Line Card Architecture on page 6 Increasing the Channel Capacity of the Node on page 19 Configuring a Two-Degree Node for Express Traffic on page 21 Copyright © 2018, Juniper Networks, Inc.
  • Page 108: Express-In (Iplc)

    To create a logical connection between the IPLC base modules in slots 1 and 2: [edit] user@host# set chassis fpc 1 optical-options express-in fpc 2 Required Privilege interface—To view this statement in the configuration. Level interface-control—To add this statement to the configuration. Copyright © 2018, Juniper Networks, Inc.
  • Page 109 Integrated Photonic Line Card Base and Expansion Module Overview on page 3 Understanding the Integrated Photonic Line Card Architecture on page 6 Configuring the Integrated Photonic Line Card to Switch Wavelengths to Local or Remote Optical Interfaces on page 29 Copyright © 2018, Juniper Networks, Inc.
  • Page 110: Fpc (M320, T320, T640 And Ptx Series Routers)

    (8 | 4); no-concatenate; q-pic-large-buffer (large-scale | small-scale); Hierarchy Level [edit chassis] Release Information Statement introduced before Junos OS Release 7.4. Error statement introduced for PTX Series routers in Junos OS Release 13.3. Copyright © 2018, Juniper Networks, Inc.
  • Page 111 Related Configuring the Junos OS to Enable SONET/SDH Framing for SONET/SDH PICs Documentation Configuring the Junos OS to Enable a SONET PIC to Operate in Channelized (Multiplexed) Mode Configuring FPC Error Levels and Actions Copyright © 2018, Juniper Networks, Inc.
  • Page 112: Ila-Options

    All communication to and from an optical ILA is through the anchor IPLC in the PTX3000 integrated photonic line system, therefore when you set the IP address of an optical ILA, you must also specify the FPC Copyright © 2018, Juniper Networks, Inc.
  • Page 113 IPLC resides. In addition, be sure to specify an IP address on the same subnet as the anchor IPLC. NOTE: All IP addresses associated with the OSC in the optical amplifier chain must be on the same subnet. Copyright © 2018, Juniper Networks, Inc.
  • Page 114: Table 9: Optical Ila Edfa Threshold Crossing Alerts

    Pump1 temperature low TCA tca-signal-output-power-high Signal output Power high TCA tca-signal-output-power-low Signal output Power low TCA Table 10 on page 99 describes the TCAs you can configure for the optical ILA OSC TCAs: Copyright © 2018, Juniper Networks, Inc.
  • Page 115: Table 10: Optical Ila Osc Threshold Crossing Alerts

    Configuring the Optical Supervisory Channel Across the Amplifier Chain of the PTX3000 Integrated Photonic Line System on page 33 Configuring the IP Address of an Optical Inline Amplifier on page 39 Enabling and Configuring Thresholds on the Optical Inline Amplifier Performance Monitors on page 51 Copyright © 2018, Juniper Networks, Inc.
  • Page 116: Optical-Options (Iplc)

    IPLC. By default, both erbium-doped fiber amplifiers are enabled. no-disable-osc—Enable the optical supervisory channel. By default, the optical supervisory channel is enabled. Copyright © 2018, Juniper Networks, Inc.
  • Page 117 Understanding How to Configure the Integrated Photonic Line Card on page 9 Documentation Configuring a Two-Degree Node for Express Traffic on page 21 Configuring Wavelengths on the Integrated Photonic Line Card Add and Drop Ports on page 22 Copyright © 2018, Juniper Networks, Inc.
  • Page 118: Switch (Iplc)

    Remote—Specify that the wavelength is to be switched to an optical interface on a remote chassis. Example: Switching To switch wavelength 1550.12 on the local IPLC module in slot 2 to the local et-1/1/0 interface, enter the following: Wavelengths to an Copyright © 2018, Juniper Networks, Inc.
  • Page 119 Remote Optical Interfaces on page 29 Understanding How to Configure the Integrated Photonic Line Card on page 9 Understanding the Integrated Photonic Line Card Architecture on page 6 Configuring a Two-Degree Node for Express Traffic on page 21 Copyright © 2018, Juniper Networks, Inc.
  • Page 120: Tca (Iplc)

    EDFA Signal output power (for both EDFAs) EDFA Pump current (for both EDFAs) OCM power readings (64 channels x 1 monitoring points) Power monitor at ADD port Power monitor at EXPRESS IN port Each performance monitor supports: Copyright © 2018, Juniper Networks, Inc.
  • Page 121 Chapter 11: Configuration Statements 15-minute and 24-hour binning Low and high threshold levels Table 13 on page 106 describes each TCA as well as their default, minimum, maximum, and recommended values. Copyright © 2018, Juniper Networks, Inc.
  • Page 122: Table 13: Iplc Threshold Crossing Alert Minimum And Maximum Values

    11 dBm edfa1-sig-power-low-tca Ingress EDFA signal power low TCA —39/—35 dBm > —36 dBm Erbium-Doped Fiber Amplifier (EDFA) Output Power (for Both EDFAs) edfa2-awg-high-tca Egress EDFA pump AWG high TCA 390/440 mW 400 mW Copyright © 2018, Juniper Networks, Inc.
  • Page 123 10/12 dBm 11 dBm edfa2-sig-power-low-tca Egress EDFA signal power low TCA —39/—35 dBm —36 dBm Line OUT Variable Optical Attenuation (VOA) lout-voa-high-tca LOUT VOA high TCA 16/25 dBm 17 dBm lout-voa-low-tca LOUT VOA low TCA Copyright © 2018, Juniper Networks, Inc.
  • Page 124 Optical Supervisory Channel (OSC) TX Power osc-tx-power-high-tca OSC TX power high TCA 0.5 dBm 5.5/7 dBm 6 dBm osc-tx-power-low-tca OSC TX power low TCA —2/-0.5 dBm —1 dBm Default By default, TCAs are disabled. Copyright © 2018, Juniper Networks, Inc.
  • Page 125 122 show chassis fpc optical-properties status on page 140 Integrated Photonic Line Card Base and Expansion Module Overview on page 3 Understanding the Integrated Photonic Line Card Architecture on page 6 Copyright © 2018, Juniper Networks, Inc.
  • Page 126: Wavelength (Iplc)

    Specify the wavelength in nanometers (nm) that you want to configure on the IPLC port. Options nm—Wavelength in nanometers. It can be one of the following listed for the central wavelength in Table 14 on page 111: Copyright © 2018, Juniper Networks, Inc.
  • Page 127: Table 14: Iplc Port Number, Wavelength, And Frequency Mapping

    1555.75 50/100 GHz 192.75 1555.34 50 GHz 192.8 1554.94 50/100 GHz 192.85 1554.54 50 GHz 192.9 1554.13 50/100 GHz 192.95 1553.73 50 GHz 1553.33 50/100 GHz 193.05 1552.93 50 GHz 193.1 1552.52 50/100 GHz Copyright © 2018, Juniper Networks, Inc.
  • Page 128 1546.92 50/100 GHz 193.85 1546.52 50 GHz 193.9 1546.12 50/100 GHz 193.95 1545.72 50 GHz 1545.32 50/100 GHz 194.05 1544.92 50 GHz 194.1 1544.53 50/100 GHz 194.15 1544.13 50 GHz 194.2 1543.73 50/100 GHz Copyright © 2018, Juniper Networks, Inc.
  • Page 129 1537.40 50/100 GHz 195.05 1537.00 50 GHz 195.10 1536.61 50/100 GHz 195.15 1536.22 50 GHz 195.20 1535.82 50/100 GHz Default: 1550.12 —1550.12 nm, 50/100GHz spacing The remaining statements are explained separately. See CLI Explorer Copyright © 2018, Juniper Networks, Inc.
  • Page 130 PTX3000 Integrated Photonic Line System Feature Guide Required Privilege interface—To view this statement in the configuration. Level interface-control—To add this statement to the configuration. Related switch (IPLC) on page 102 Documentation wss-express-in (IPLC) on page 115 Copyright © 2018, Juniper Networks, Inc.
  • Page 131: Wss-Express-In (Iplc)

    Required Privilege interface—To view this statement in the configuration. Level interface-control—To add this statement to the configuration. Related express-in (IPLC) on page 92 Documentation wavelength (IPLC) on page 110 Bypassing a Wavelength on page 25 Copyright © 2018, Juniper Networks, Inc.
  • Page 132 PTX3000 Integrated Photonic Line System Feature Guide Copyright © 2018, Juniper Networks, Inc.
  • Page 133: Operational Commands

    Copyright © 2018, Juniper Networks, Inc.
  • Page 134: Clear Chassis Fpc Optical-Properties

    118 Output Fields When you enter this command, you are provided feedback on the status of your request. Sample Output clear chassis fpc optical-properties all user@host> clear chassis fpc optical-properties fpc-slot 5 all Copyright © 2018, Juniper Networks, Inc.
  • Page 135: Show Chassis Fpc Optical-Properties Alarms

    The IPLC EDFA has detected temperature failure. IPLC fpc-slot Temperature Failure The IPLC EDFA Output port has detected LOS. IPLC fpc-slot Output LOS The IPLC EDFA Input port has detected LOS. IPLC fpc-slot Input LOS Copyright © 2018, Juniper Networks, Inc.
  • Page 136: Table 16: Show Chassis Fpc Optical-Properties Alarms Output Fields

    Table 16: show chassis fpc optical-properties alarms Output Fields Field Name Field Description Module Component on which the alarm is triggered. Active FPC or PIC slot number where the active alarm is triggered. Alarms Alarm that is triggered. Copyright © 2018, Juniper Networks, Inc.
  • Page 137 IPLC 14 OSC Drop LOS Main Board IPLC 14 Line In LOS Output EDFA IPLC 14 Output LOS Output EDFA IPLC 14 Input LOS Main Board IPLC 14 Firmware Inconsistent Main Board IPLC 14 SFP LOS Copyright © 2018, Juniper Networks, Inc.
  • Page 138: Show Chassis Fpc Optical-Properties Edfa

    EDFA Information INPUT EDFA OUTPUT EDFA Gain Setting Saved (low/high 0.01 dB) 1089/1800 1900 Gain Tilt Setting (mBm) Input LOS Upper Threshold (0.01 dBm) -3300 -100 Input LOS Lower Threshold (0.01 dBm) -3600 -2300 Copyright © 2018, Juniper Networks, Inc.
  • Page 139 Chapter 12: Operational Commands Output LOS Upper Threshold (0.01 dBm) -100 -100 Output LOS Lower Threshold (0.01 dBm) -400 -400 Gain Setting (low/high 0.01 dB) 1089/1800 1900 Output Enable Auto LOS Enable Mode Plim Power -6000 Copyright © 2018, Juniper Networks, Inc.
  • Page 140: Show Chassis Fpc Optical-Properties Mfg-Info

    Display manufacturing details about the optical channel monitor (OCM) Sample Output show chassis fpc optical-properties mfg info user@host> show chassis fpc optical-properties mfg-info fpc-slot 5 Manufacturing Information MAIN BOARD EDFA Product Name IPLC EDFA Copyright © 2018, Juniper Networks, Inc.
  • Page 141 2.01 2.01 3.00 2.01 PCB Revision 2.01 2.01 3.00 2.01 Part Number RADMADM2D0JUP01 RADMADM2D0JUP01-2 DWDM21WSS5OPL01 OCMM0G2192JUP01 Serial Number 3DI05490003 B5845436 b3675577 B5690792 Manufacturing Date 2015-12-03 2015-11-10 2015-07-08 2015-09-30 Calibration Date 2015-12-03 2015-11-10 2015-08-08 2015-10-10 Copyright © 2018, Juniper Networks, Inc.
  • Page 142: Show Chassis Fpc Optical-Properties Ocm

    5 OCM Power Information Wavelength(nm) / Port / Frequency(THz) Line Out(OCM2)(0.01 dBm) 1561.01 192.05 -6000 1560.20 192.15 -6000 1559.39 192.25 -6000 1558.58 192.35 -6000 1557.77 192.45 -6000 Copyright © 2018, Juniper Networks, Inc.
  • Page 143 -6000 1544.13 194.15 -6000 1543.33 194.25 -6000 1542.54 194.35 -6000 1541.75 194.45 -6000 1540.95 194.55 -6000 1540.16 194.65 -6000 1539.37 194.75 -6000 1538.58 194.85 -6000 1537.79 194.95 -6000 1537.00 195.05 -6000 1536.22 195.15 -6000 Copyright © 2018, Juniper Networks, Inc.
  • Page 144: Show Chassis Fpc Optical-Properties Pm-Current

    Threshold value set for the minimum and maximum values TCA-ENABLED (MIN) (MAX) Threshold-crossing alert (TCA) set for the minimum and maximum values. TCA is enabled. TCA-RAISED (MIN) (MAX) TCA raised for the minimum and maximum values. : TCA crosses the threshold. Copyright © 2018, Juniper Networks, Inc.
  • Page 145 -6000 -6000 -6000 -6000 1557.77 -6000 -6000 -6000 -6000 1556.96 -6000 -6000 -6000 -6000 1556.15 -6000 -6000 -6000 -6000 1555.34 -6000 -6000 -6000 -6000 1554.54 -6000 -6000 -6000 -6000 1553.73 -6000 -6000 -6000 -6000 Copyright © 2018, Juniper Networks, Inc.
  • Page 146 -6000 -6000 -6000 -6000 1540.16 -6000 -6000 -6000 -6000 1539.37 -6000 -6000 -6000 -6000 1538.58 -6000 -6000 -6000 -6000 1537.79 -6000 -6000 -6000 -6000 1537.00 -6000 -6000 -6000 -6000 1536.22 -6000 -6000 -6000 -6000 Copyright © 2018, Juniper Networks, Inc.
  • Page 147: Show Chassis Fpc Optical-Properties Pm-Currentday

    Threshold value set for the minimum and maximum values. TCA-ENABLED (MIN) (MAX) Threshold-crossing alert (TCA) set for the minimum and maximum values. TCA is enabled. TCA-RAISED (MIN) (MAX) TCA raised for the minimum and maximum values. : TCA crosses the threshold. Copyright © 2018, Juniper Networks, Inc.
  • Page 148 -6000 -6000 1559.39 -6000 -6000 -6000 1558.58 -6000 -6000 -6000 1557.77 -6000 -6000 -6000 1556.96 -6000 -6000 -6000 1556.15 -6000 -6000 -6000 1555.34 -6000 -6000 -6000 1554.54 -6000 -6000 -6000 1553.73 -6000 -6000 -6000 Copyright © 2018, Juniper Networks, Inc.
  • Page 149 -6000 -6000 1541.75 -6000 -6000 -6000 1540.95 -6000 -6000 -6000 1540.16 -6000 -6000 -6000 1539.37 -6000 -6000 -6000 1538.58 -6000 -6000 -6000 1537.79 -6000 -6000 -6000 1537.00 -6000 -6000 -6000 1536.22 -6000 -6000 -6000 Copyright © 2018, Juniper Networks, Inc.
  • Page 150: Show Chassis Fpc Optical-Properties Pm-Interval

    Threshold value set for the minimum and maximum values. TCA-ENABLED (MIN) (MAX) Threshold crossing alert (TCA) set for the minimum and maximum values. TCA is enabled. TCA-RAISED (MIN) (MAX) TCA raised for the minimum and maximum values. : TCA crosses the threshold. Copyright © 2018, Juniper Networks, Inc.
  • Page 151 -6000 -6000 1559.39 -6000 -6000 -6000 1558.58 -6000 -6000 -6000 1557.77 -6000 -6000 -6000 1556.96 -6000 -6000 -6000 1556.15 -6000 -6000 -6000 1555.34 -6000 -6000 -6000 1554.54 -6000 -6000 -6000 1553.73 -6000 -6000 -6000 Copyright © 2018, Juniper Networks, Inc.
  • Page 152 1541.75 -6000 -6000 -6000 1540.95 -6000 -6000 -6000 1540.16 -6000 -6000 -6000 1539.37 -6000 -6000 -6000 1538.58 -6000 -6000 -6000 1537.79 -6000 -6000 -6000 1537.00 -6000 -6000 -6000 1536.22 -6000 -6000 -6000 ... truncated Copyright © 2018, Juniper Networks, Inc.
  • Page 153: Show Chassis Fpc Optical-Properties Pm-Previousday

    Threshold value set for the minimum and maximum values. TCA-ENABLED (MIN) (MAX) Threshold-crossing alert (TCA)set for the minimum and maximum values. TCA is enabled. TCA-RAISED (MIN) (MAX) TCA raised for the minimum and maximum values. : TCA crosses the threshold. Copyright © 2018, Juniper Networks, Inc.
  • Page 154 OCM Power (LOUT)(0.01 dBm) 1561.01 -6000 -5953 1560.20 -6000 -5953 1559.39 -6000 -5953 1558.58 -6000 -5953 1557.77 -6000 -5953 1556.96 -6000 -5953 1556.15 -6000 -5953 1555.34 -6000 -5953 1554.54 -6000 -5953 1553.73 -6000 -5953 Copyright © 2018, Juniper Networks, Inc.
  • Page 155 -5953 1544.13 -6000 -5953 1543.33 -6000 -5953 1542.54 -6000 -5953 1541.75 -6000 -5953 1540.95 -6000 -5953 1540.16 -6000 -5953 1539.37 -6000 -5953 1538.58 -6000 -5953 1537.79 -6000 -5953 1537.00 -6000 -5953 1536.22 -6000 -5953 Copyright © 2018, Juniper Networks, Inc.
  • Page 156: Show Chassis Fpc Optical-Properties Status

    Display the power supply voltage reading for the wavelength-selective switch (WSS). WSS Temperature Display the temperature reading for the WSS. OCM Temperature Display the temperature reading for the optical channel monitor (OCM). OSC Status Display whether the OSC is enabled or disabled. Copyright © 2018, Juniper Networks, Inc.
  • Page 157 29.9 degrees C Output EDFA Pump Temperature 25.6 degrees C Output EDFA Coil Temperature 53.3 degrees C WSS Power Supply Voltage (0.01 V) WSS Temperature 32.2 degrees C OCM Temperature 29.9 degrees C OSC Status Copyright © 2018, Juniper Networks, Inc.
  • Page 158: Show Chassis Fpc Optical-Properties Topology

    Expansion Port: Slot number of the connected IPLC expansion module. Wavelength Port: For the Switch state: Name of the interface to which it is connected. For the Express-In state: IPLC to which it is connected. Copyright © 2018, Juniper Networks, Inc.
  • Page 159 5 IPLC Topology Information Wavelength(nm) / Port / Frequency(THz) State Connected To Express-in Port DOWN Expansion Port DOWN 1548.91 193.55 AWG Add et-12/0/0 Copyright © 2018, Juniper Networks, Inc.
  • Page 160: Show Chassis Hardware

    <lcc number | scc> Syntax (TX Matrix Plus show chassis hardware <clei-models> Router) <detail | extensive> <models> <lcc number | sfc number> Syntax (MX Series show chassis hardware <detail | extensive> Routers) <clei-models> <models> Copyright © 2018, Juniper Networks, Inc.
  • Page 161 Command introduced in Junos OS Release 9.0 for EX Series switches. option introduced in Junos OS Release 9.6 for the TX Matrix Plus router. Command introduced in Junos OS Release 11.1 for QFX Series. Copyright © 2018, Juniper Networks, Inc.
  • Page 162 DC power supply module (PSM) and power distribution unit (PDU) that are added to provide power to the high-density FPC (FPC2-PTX-P1A) and other components in a PTX5000 Packet Transport Router. Copyright © 2018, Juniper Networks, Inc.
  • Page 163 [slot-id slot-id | device-alias alias-name]—(Junos Fusion only) (Optional) Display hardware information for the specified satellite device in a Junos Fusion, or for all satellite devices in the Junos Fusion if no satellite devices are specified. Copyright © 2018, Juniper Networks, Inc.
  • Page 164: Table 26: Routing Engines Displaying Dimm Information

    (EX4500 Switch) on page 160 show chassis hardware detail (EX9200 Switch) on page 161 show chassis hardware detail (EX9251 Switch) on page 161 show chassis hardware detail (EX9253 Switch) on page 162 Copyright © 2018, Juniper Networks, Inc.
  • Page 165 PIC) on page 217 show chassis hardware (MX960 Router) on page 219 show chassis hardware (MX960 Router with Bidirectional Optics) on page 220 show chassis hardware (MX960 Router with Enhanced MX SCB) on page 221 Copyright © 2018, Juniper Networks, Inc.
  • Page 166 Routers with Enhanced 20-Port Gigabit Ethernet MIC) on page 304 show chassis hardware models (MX5, MX10, MX40, MX80, MX240, MX480, and MX960 Routers with Enhanced 20-Port Gigabit Ethernet MIC) on page 304 show chassis hardware (MX2008 Router) on page 305 Copyright © 2018, Juniper Networks, Inc.
  • Page 167 (QFX10008 and QFX10016 Switches) on page 367 show chassis hardware interconnect-device (QFabric Systems) on page 367 show chassis hardware node-device (QFabric Systems) on page 368 show chassis hardware (PTX5000 Packet Transport Router) on page 368 Copyright © 2018, Juniper Networks, Inc.
  • Page 168 (ACX500 Router) on page 384 Output Fields Table 27 on page 153 lists the output fields for the command. show chassis hardware Output fields are listed in the approximate order in which they appear. Copyright © 2018, Juniper Networks, Inc.
  • Page 169: Table 27: Show Chassis Hardware Output Fields

    Control Boards (CBs). Also displays information about Flexible PIC Concentrators (FPCs) and associated Modular Interface Cards (MICs) and Physical Interface Cards (PICs). Revision level of the chassis component. All levels Version Part number of the chassis component. All levels Part number Copyright © 2018, Juniper Networks, Inc.
  • Page 170 All levels Serial number is also the serial number of the router chassis. Use this serial number when you need to contact Juniper Networks Customer Support about the router or switch chassis. keyword only) Identification number that describes the FRU hardware.
  • Page 171 Serial number Description Chassis REV 06 CY0109220035 EX8216 Midplane REV 06 710-016845 BA0909120112 EX8216-MP CB 0 REV 22 710-020771 AX0109197723 EX8216-RE320 CB 1 REV 22 710-020771 AX0109197726 EX8216-RE320 Routing Engine 1 BUILTIN BUILTIN RE-EX8216 Copyright © 2018, Juniper Networks, Inc.
  • Page 172 CX1209140212 EX8216-FT FTC 1 REV 4 760-022620 CX1209140212 EX8216-FT Bottom Fan Tray FTC 0 REV 4 760-022620 CX1209140211 EX8216-FT FTC 1 REV 4 760-022620 CX1209140211 EX8216-FT LCD 0 REV 04 710-025742 CE0109186919 EX8200 LCD Copyright © 2018, Juniper Networks, Inc.
  • Page 173 REV 14 710-013037 T1600-FPC4-ES PIC 0 REV 11 750-017405 PD-4XGE-XFP PIC 1 REV 13 750-017405 PD-4XGE-XFP FPC 7 REV 09 710-007529 T640-FPC3 PIC 0 REV 10 750-012793 PC-1XGE-TYPE3-XFP-IQ2 PIC 1 REV 01 750-015217 PC-8GE-TYPE3-SFP-IQ2 Copyright © 2018, Juniper Networks, Inc.
  • Page 174 FRU model number Midplane REV 24 750-077138 CMMUN00ARA JNP10016 CB 0 REV 04 711-065897 PROTOXCLEI PROTO-ASSEMBLY CB 1 REV 05 711-065897 PROTOXCLEI PROTO-ASSEMBLY FPC 2 PIC 0 BUILTIN FPC 4 REV 35 750-071976 CMUIANABAA JNP10K-LC1101 Copyright © 2018, Juniper Networks, Inc.
  • Page 175 REV 01 740-021309 T09K00695 SFP+-10G-LR Xcvr 1 REV 01 740-030658 AD1146A05JT SFP+-10G-USR Power Supply 0 JPSU-170W-AC show chassis hardware (EX2300 Switch) user@switch> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Copyright © 2018, Juniper Networks, Inc.
  • Page 176 Part number Serial number FRU model number Routing Engine 0 REV 01 750-035700 GG0210271867 EX4500-40F-FB-C FPC 0 REV 01 750-035700 GG0210271867 EX4500-40F-FB-C PIC 0 BUILTIN BUILTIN EX4500-40F-FB-C Power Supply 1 REV 01 740-029654 H884FS00JC09 EX4500-PWR1-AC-FB Copyright © 2018, Juniper Networks, Inc.
  • Page 177 BUILTIN BUILTIN RE-S-2X00x6 CB 0 REV 05 750-069579 CAGT1382 EX9251 FPC 0 BUILTIN BUILTIN PIC 0 BUILTIN BUILTIN 4XQSFP28 PIC Xcvr 0 REV 01 740-044512 APF14500007NHC QSFP+-40G-CU50CM Xcvr 2 REV 01 740-046565 QH21035H QSFP+-40G-SR4 Copyright © 2018, Juniper Networks, Inc.
  • Page 178 CAJF6891 JNP FAN 3RU Fan Tray 3 REV 08 760-069329 CAJF6937 JNP FAN 3RU show chassis hardware detail (PTX10008 Routers) user@switch> show chassis hardware detail Hardware inventory: Item Version Part number Serial number Description Copyright © 2018, Juniper Networks, Inc.
  • Page 179 Xcvr 18 REV 01 740-054050 INFAJ0492237 QSFP+-4X10G-LR Xcvr 26 REV 01 740-058734 1ACQ111803N QSFP-100GBASE-SR4 Xcvr 27 REV 01 740-058734 1ACQ113405S QSFP-100GBASE-SR4 FPC 3 REV 35 750-051357 ACPD2186 LC1101 - 30C / 30Q / 96X Copyright © 2018, Juniper Networks, Inc.
  • Page 180 Hardware inventory: Item Version Part number Serial number Description Chassis DH995 JNP10016 [PTX10016] Midplane REV 22 750-056555 ACPM7810 Midplane 16 Routing Engine 0 BUILTIN BUILTIN RE-PTX-2X00x4 vtbd0 15360 MB Virtio Block Disk Copyright © 2018, Juniper Networks, Inc.
  • Page 181 BUILTIN BUILTIN FPC CPU PIC 0 BUILTIN BUILTIN 30x100GE/30x40GE/96x10GE Xcvr 0 NON-JNPR INGBT7970007 QSFP-100GBASE-LR4 Xcvr 1 NON-JNPR UWQ24D9 QSFP-100GBASE-LR4 Xcvr 2 NON-JNPR INGBT7970011 QSFP-100GBASE-LR4 Xcvr 3 NON-JNPR UX60AF1 QSFP-100G-CWDM4 Xcvr 4 NON-JNPR UX408JJ QSFP-100GBASE-LR4 Copyright © 2018, Juniper Networks, Inc.
  • Page 182 Xcvr 1 REV 01 740-012434 AGT063832LY SFP-SR Xcvr 3 REV 01 740-016064 C06J19018 SFP-LR PIC 2 REV 15 750-014895 DM5757 MultiServices 100 PIC 3 REV 01 750-025390 JW9448 12x T1/E1 CE FPC 1 E-FPC Copyright © 2018, Juniper Networks, Inc.
  • Page 183 S/N AA9704 Host 0 98000004f8f27501 teknor SSB slot 0 REV 01 710-001951 S/N AD5905 Internet Processor II SSRAM bank 0 REV 01 710-001385 S00480 2 MB SSRAM bank 1 REV 01 710-001385 S00490 2 MB Copyright © 2018, Juniper Networks, Inc.
  • Page 184 REV 02 710-000077 S/N AA2270 1 MB SSRAM bank 2 REV 02 710-000077 S/N AA2269 1 MB SSRAM bank 3 REV 02 710-000077 S/N AA2268 1 MB FPC 0 REV 01 710-000175 S/N AA0048 Copyright © 2018, Juniper Networks, Inc.
  • Page 185 4x G/E, 1000 BASE-SX FPC 4 REV 02 710-005078 BE0664 M40e-FPC Type 1 REV 01 710-004600 BD9559 PIC 0 REV 03 750-001894 AG7963 1x G/E, 1000 BASE-SX PIC 2 REV 01 750-002575 AF2472 4x OC-3 SONET, SMIR Copyright © 2018, Juniper Networks, Inc.
  • Page 186 REV 04 710-011663 CJ9386 M120 FEB Fan Tray 0 Front Top Fan Tray Fan Tray 1 Front Bottom Fan Tray Fan Tray 2 Rear Top Fan Tray Fan Tray 3 Rear Bottom Fan Tray Copyright © 2018, Juniper Networks, Inc.
  • Page 187 Front Top Fan Tray Fan Tray 1 Front Bottom Fan Tray Fan Tray 2 Rear Top Fan Tray Fan Tray 3 Rear Bottom Fan Tray show chassis hardware models (M120 Router) user@host> show chassis hardware models Copyright © 2018, Juniper Networks, Inc.
  • Page 188 S/N AB3329 PIC 0 REV 01 1x OC-192 SM SR-2 Fan Tray 0 Rear Bottom Blower Fan Tray 1 Rear Top Blower Fan Tray 2 Front Top Blower Fan Tray 3 Front Fan Tray Copyright © 2018, Juniper Networks, Inc.
  • Page 189 Chassis M160 Midplane REV 02 710-001245 S/N AB4107 FPM CMB REV 01 710-001642 S/N AA2911 FPM Display REV 01 710-001647 S/N AA2999 REV 02 710-001593 S/N AA9563 PEM 0 Rev 01 740-001243 S/N KJ35769 Copyright © 2018, Juniper Networks, Inc.
  • Page 190 (M320 Router) user@host> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis 67245 M320 Midplane REV 05 710-009120 RB1202 M320 Midplane FPM GBUS REV 04 710-005928 HZ5697 M320 Board Copyright © 2018, Juniper Networks, Inc.
  • Page 191 750-005634 PB-1CHOC12SMIR-QPP PIC 1 REV 10 750-005634 PB-1CHOC12SMIR-QPP PIC 2 REV 07 750-005634 PB-1CHOC12SMIR-QPP PIC 3 REV 07 750-005634 PB-1CHOC12SMIR-QPP FPC 3 PIC 0 REV 03 750-001895 PB-1OC12-SON-MM PIC 1 REV 04 750-001894 PB-1GE-SX Copyright © 2018, Juniper Networks, Inc.
  • Page 192 Xcvr 9 REV 01 740-011782 P9M0U37 SFP-SX MIC 1 REV 20 750-028380 ZG2657 3D 2x 10GE XFP PIC 2 BUILTIN BUILTIN 1x 10GE XFP PIC 3 BUILTIN BUILTIN 1x 10GE XFP Fan Tray Fan Tray Copyright © 2018, Juniper Networks, Inc.
  • Page 193 Xcvr 1 REV 01 740-031851 AM1045SU7M9 SFP-SX Xcvr 2 REV 01 740-031851 AM1045SUAPT SFP-SX Xcvr 3 REV 01 740-011613 PFF2BZH SFP-SX Xcvr 4 REV 01 740-031851 AM1045SUDDN SFP-SX Xcvr 5 REV 01 740-031851 AM1039S00ZR SFP-SX Copyright © 2018, Juniper Networks, Inc.
  • Page 194 1x 10GE XFP Xcvr 0 REV 01 740-014289 T07M71094 XFP-10G-SR MIC 1 REV 02 750-028380 JG8548 3D 2x 10GE XFP PIC 2 BUILTIN BUILTIN 1x 10GE XFP Xcvr 0 REV 02 740-014289 T08L86302 XFP-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 195 Xcvr 1 REV 01 740-016068 PJL7A6G SFP-SR Xcvr 2 REV 01 740-016068 PJL7A5J SFP-SR Xcvr 3 REV 01 740-016065 PJN5HPZ SFP-SR Xcvr 4 REV 01 740-029122 PKB38TL SFP-LR Xcvr 5 REV 01 740-011787 P6A107G SFP-LR Copyright © 2018, Juniper Networks, Inc.
  • Page 196 (MX480 Packet Transport Router with details of virtual disk size) user@host> show chassis hardware detail Hardware inventory: Item Version Part number Serial number Description Chassis JN122FFD9AFB MX480 Midplane REV 05 710-017414 ACRB8882 MX480 Midplane FPM Board REV 02 710-017254 CADF7623 Front Panel Display Copyright © 2018, Juniper Networks, Inc.
  • Page 197 Address 0x60: 00 00 00 00 00 00 41 30 30 ff ff ff ff ff ff ff Address 0x70: ff ff ff c2 47 33 35 30 33 00 00 00 00 00 00 00 Copyright © 2018, Juniper Networks, Inc.
  • Page 198 (addr 2) USB2513Bi 9491 SMSC uhub1 usb0 (addr 3) ATP IG eUSB SSD 44801 ATP Electronics umass0 Routing Engine 1 REV 13 750-044228 CAAM6380 RE-MX-104 Jedec Code: 0x7fb0 EEPROM Version: 0x02 P/N: 750-044228 S/N: CAAM6380 Copyright © 2018, Juniper Networks, Inc.
  • Page 199 Address 0x10: 00 00 00 00 42 55 49 4c 54 49 4e 00 4d 58 43 00 Address 0x20: 42 55 49 4c 54 49 4e 00 4d 58 43 00 00 00 00 00 Copyright © 2018, Juniper Networks, Inc.
  • Page 200 EEPROM Version: 0x02 P/N: 750-054097 S/N: ACPD4307 Assembly ID: 0x0be3 Assembly Version: 01.27 Date: 08-08-2016 Assembly Flags: 0x00 Version: REV 27 CLEI Code: CMMUM00ARA ID: QFX10008 Midplane FRU Model Number: QFX10008-CHAS Board Information Record: Copyright © 2018, Juniper Networks, Inc.
  • Page 201 Address 0x70: ff ff ff db ff ff ff ff ff ff ff ff ff ff ff ff FPC 0 REV 36 750-051354 ACNP4679 LC1102 - 12C / 36Q / 144X Jedec Code: 0x7fb0 EEPROM Version: 0x02 Copyright © 2018, Juniper Networks, Inc.
  • Page 202 Xcvr 19 REV 01 740-058734 1ECQ11381JS QSFP-100GBASE-SR4 Xcvr 23 REV 01 740-058734 1ACQ112000E QSFP-100GBASE-SR4 Xcvr 25 REV 01 740-058734 1ECQ11381NT QSFP-100GBASE-SR4 Xcvr 28 REV 01 740-054053 QG1502WV QSFP+-4X10G-SR Xcvr 29 REV 01 740-058734 1ACQ112000D QSFP-100GBASE-SR4 Copyright © 2018, Juniper Networks, Inc.
  • Page 203 QSFP-100GBASE-LR4 Xcvr 25 NON-JNPR GDA2017459 QSFP-100GBASE-LR4 Xcvr 29 NON-JNPR GDF2008750 QSFP-100GBASE-LR4 FPC 2 REV 32 750-051357 ACPB0341 LC1101 - 30C / 30Q / 96X Jedec Code: 0x7fb0 EEPROM Version: 0x02 P/N: 750-051357 S/N: ACPB0341 Copyright © 2018, Juniper Networks, Inc.
  • Page 204 QSFP+-4X10G-LR Xcvr 26 REV 01 740-058734 1ACQ111803N QSFP-100GBASE-SR4 Xcvr 27 REV 01 740-058734 1ACQ113405S QSFP-100GBASE-SR4 FPC 3 REV 35 750-051357 ACPD2186 LC1101 - 30C / 30Q / 96X Jedec Code: 0x7fb0 EEPROM Version: 0x02 Copyright © 2018, Juniper Networks, Inc.
  • Page 205 LC1102 - 12C / 36Q / 144X Jedec Code: 0x7fb0 EEPROM Version: 0x02 P/N: 750-068822 S/N: ACPF0057 Assembly ID: 0x0be7 Assembly Version: 01.08 Date: 09-01-2016 Assembly Flags: 0x00 Version: REV 08 CLEI Code: CMUIAM9BAB Copyright © 2018, Juniper Networks, Inc.
  • Page 206 Address 0x30: e0 ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff Address 0x40: ff ff ff ff 01 43 4d 55 49 41 4d 39 42 41 42 51 Copyright © 2018, Juniper Networks, Inc.
  • Page 207 Assembly Version: 01.07 Date: 07-22-2016 Assembly Flags: 0x00 Version: REV 07 ID: QFX10000 FPD Board Information Record: Address 0x00: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff Copyright © 2018, Juniper Networks, Inc.
  • Page 208 Address 0x40: ff ff ff ff 01 43 4d 55 50 41 44 4e 42 41 41 51 Address 0x50: 46 58 31 30 30 30 30 2d 50 57 52 2d 41 43 00 00 Copyright © 2018, Juniper Networks, Inc.
  • Page 209 Address 0x70: ff ff ff dc ff ff ff ff ff ff ff ff ff ff ff ff FTC 0 REV 14 750-050108 ACPE4038 Fan Controller 8 Jedec Code: 0x7fb0 EEPROM Version: 0x02 P/N: 750-050108 S/N: ACPE4038 Assembly ID: 0x0bee Assembly Version: 01.14 Date: 09-27-2016 Assembly Flags: 0x00 Copyright © 2018, Juniper Networks, Inc.
  • Page 210 Address 0x00: 7f b0 02 ff 0b f0 01 09 52 45 56 20 30 39 00 00 Address 0x10: 00 00 00 00 37 36 30 2d 30 35 34 33 37 32 00 00 Copyright © 2018, Juniper Networks, Inc.
  • Page 211 Address 0x60: 00 00 00 00 00 00 41 45 00 ff ff ff ff ff ff ff Address 0x70: ff ff ff d1 00 00 00 00 00 00 00 00 00 00 00 00 SIB 3 REV 24 750-050058 ACNZ0617 Switch Fabric 8 Copyright © 2018, Juniper Networks, Inc.
  • Page 212 Address 0x70: ff ff ff ce 00 00 00 00 00 00 00 00 00 00 00 00 show chassis hardware extensive (PTX10016 Router) user@host> show chassis hardware extensive Hardware inventory: Item Version Part number Serial number Description Chassis DH995 JNP10016 [PTX10016] Copyright © 2018, Juniper Networks, Inc.
  • Page 213 Address 0x20: 53 2f 4e 20 41 43 50 4c 37 32 33 38 00 0f 03 07 Address 0x30: e1 ff ff ff ad 01 00 10 e8 b6 c2 46 aa 29 ff ff Copyright © 2018, Juniper Networks, Inc.
  • Page 214 Address 0x60: 00 00 00 00 00 00 45 00 00 ff ff ff ff ff ff ff Address 0x70: ff ff ff f3 50 36 36 36 36 00 00 00 00 00 00 00 PIC 0 BUILTIN BUILTIN 12x100GE/36x40GE/144x10GE Jedec Code: 0x7fb0 EEPROM Version: 0x02 P/N: BUILTIN S/N: BUILTIN Copyright © 2018, Juniper Networks, Inc.
  • Page 215 Address 0x00: 7f b0 02 ff f0 50 02 11 00 00 00 00 07 0a 20 45 Address 0x10: 6c 61 70 73 42 55 49 4c 54 49 4e 00 25 73 3a 20 Copyright © 2018, Juniper Networks, Inc.
  • Page 216 Address 0x60: 00 00 00 00 00 00 45 00 00 ff ff ff ff ff ff ff Address 0x70: ff ff ff f3 55 55 55 55 55 55 55 55 55 55 55 55 Copyright © 2018, Juniper Networks, Inc.
  • Page 217 QSFP+-40G-SR4 Xcvr 1 REV 01 740-032986 QH0400VM QSFP+-40G-SR4 Xcvr 35 REV 01 740-058734 1ECQ11390ZB QSFP-100GBASE-SR4 FPC 8 REV 36 750-077140 ACNP4625 LC1102 - 12C / 36Q / 144X Jedec Code: 0x7fb0 EEPROM Version: 0x02 Copyright © 2018, Juniper Networks, Inc.
  • Page 218 0x7fb0 EEPROM Version: 0x02 P/N: 750-071976 S/N: ACPD3055 Assembly ID: 0x0be8 Assembly Version: 01.35 Date: 05-26-2016 Assembly Flags: 0x00 Version: REV 35 CLEI Code: CMUIANABAA ID: ULC-30Q28 FRU Model Number: JNP10K-LC1101 Board Information Record: Copyright © 2018, Juniper Networks, Inc.
  • Page 219 CLEI Code: CMUPADNBAA ID: QFX10000 AC FRU Model Number: QFX10000-PWR-AC Board Information Record: Address 0x00: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff I2C Hex Data: Copyright © 2018, Juniper Networks, Inc.
  • Page 220 Address 0x50: 46 58 31 30 30 30 30 2d 50 57 52 2d 41 43 00 00 Address 0x60: 00 00 00 00 00 00 01 30 31 ff ff ff ff ff ff ff Copyright © 2018, Juniper Networks, Inc.
  • Page 221 REV 10 750-050309 ACPM2918 Fan Controller 16 Jedec Code: 0x7fb0 EEPROM Version: 0x02 P/N: 750-050309 S/N: ACPM2918 Assembly ID: 0x0b9c Assembly Version: 01.10 Date: 01-13-2017 Assembly Flags: 0x00 Version: REV 10 CLEI Code: CMUCAH5CAA Copyright © 2018, Juniper Networks, Inc.
  • Page 222 Address 0x10: 00 00 00 00 37 36 30 2d 30 35 37 39 30 31 00 00 Address 0x20: 53 2f 4e 20 41 43 50 4c 30 35 34 36 00 0e 02 07 Copyright © 2018, Juniper Networks, Inc.
  • Page 223 Address 0x60: 00 00 00 00 00 00 41 42 00 ff ff ff ff ff ff ff Address 0x70: ff ff ff d3 00 00 00 00 00 00 00 00 00 00 00 00 SIB 3 REV 15 750-058270 ACPJ9834 Switch Fabric 16 Jedec Code: 0x7fb0 EEPROM Version: 0x02 Copyright © 2018, Juniper Networks, Inc.
  • Page 224 Assembly Version: 01.07 Date: 02-12-2017 Assembly Flags: 0x00 Version: REV 07 ID: QFX10000 FPD Board Information Record: Address 0x00: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff Copyright © 2018, Juniper Networks, Inc.
  • Page 225 Fan Tray 1 REV 09 760-054372 ACNZ3584 QFX10008-FAN SIB 0 REV 24 750-050058 ACPD4587 QFX10008-SF SIB 1 REV 24 750-050058 ACNZ0635 QFX10008-SF SIB 2 REV 24 750-050058 ACPD4908 QFX10008-SF SIB 3 REV 24 750-050058 ACNZ0617 QFX10008-SF Copyright © 2018, Juniper Networks, Inc.
  • Page 226 ACPS8855 show chassis hardware clei-models (MX104 Router) user@host> show chassis hardware clei-models Hardware inventory: Item Version Part number CLEI code FRU model number Midplane REV 20 750-044219 PROTOXCLEI PROTO-ASSEMBLY PEM 0 REV 01 740-045932 Copyright © 2018, Juniper Networks, Inc.
  • Page 227 Xcvr 3 REV 01 740-011613 PBG43VQ SFP-SX Fan Tray 0 REV 01 710-021113 JS4642 MX240 Fan Tray show chassis hardware detail (MX 240 Router with Routing Engine Displaying DIMM Information) user@host> show chassis hardware detail Copyright © 2018, Juniper Networks, Inc.
  • Page 228 Xcvr 0 REV 01 740-011613 PBG3YG7 SFP-SX Xcvr 1 REV 01 740-011613 PBG3XZ9 SFP-SX Xcvr 2 REV 01 740-011613 PBG3XTY SFP-SX Xcvr 3 REV 01 740-011613 PBG3UZG SFP-SX PIC 3 BUILTIN BUILTIN 10x 1GE(LAN) EQ Copyright © 2018, Juniper Networks, Inc.
  • Page 229 DPC PMB PIC 0 BUILTIN BUILTIN 10x 1GE(LAN) EQ PIC 1 BUILTIN BUILTIN 10x 1GE(LAN) EQ PIC 2 BUILTIN BUILTIN 10x 1GE(LAN) EQ PIC 3 BUILTIN BUILTIN 10x 1GE(LAN) EQ Fan Tray Left Fan Tray Copyright © 2018, Juniper Networks, Inc.
  • Page 230 CFP2-100G-LR4-D PIC 2 BUILTIN BUILTIN 2X10GE SFPP OTN Xcvr 0 REV 01 740-031980 AJC0BM3 SFP+-10G-SR Xcvr 1 REV 01 740-021308 11T511100917 SFP+-10G-SR PIC 3 BUILTIN BUILTIN 1X100GE CFP2 OTN Xcvr 0 NON-JNPR UQK07SU CFP2-100G-LR4-D Copyright © 2018, Juniper Networks, Inc.
  • Page 231 REV 10 711-029089 ABBP5410 AMPC PMB PIC 0 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-021308 983152A00038 SFP+-10G-SR Xcvr 1 REV 01 740-031980 B11F00211 SFP+-10G-SR Xcvr 2 REV 01 740-031980 AQ72LPB SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 232 MIC 0 REV 19 750-033199 CAAJ9719 1X100GE CFP PIC 0 BUILTIN BUILTIN 1X100GE CFP Xcvr 0 REV 01 740-035329 UP1020P CFP-100G-SR10 MIC 1 REV 07 750-033196 YZ0797 1X100GE CXP PIC 2 BUILTIN BUILTIN 1X100GE CXP Copyright © 2018, Juniper Networks, Inc.
  • Page 233 Address 0x50: 52 41 46 54 2d 4d 58 34 38 30 2d 53 00 00 00 00 Address 0x60: 00 00 00 00 00 00 ff ff ff ff ff ff ff ff ff ff Copyright © 2018, Juniper Networks, Inc.
  • Page 234 Address 0x70: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Routing Engine 0 REV 05 740-031116 9009092471 RE-S-1800x4 Jedec Code: 0x7fb0 EEPROM Version: 0x02 P/N: 740-031116 S/N: 9009092471 Copyright © 2018, Juniper Networks, Inc.
  • Page 235 PS 1.7kW; 200-240VAC in Routing Engine 0 REV 00 740-015113 1000617944 RE-S-1300 CB 0 REV 05 710-013725 JK6947 MX960 Test SCB FPC 4 REV 01 710-013305 JM7617 MX960 Test DPC PIC 0 BUILTIN BUILTIN 1x 10GE(LAN/WAN) Copyright © 2018, Juniper Networks, Inc.
  • Page 236 PIC 3 BUILTIN BUILTIN 10x 1GE(LAN) Xcvr 0 REV 01 740-017726 74S184H30341 SFP-EX Xcvr 1 REV 01 740-017726 4814061 SFP-EX Xcvr 5 REV 01 740-017726 6ZS184H31108 SFP-EX Xcvr 9 REV 01 740-021340 76E245X00486 SFP-1000BASE-BX10-U Copyright © 2018, Juniper Networks, Inc.
  • Page 237 FPC 2 REV 08 710-014219 JY9654 DPCE 4x 10GE R REV 06 710-013713 JZ6549 DPC PMB PIC 0 BUILTIN BUILTIN 1x 10GE(LAN/WAN) PIC 1 BUILTIN BUILTIN 1x 10GE(LAN/WAN) PIC 2 BUILTIN BUILTIN 1x 10GE(LAN/WAN) Copyright © 2018, Juniper Networks, Inc.
  • Page 238 Hardware inventory: Item Version Part number Serial number FRU model number Midplane REV 03 710-013698 TR0183 CHAS-BP-MX960-S Fan Extender REV 02 710-018051 JY5227 ECM-MX960 FPM Board REV 03 710-014974 JZ6876 CRAFT-MX960-S Copyright © 2018, Juniper Networks, Inc.
  • Page 239 REV 08 711-035209 CABE7370 HMPC PMB 2G MIC 0 REV 07 750-033307 CABD5255 10X10GE SFPP PIC 0 BUILTIN BUILTIN 10X10GE SFPP Xcvr 0 REV 01 740-021308 AQ50319 SFP+-10G-SR Xcvr 1 REV 01 740-021308 AQ5035V SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 240 FPC 7 REV 09 750-037355 CAAF0937 MPC4E 3D 2CGE+8XGE REV 08 711-035209 CAAD8004 HMPC PMB 2G PIC 0 BUILTIN BUILTIN 4x10GE SFPP Xcvr 0 REV 01 740-021308 ANA0MM3 SFP+-10G-SR PIC 1 BUILTIN BUILTIN 1X100GE CFP Copyright © 2018, Juniper Networks, Inc.
  • Page 241 Xcvr 10 REV 01 740-021308 AQA07AP SFP+-10G-SR Xcvr 11 REV 01 740-021308 AQA08YB SFP+-10G-SR PIC 2 BUILTIN BUILTIN 3X40GE QSFPP PIC 3 BUILTIN BUILTIN 3X40GE QSFPP WAN MEZZ REV 07 750-045717 CAAX3123 MPC5E 24XGE Mezz Copyright © 2018, Juniper Networks, Inc.
  • Page 242 MX960 Midplane REV 01 710-030012 ACAX3674 MX960 Backplane FPM Board REV 03 710-014974 CAAZ9326 Front Panel Display Rev 03 740-013110 QCS17025017 Power Distribution Module PEM 0 Rev 10 740-027760 QCS1702N062 PS 4.1kW; 200-240V AC Copyright © 2018, Juniper Networks, Inc.
  • Page 243 Xcvr 1 REV 01 740-021308 AQ501RZ SFP+-10G-SR Xcvr 2 REV 01 740-021308 AQ5029V SFP+-10G-SR Xcvr 3 REV 01 740-021308 AQ501X9 SFP+-10G-SR PIC 2 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-021308 AQ502ZN SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 244 REV 09 750-049136 CABN0415 MPC5E 24XGE OTN Mezz FPC 9 REV 05 750-044444 CAAY9801 MPCE Type 2 3D P REV 04 711-038484 CAAW3673 MPCE PMB 2G MIC 0 REV 28 750-028387 CAAX1071 3D 4x 10GE Copyright © 2018, Juniper Networks, Inc.
  • Page 245 Enhanced Fan Tray Fan Tray 1 REV 08 740-031521 ACAF4225 Enhanced Fan Tray show chassis hardware extensive (MX960 Router with MPC5EQ) user@host> show chassis hardware extensive Hardware inventory: Item Version Part number Serial number Description Copyright © 2018, Juniper Networks, Inc.
  • Page 246 Power Distribution Module Jedec Code: 0x7fb0 EEPROM Version: 0x01 P/N: 740-013110 S/N: QCS17025017 Assembly ID: 0x0416 Assembly Version: 01.03 Date: 01-10-2013 Assembly Flags: 0x00 Version: Rev 03 ID: Power Distribution Module Board Information Record: Copyright © 2018, Juniper Networks, Inc.
  • Page 247 Address 0x00: 7f b0 01 ff 04 30 01 09 52 65 76 20 30 39 00 00 Address 0x10: 00 00 00 00 37 34 30 2d 30 32 37 37 36 30 00 00 Copyright © 2018, Juniper Networks, Inc.
  • Page 248 REV 18 CLEI Code: COUCASRBAA ID: Enhanced MX SCB FRU Model Number: SCBE-MX-S Board Information Record: Address 0x00: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff Copyright © 2018, Juniper Networks, Inc.
  • Page 249 Address 0x40: ff ff ff ff 01 50 52 4f 54 4f 58 43 4c 45 49 50 Address 0x50: 52 4f 54 4f 2d 41 53 53 45 4d 42 4c 59 00 00 00 Copyright © 2018, Juniper Networks, Inc.
  • Page 250 Address 0x70: 00 00 00 00 c0 03 f3 8c 31 5c e7 80 00 00 00 02 Xcvr 0 REV 01 740-046563 XD16FC03Z CFP2-100G-SR10 PIC 2 BUILTIN BUILTIN 2X10GE SFPP OTN Jedec Code: 0x0000 EEPROM Version: 0x00 P/N: BUILTIN S/N: BUILTIN Assembly ID: 0x0a90 Assembly Version: 00.00 Copyright © 2018, Juniper Networks, Inc.
  • Page 251 Assembly Flags: 0x00 Version: REV 08 ID: HMPC PMB 2G Board Information Record: Address 0x00: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff I2C Hex Data: Copyright © 2018, Juniper Networks, Inc.
  • Page 252 740-046563 XD16FC064 CFP2-100G-SR10 FPC 3 REV 35 750-028467 CAAT9156 MPC 3D 16x 10GE Jedec Code: 0x7fb0 EEPROM Version: 0x01 P/N: 750-028467 S/N: CAAT9156 Assembly ID: 0x0997 Assembly Version: 01.35 Date: 12-17-2012 Assembly Flags: 0x00 Copyright © 2018, Juniper Networks, Inc.
  • Page 253 00.00 Date: 00-00-0000 Assembly Flags: 0x00 ID: 4x 10GE(LAN) SFP+ Board Information Record: Address 0x00: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 I2C Hex Data: Copyright © 2018, Juniper Networks, Inc.
  • Page 254 CLEI code FRU model number Midplane REV 01 710-030012 COM8T00CRB CHAS-BP-MX960-S FPM Board REV 03 710-014974 CRAFT-MX960-S PEM 0 Rev 10 740-027760 PWR-MX960-4100-AC-S PEM 1 Rev 04 740-027760 PWR-MX960-4100-AC-S PEM 2 Rev 09 740-027760 PWR-MX960-4100-AC-S Copyright © 2018, Juniper Networks, Inc.
  • Page 255 MPCE Type 3 3D REV 10 711-035209 CADJ1561 HMPC PMB 2G MIC 0 REV 05 750-057666 CAEB5763 1X100GE DWDM CFP2-ACO PIC 0 BUILTIN BUILTIN 1X100GE DWDM CFP2-ACO Xcvr 0 REV 01 740-062357 1DJBZ052002 OTN-100G-LH Copyright © 2018, Juniper Networks, Inc.
  • Page 256 REV 03 750-054097 ACAM1747 JNP10008 Midplane Routing Engine 0 BUILTIN BUILTIN RE-S-2X00x10 Routing Engine 1 BUILTIN BUILTIN RE-S-2X00x10 CB 0 REV 17 750-052688 ACAM7468 Control Board CB 1 REV 18 750-052688 ACAM7709 Control Board Copyright © 2018, Juniper Networks, Inc.
  • Page 257 BUILTIN BUILTIN SMPC PMB PIC 0 REV 17 750-059747 ACNW3510 5X100GE DWDM CFP2-ACO Xcvr 0 REV 01 740-062357 1DJBZ040003 OTN-100G-LH Xcvr 2 REV 01 740-062357 1DJBZ044004 OTN-100G-LH Xcvr 3 REV 01 740-062357 1DJBZ03500P OTN-100G-LH Copyright © 2018, Juniper Networks, Inc.
  • Page 258 REV 01 711-057066 PROTOXCLEI PROTO-ASSEMBLY SIB 7 REV 01 750-057067 PROTOXCLEI PROTO-ASSEMBLY SIB 8 REV 01 750-057067 PROTOXCLEI PROTO-ASSEMBLY Fan Tray 0 REV 13 760-044659 IPUCBE8CAA FAN-SFF-PTX-S Fan Tray 1 REV 13 760-044659 IPUCBE8CAA FAN-SFF-PTX-S Copyright © 2018, Juniper Networks, Inc.
  • Page 259 740-021308 AMH02HT SFP+-10G-SR Xcvr 3 REV 01 740-021308 AMH04V4 SFP+-10G-SR FPC 1 REV 21 750-033205 ZG5027 MPC Type 3 REV 04 711-035209 YT4780 HMPC PMB 2G MIC 0 REV 03 750-033307 ZV6299 10X10GE SFPP Copyright © 2018, Juniper Networks, Inc.
  • Page 260 PIC 1 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-031980 1YT517101828 SFP+-10G-SR Xcvr 1 REV 01 740-031980 1YT517101716 SFP+-10G-SR Xcvr 2 REV 01 740-031980 1YT517101732 SFP+-10G-SR Xcvr 3 REV 01 740-031980 ALP0TR1 SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 261 SGU04G72H1BD2SA-BB DIE REV-52 PCB REV-54 MFR ID-ce80 Routing Engine 1 REV 02 740-041821 9009099706 RE-S-1800x4 3998 MB Virtium - TuffDrive VCF P1T0200262860208 114 Compact Flash 30533 MB UGB94ARF32H0S3-KC UNIGEN-499551-000404 Disk 1 CB 0 REV 13 750-040257 CAAF8436 Control Board Copyright © 2018, Juniper Networks, Inc.
  • Page 262 Xcvr 0 REV 01 740-031980 AMA062M SFP+-10G-SR Xcvr 1 REV 01 740-021308 973152A00080 SFP+-10G-SR Xcvr 2 REV 01 740-031980 193363A00580 SFP+-10G-SR Xcvr 3 REV 01 740-021308 973152A00064 SFP+-10G-SR Xcvr 4 REV 01 740-031980 093363A01494 SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 263 Xcvr 0 REV 01 740-031980 AMA04CC SFP+-10G-SR Xcvr 1 REV 01 740-021308 AD0927A001W SFP+-10G-SR Xcvr 2 REV 01 740-031980 AMA04N2 SFP+-10G-SR Xcvr 3 REV 01 740-031980 AMA062U SFP+-10G-SR Xcvr 4 REV 01 740-031980 193363A00491 SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 264 Xcvr 1 REV 01 740-031980 B11G00586 SFP+-10G-SR Xcvr 2 REV 01 740-031980 AMA08B7 SFP+-10G-SR Xcvr 3 REV 01 740-031980 AMA04Q0 SFP+-10G-SR Xcvr 4 REV 01 740-031980 B11D05840 SFP+-10G-SR Xcvr 5 REV 01 740-031980 B11E00467 SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 265 Fan Tray 1 REV 2A 760-046960 ACAY0068 172mm FanTray - 6 Fans Fan Tray 2 REV 2A 760-046960 ACAY0072 172mm FanTray - 6 Fans Fan Tray 3 REV 2A 760-046960 ACAY0070 172mm FanTray - 6 Fans Copyright © 2018, Juniper Networks, Inc.
  • Page 266 Address 0x70: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff REV 04 711-032426 ACAJ1677 Power Midplane Jedec Code: 0x7fb0 EEPROM Version: 0x01 P/N: 711-032426 S/N: ACAJ1677 Copyright © 2018, Juniper Networks, Inc.
  • Page 267 P/N: 740-045050 S/N: 1E02224000M Assembly ID: 0x0478 Assembly Version: 01.01 Date: 12-06-2012 Assembly Flags: 0x00 Version: REV 01 CLEI Code: XXXXXXXXXX ID: DC 52V Power Supply Module FRU Model Number: MX2000-PSM-HC-DC-S-A Board Information Record: Copyright © 2018, Juniper Networks, Inc.
  • Page 268 SGU04G72H1BD2SA-BB DIE REV-52 PCB REV-54 MFR ID-ce80 Routing Engine 1 REV 02 740-041821 9009099706 RE-S-1800x4 Jedec Code: 0x7fb0 EEPROM Version: 0x02 P/N: 740-041821 S/N: 9009099706 Assembly ID: 0x09c0 Assembly Version: 01.02 Date: 02-23-2012 Assembly Flags: 0x00 Version: REV 02 Copyright © 2018, Juniper Networks, Inc.
  • Page 269 REV 05 CLEI Code: PROTOXCLEI ID: Switch Fabric Board FRU Model Number: PROTO-ASSEMBLY Board Information Record: Address 0x00: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff Copyright © 2018, Juniper Networks, Inc.
  • Page 270 Address 0x40: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Address 0x50: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Copyright © 2018, Juniper Networks, Inc.
  • Page 271 FPC 8 REV 22 750-031089 ZT9746 MX-MPC2-3D MIC 0 REV 26 750-028392 ABBS1150 MIC-3D-20GE-SFP MIC 1 REV 26 750-028387 ABBR9582 MIC-3D-4XGE-XFP FPC 9 REV 11 750-036284 ZL3591 MPCE-3D-16XGE-SFPP ADC 0 REV 05 750-043596 CAAC2073 750-043596 Copyright © 2018, Juniper Networks, Inc.
  • Page 272 Description Chassis JN11C9AFEAFK MX2010 Midplane REV 35 750-044636 ABAB9188 Lower Backplane Midplane 1 REV 02 711-044557 ABAB8729 Upper Backplane REV 04 711-032426 ACAJ2432 Power Midplane FPM Board REV 09 760-044634 ABCA4314 Front Panel Display Copyright © 2018, Juniper Networks, Inc.
  • Page 273 711-046638 ABCT7809 MPC6E XL FPC 6 REV 30 750-028467 ZM4986 MPC 3D 16x 10GE REV 10 711-029089 ZP6541 AMPC PMB PIC 0 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-021308 AQ43GAC SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 274 DC 52V Power Supply Module PSM 4 REV 01 740-050037 1EDB321015G DC 52V Power Supply Module PSM 5 REV 01 740-050037 1EDB32101HH DC 52V Power Supply Module PSM 6 REV 01 740-050037 1EDB32101HD DC 52V Power Supply Copyright © 2018, Juniper Networks, Inc.
  • Page 275 PIC 0 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-021308 AQ43GAC SFP+-10G-SR PIC 1 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-031980 ALM0A6D SFP+-10G-SR Xcvr 1 REV 01 740-031980 AQF0RB3 SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 276 Address 0x70: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Midplane REV 35 750-044636 ABAB9188 Lower Backplane Jedec Code: 0x7fb0 EEPROM Version: 0x02 P/N: 750-044636 S/N: ABAB9188 Assembly ID: 0x0b66 Assembly Version: 01.35 Copyright © 2018, Juniper Networks, Inc.
  • Page 277 Address 0x00: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff I2C Hex Data: Address 0x00: 7f b0 02 ff 0b 64 01 09 52 45 56 20 30 39 00 00 Copyright © 2018, Juniper Networks, Inc.
  • Page 278 Address 0x30: dd ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff Address 0x40: ff ff ff ff 01 49 50 55 50 41 4b 52 4b 41 41 4d Copyright © 2018, Juniper Networks, Inc.
  • Page 279 Address 0x60: 00 00 00 00 00 00 31 30 31 ff ff ff ff ff ff ff Address 0x70: ff ff ff 2a 00 00 00 00 00 00 00 00 00 00 00 00 PSM 6 REV 01 740-050037 1EDB32101HD DC 52V Power Supply Copyright © 2018, Juniper Networks, Inc.
  • Page 280 Address 0x70: ff ff ff 2a 00 00 00 00 00 00 00 00 00 00 00 00 PDM 0 REV 03 740-045234 1EFA3220433 DC Power Dist Module Jedec Code: 0x7fb0 EEPROM Version: 0x02 P/N: 740-045234 S/N: 1EFA3220433 Assembly ID: 0x047b Assembly Version: 01.03 Date: 05-30-2013 Assembly Flags: 0x00 Copyright © 2018, Juniper Networks, Inc.
  • Page 281 Module PSM 12 REV 01 740-045050 1E022240051 DC 52V Power Supply Module PSM 13 REV 01 740-045050 1E022240058 DC 52V Power Supply Module PSM 14 REV 01 740-045050 1E02224004L DC 52V Power Supply Module Copyright © 2018, Juniper Networks, Inc.
  • Page 282 Xcvr 2 REV 01 740-030658 B11F01675 SFP+-10G-USR Xcvr 3 REV 01 740-030658 B11F01901 SFP+-10G-USR PIC 2 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-030658 B11F01346 SFP+-10G-USR Xcvr 1 REV 01 740-030658 B11F01288 SFP+-10G-USR Copyright © 2018, Juniper Networks, Inc.
  • Page 283 Xcvr 2 REV 01 740-030658 B11E01195 SFP+-10G-USR Xcvr 3 REV 01 740-030658 B11F01743 SFP+-10G-USR PIC 1 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-030658 B11F01892 SFP+-10G-USR Xcvr 1 REV 01 740-030658 B11E02880 SFP+-10G-USR Copyright © 2018, Juniper Networks, Inc.
  • Page 284 REV 32 750-028467 ABBN6811 MPC 3D 16x 10GE REV 10 711-029089 ABBN7288 AMPC PMB PIC 0 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-031980 AK80NK8 SFP+-10G-SR Xcvr 1 REV 01 740-031980 AK80LJG SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 285 PIC 3 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-031980 AK80FKQ SFP+-10G-SR Xcvr 1 REV 01 740-031980 AK80NLT SFP+-10G-SR Xcvr 2 REV 01 740-031980 AK80NKR SFP+-10G-SR Xcvr 3 REV 01 740-031980 AK80LKM SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 286 PIC 2 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-031980 163363A02725 SFP+-10G-SR Xcvr 1 REV 01 740-031980 163363A02692 SFP+-10G-SR Xcvr 2 REV 01 740-031980 163363A02730 SFP+-10G-SR Xcvr 3 REV 01 740-031980 163363A03081 SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 287 PIC 1 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-031980 B11K00427 SFP+-10G-SR Xcvr 1 REV 01 740-031980 B11K00430 SFP+-10G-SR Xcvr 2 REV 01 740-031980 B11K01854 SFP+-10G-SR Xcvr 3 REV 01 740-031980 B11K00426 SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 288 PIC 0 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-031980 163363A02569 SFP+-10G-SR Xcvr 1 REV 01 740-031980 163363A02886 SFP+-10G-SR Xcvr 2 REV 01 740-031980 163363A03082 SFP+-10G-SR Xcvr 3 REV 01 740-031980 133363A00297 SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 289 Fan Tray 1 REV 2A 760-046960 ACAY0039 172mm FanTray - 6 Fans Fan Tray 2 REV 2A 760-046960 ACAY0033 172mm FanTray - 6 Fans Fan Tray 3 REV 2A 760-046960 ACAY0062 172mm FanTray - 6 Fans Copyright © 2018, Juniper Networks, Inc.
  • Page 290 UNIGEN-478612-001044 Disk 1 CB 0 REV 08 750-040257 CAAB3482 Control Board CB 1 REV 04 750-040257 ZT2864 Control Board SPMB 0 REV 02 711-041855 CAAA6141 PMB Board SPMB 1 REV 01 711-041855 ZS2275 PMB Board Copyright © 2018, Juniper Networks, Inc.
  • Page 291 Xcvr 1 REV 01 740-031980 B11K01848 SFP+-10G-SR Xcvr 2 REV 01 740-031980 B11K01865 SFP+-10G-SR Xcvr 3 REV 01 740-031980 B11K00540 SFP+-10G-SR PIC 1 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-031980 B11K00422 SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 292 REV 01 740-031980 AK80NLE SFP+-10G-SR FPC 5 REV 32 750-028467 ABBN6791 MPC 3D 16x 10GE REV 10 711-029089 ABBN7289 AMPC PMB PIC 0 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-031980 B11K00424 SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 293 Xcvr 3 REV 01 740-031980 163363A02660 SFP+-10G-SR PIC 3 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-031980 163363A02731 SFP+-10G-SR Xcvr 1 REV 01 740-031980 163363A02588 SFP+-10G-SR Xcvr 2 REV 01 740-031980 163363A02673 SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 294 Xcvr 3 REV 01 740-030658 B11E02819 SFP+-10G-USR PIC 2 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-030658 B11E02812 SFP+-10G-USR Xcvr 1 REV 01 740-030658 B11D04437 SFP+-10G-USR Xcvr 2 REV 01 740-030658 B11F01279 SFP+-10G-USR Copyright © 2018, Juniper Networks, Inc.
  • Page 295 Xcvr 3 REV 01 740-030658 B11F01439 SFP+-10G-USR PIC 1 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-030658 B11E04739 SFP+-10G-USR Xcvr 1 REV 01 740-030658 B11F01869 SFP+-10G-USR Xcvr 2 REV 01 740-030658 B11F01675 SFP+-10G-USR Copyright © 2018, Juniper Networks, Inc.
  • Page 296 REV 10 711-029089 ABBJ0966 AMPC PMB PIC 0 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Xcvr 0 REV 01 740-031980 AK80NL1 SFP+-10G-SR Xcvr 1 REV 01 740-031980 AK80NXW SFP+-10G-SR Xcvr 2 REV 01 740-031980 AK80KD2 SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 297 740-030658 B11E04359 SFP+-10G-USR Xcvr 1 REV 01 740-030658 B11E02751 SFP+-10G-USR Xcvr 2 REV 01 740-030658 B11E02736 SFP+-10G-USR Xcvr 3 REV 01 740-030658 B11E01178 SFP+-10G-USR FPC 19 REV 32 750-028467 ABBN6813 MPC 3D 16x 10GE Copyright © 2018, Juniper Networks, Inc.
  • Page 298 PSM 3 REV 01 740-045050 1E022240056 MX2000-PSM-HC-DC-S-A PSM 4 REV 01 740-045050 1E022240054 MX2000-PSM-HC-DC-S-A PSM 5 REV 01 740-045050 1E02224005H MX2000-PSM-HC-DC-S-A PSM 6 REV 01 740-045050 1E02224006S MX2000-PSM-HC-DC-S-A PSM 7 REV 01 740-045050 1E02224005M MX2000-PSM-HC-DC-S-A Copyright © 2018, Juniper Networks, Inc.
  • Page 299 ADC 17 REV 13 750-043596 ABBX5559 PROTO-ASSEMBLY ADC 18 REV 13 750-043596 ABBX5537 PROTO-ASSEMBLY ADC 19 REV 11 750-043596 ABBW5685 PROTO-ASSEMBLY Fan Tray 0 REV 04 760-046960 ACAY0090 Fan Tray 1 REV 04 760-046960 ACAY0088 Copyright © 2018, Juniper Networks, Inc.
  • Page 300 MPC-3D-16XGE-SFPP FPC 18 REV 30 750-028467 MPC-3D-16XGE-SFPP FPC 19 REV 32 750-028467 MPC-3D-16XGE-SFPP ADC 0 REV 13 750-043596 PROTOXCLEI PROTO-ASSEMBLY ADC 1 REV 13 750-043596 PROTOXCLEI PROTO-ASSEMBLY ADC 2 REV 13 750-043596 IPUCBA8CAA MX2000-LC-ADAPTER Copyright © 2018, Juniper Networks, Inc.
  • Page 301 DC 52V Power Supply Module PSM 15 REV 01 740-050037 1EDB3130024 DC 52V Power Supply Module PSM 16 REV 01 740-050037 1EDB3130054 DC 52V Power Supply Module PSM 17 REV 01 740-050037 1EDB3130080 DC 52V Power Supply Copyright © 2018, Juniper Networks, Inc.
  • Page 302 Xcvr 3 REV 01 740-021308 AQ43H8D SFP+-10G-SR Xcvr 4 REV 01 740-021308 19T511100370 SFP+-10G-SR Xcvr 5 REV 01 740-031980 153363A00763 SFP+-10G-SR Xcvr 6 REV 01 740-021308 APH2LXB SFP+-10G-SR Xcvr 7 REV 01 740-031980 AMC0LVV SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 303 REV 01 740-031980 AJ30CU7 SFP+-10G-SR FPC 9 REV 30 750-044130 ABCF5773 MPC6E 3D REV 09 711-045719 ABCF1270 RMPC PMB MIC 0 REV 05 750-049457 ABCD7829 2X100GE CFP2 OTN PIC 0 BUILTIN BUILTIN 2X100GE CFP2 OTN Copyright © 2018, Juniper Networks, Inc.
  • Page 304 Xcvr 13 REV 01 740-031980 AMC0JTC SFP+-10G-SR Xcvr 14 REV 01 740-021308 ANA0MQ0 SFP+-10G-SR Xcvr 15 REV 01 740-021308 AQ502GS SFP+-10G-SR Xcvr 16 REV 01 740-021308 AQG0M0J SFP+-10G-SR Xcvr 17 REV 01 740-021308 AQG0MUR SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 305 Fan Tray 1 REV 06 760-046960 ACAY0788 172mm FanTray - 6 Fans Fan Tray 2 REV 06 760-046960 ACAY0755 172mm FanTray - 6 Fans Fan Tray 3 REV 06 760-046960 ACAY0441 172mm FanTray - 6 Fans Copyright © 2018, Juniper Networks, Inc.
  • Page 306 3998 MB Virtium - TuffDrive VCF P1T0200274310822 366 Compact Flash 30533 MB UGB94BPH32H0S1-KCI 11000039979 Disk 1 CB 0 REV 23 750-040257 CABA2295 Control Board CB 1 REV 23 750-040257 CABE8379 Control Board SPMB 0 Copyright © 2018, Juniper Networks, Inc.
  • Page 307 Address 0x00: ad 01 10 00 4c 96 14 72 30 08 ff ff ff ff ff ff I2C Hex Data: Address 0x00: 7f b0 02 ff 0b 22 01 33 52 45 56 20 35 31 00 00 Copyright © 2018, Juniper Networks, Inc.
  • Page 308 Address 0x60: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff Address 0x70: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff Copyright © 2018, Juniper Networks, Inc.
  • Page 309 Address 0x70: ff ff ff 2a 00 00 00 00 00 00 00 00 00 00 00 00 PSM 2 REV 01 740-050037 1EDB32403KM DC 52V Power Supply Module Jedec Code: 0x7fb0 EEPROM Version: 0x02 P/N: 740-050037 S/N: 1EDB32403KM Assembly ID: 0x0478 Assembly Version: 01.01 Copyright © 2018, Juniper Networks, Inc.
  • Page 310 P/N: 740-050037 S/N: 1EDB3130020 Assembly ID: 0x0478 Assembly Version: 01.01 Date: 05-16-2013 Assembly Flags: 0x00 Version: REV 01 CLEI Code: IPUPAKRKAA ID: DC 52V Power Supply Module FRU Model Number: MX2000-PSM-DC-S Board Information Record: Copyright © 2018, Juniper Networks, Inc.
  • Page 311 Address 0x00: 7f b0 02 ff 04 78 01 01 52 45 56 20 30 31 00 00 Address 0x10: 00 00 00 00 37 34 30 2d 30 35 30 30 33 37 00 00 Copyright © 2018, Juniper Networks, Inc.
  • Page 312 Address 0x40: ff ff ff ff 01 49 50 55 50 41 4b 52 4b 41 41 4d Address 0x50: 58 32 30 30 30 2d 50 53 4d 2d 44 43 2d 53 00 00 Copyright © 2018, Juniper Networks, Inc.
  • Page 313 FPC 2 REV 17 750-037355 CAAS5826 MPC4E-3D-2CGE-8XGE FPC 3 REV 05 750-044444 CAAY9920 MX-MPC2E-3D-P FPC 4 REV 18 750-046005 CACH5661 PROTO-ASSEMBLY FPC 5 REV 35 750-028467 CAAR2623 MPC-3D-16XGE-SFPP FPC 9 REV 30 750-044130 ABCF5773 PROTO-ASSEMBLY Copyright © 2018, Juniper Networks, Inc.
  • Page 314 FPC 3 REV 05 750-044444 COUIBBGBAA MX-MPC2E-3D-P MIC 0 REV 28 750-028387 COUIA16BAA MIC-3D-4XGE-XFP FPC 4 REV 18 750-046005 PROTOXCLEI PROTO-ASSEMBLY FPC 5 REV 35 750-028467 MPC-3D-16XGE-SFPP FPC 9 REV 30 750-044130 PROTOXCLEI PROTO-ASSEMBLY Copyright © 2018, Juniper Networks, Inc.
  • Page 315 24145-00175 Load SFP Xcvr 7 NON-JNPR 23393-00627 UNKNOWN QXM 0 REV 05 711-028408 YF4681 MPC QXM QXM 1 REV 05 711-028408 YF4817 MPC QXM Fan Tray 0 REV 01 710-021113 XL3645 MX240 Fan Tray Copyright © 2018, Juniper Networks, Inc.
  • Page 316 Address 0x00: 7f b0 02 ff 0b 38 01 04 52 45 56 20 30 34 00 00 Address 0x10: 00 00 00 00 37 31 31 2d 30 33 38 31 37 33 00 00 Copyright © 2018, Juniper Networks, Inc.
  • Page 317 Xcvr 1 REV 01 740-031980 B11D05809 SFP+-10G-SR PIC 1 BUILTIN BUILTIN 1X100GE CFP Xcvr 0 NON-JNPR D5418 UNKNOWN PIC 2 BUILTIN BUILTIN 4x10GE SFPP PIC 3 BUILTIN BUILTIN 1X100GE CFP Xcvr 0 NON-JNPR X12J00362 CFP-100G-SR10 Copyright © 2018, Juniper Networks, Inc.
  • Page 318 750-033535 CAAD7674 MIC-3D-1OC192-XFP PIC 0 BUILTIN BUILTIN MIC-3D-1OC192-XFP Xcvr 0 REV 01 740-014279 753019A00404 XFP-OC192-SR MIC 1 REV 14 750-031967 ZM6103 MIC-3D-8OC3OC12-4OC48 PIC 2 BUILTIN BUILTIN MIC-3D-8OC3OC12-4OC48 Xcvr 0 REV 01 740-011615 PEF1AZP SFP-IR Copyright © 2018, Juniper Networks, Inc.
  • Page 319 Fan Tray 1 REV 2A 760-046960 ACAY0022 172mm FanTray - 6 Fans Fan Tray 2 REV 2A 760-046960 ACAY0023 172mm FanTray - 6 Fans Fan Tray 3 REV 2A 760-046960 ACAY0025 172mm FanTray - 6 Fans Copyright © 2018, Juniper Networks, Inc.
  • Page 320 PWR-MX80-AC-S Routing Engine BUILTIN BUILTIN TFEB 0 BUILTIN BUILTIN FPC 0 BUILTIN BUILTIN FPC 1 BUILTIN BUILTIN MIC 0 REV 02 750-049846 CAAV2153 MIC-3D-20GE-SFP-E MIC 1 REV 26 750-028392 ZY0187 MIC-3D-20GE-SFP Fan Tray FANTRAY-MX80-S Copyright © 2018, Juniper Networks, Inc.
  • Page 321 Fan Tray 0 REV 01 760-052467 ACAY6190 172mm FanTray - 6 Fans Fan Tray 1 REV 01 760-052467 ACAY6414 172mm FanTray - 6 Fans show chassis hardware detail (MX2008 Router) user@host>show chassis hardware detail Copyright © 2018, Juniper Networks, Inc.
  • Page 322 MPC QXM ADC 7 REV 17 750-043596 ABCA0990 Adapter Card Fan Tray 0 REV 01 760-052467 ACAY6190 172mm FanTray - 6 Fans Fan Tray 1 REV 01 760-052467 ACAY6414 172mm FanTray - 6 Fans Copyright © 2018, Juniper Networks, Inc.
  • Page 323 Address 0x60: 00 00 00 00 00 00 ff ff ff ff ff ff ff ff ff ff Address 0x70: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff FPM Board REV 02 760-068193 ABDG7408 Front Panel Display Jedec Code: 0x7fb0 EEPROM Version: 0x02 Copyright © 2018, Juniper Networks, Inc.
  • Page 324 740-050037 1EDB61200NY DC 52V Power Supply Module Jedec Code: 0x7fb0 EEPROM Version: 0x02 P/N: 740-050037 S/N: 1EDB61200NY Assembly ID: 0x0478 Assembly Version: 01.06 Date: 03-16-2016 Assembly Flags: 0x00 Version: REV 06 CLEI Code: IPUPAPDKAA Copyright © 2018, Juniper Networks, Inc.
  • Page 325 ID: DC 52V Power Supply Module FRU Model Number: MX2000-PSM-DC-S Board Information Record: Address 0x00: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff I2C Hex Data: Copyright © 2018, Juniper Networks, Inc.
  • Page 326 Address 0x40: ff ff ff ff 01 49 50 55 50 41 4e 31 4b 41 41 4d Address 0x50: 58 32 4b 2d 50 44 4d 2d 4f 50 2d 44 43 2d 53 00 Copyright © 2018, Juniper Networks, Inc.
  • Page 327 Address 0x50: 52 4f 54 4f 2d 41 53 53 45 4d 42 4c 59 00 00 00 Address 0x60: 00 00 00 00 00 00 41 30 30 ff ff ff ff ff ff ff Copyright © 2018, Juniper Networks, Inc.
  • Page 328 REV 08 750-067371 ABDK7188 Switch Fabric Board Jedec Code: 0x7fb0 EEPROM Version: 0x02 P/N: 750-067371 S/N: ABDK7188 Assembly ID: 0x0c97 Assembly Version: 01.08 Date: 09-28-2016 Assembly Flags: 0x00 Version: REV 08 CLEI Code: PROTOXCLEI Copyright © 2018, Juniper Networks, Inc.
  • Page 329 Address 0x10: 00 00 00 00 37 35 30 2d 30 36 37 33 37 31 00 00 Address 0x20: 53 2f 4e 20 41 42 44 4b 37 31 34 36 00 1b 09 07 Copyright © 2018, Juniper Networks, Inc.
  • Page 330 Address 0x60: 00 00 00 00 00 00 41 30 30 ff ff ff ff ff ff ff Address 0x70: ff ff ff c2 ff ff ff ff ff ff ff ff ff ff ff ff REV 09 711-045719 ABCS8776 RMPC PMB Jedec Code: 0x7fb0 EEPROM Version: 0x02 Copyright © 2018, Juniper Networks, Inc.
  • Page 331 REV 07.2.00 711-046638 ABCK5482 MPC6E XL Jedec Code: 0x7fb0 EEPROM Version: 0x02 P/N: 711-046638 S/N: ABCK5482 Assembly ID: 0x0b88 Assembly Version: 01.07 Date: 10-21-2013 Assembly Flags: 0x00 Version: REV 07.2.00 ID: MPC6E XL Board Information Record: Copyright © 2018, Juniper Networks, Inc.
  • Page 332 Address 0x30: dc ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff Address 0x40: ff ff ff ff 01 43 4f 55 49 42 41 35 42 41 41 4d Copyright © 2018, Juniper Networks, Inc.
  • Page 333 Address 0x70: ff ff ff 7b c0 03 e5 7c 4f 8a 9e 10 00 00 00 02 PIC 2 BUILTIN BUILTIN MIC-3D-8DS3-E3 QXM 0 REV 06 711-028408 ZW8299 MPC QXM Jedec Code: 0x7fb0 EEPROM Version: 0x01 Copyright © 2018, Juniper Networks, Inc.
  • Page 334 CLEI Code: IPUCBENCAA ID: 172mm FanTray - 6 Fans FRU Model Number: MX2000-FANTRAY-S Board Information Record: Address 0x00: ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff ff Copyright © 2018, Juniper Networks, Inc.
  • Page 335 MIC 0 REV 21 750-050008 ABCT5920 MIC6-100G-CXP FPC 1 REV 22 750-063414 CAFJ3026 MX2K-MPC9E FPC 7 REV 08 750-038492 ZX4080 MX-MPC2E-3D-EQ MIC 0 REV 05 750-037128 ZR4031 MIC-3D-4CHOC3-1OC12-CE MIC 1 REV 23 750-032479 CADE8614 MIC-3D-8DS3-E3 Copyright © 2018, Juniper Networks, Inc.
  • Page 336 REV 07 750-067071 CAGX4363 Mezz REV 10 711-066896 CAHS7193 SPM Mezz Board FPC 0 REV 05 750-066879 CAGV0273 LC2103 BUILTIN BUILTIN SMPC PMB PIC 0 PIC 1 FPC 1 REV 05 750-066879 CAGV0278 LC2103 Copyright © 2018, Juniper Networks, Inc.
  • Page 337 (vMX running in performance mode) user@host> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis VM54599D128A Midplane Routing Engine 0 RE-VMX CB 0 VMX SCB CB 1 VMX SCB FPC 0 Virtual FPC Copyright © 2018, Juniper Networks, Inc.
  • Page 338 JB6042 FPC CPU REV 01 710-005802 BC1566 FPC Type 2 REV 09 710-001726 AY4922 FPC CPU PIC 0 REV 02 750-008155 BE2114 2x G/E QPP, 1000 BASE SFP 0 REV 01 740-007326 P4R0PMQ SFP-SX Copyright © 2018, Juniper Networks, Inc.
  • Page 339 Part number CLEI code FRU model number Midplane REV 04 710-002726 CHAS-BP-T640-S FPM Display REV 02 710-002897 CRAFT-T640-S REV 05 710-002895 CIP-L-T640-S PEM 0 Rev 01 740-002595 PWR-T-DC-S SCG 0 REV 04 710-003423 SCG-T-S Copyright © 2018, Juniper Networks, Inc.
  • Page 340 REV 02 710-002901 HE3245 FPM Display REV 02 710-002897 HA4873 REV 05 710-002895 HA4729 PEM 1 RevX02 740-002595 MD21815 Power Entry Module SCG 0 REV 04 710-003423 HF6023 SCG 1 REV 04 710-003423 HF6061 Copyright © 2018, Juniper Networks, Inc.
  • Page 341 750-032819 EG3637 FPC Type 5-3D REV 09 711-030686 EG0150 SNG PMB PIC 0 REV 08 750-035293 EF3657 1x100GE Xcvr 0 REV 01 740-032210 C22CQNJ CFP-100G-LR4 PIC 1 REV 10 750-034624 BBAN4098 12x10GE (LAN/WAN) SFPP Copyright © 2018, Juniper Networks, Inc.
  • Page 342 SIB 0 REV 02 711-036340 EF8802 SIB-HC-3D SIB 1 REV 07 711-036340 EG2286 SIB-HC-3D SIB 2 REV 07 711-036340 EG2252 SIB-HC-3D SIB 3 REV 02 711-036340 EF1358 SIB-HC-3D SIB 4 REV 02 711-036340 EF8806 SIB-HC-3D Copyright © 2018, Juniper Networks, Inc.
  • Page 343 REV 07 750-034624 EF6830 12x10GE (LAN/WAN) SFPP show chassis hardware clei-models (T4000 Router) user@host> show chassis hardware clei-models Hardware inventory: Item Version Part number CLEI code FRU model number Midplane REV 01 710-027486 IPMJ700DRD CHAS-BP-T1600-S Copyright © 2018, Juniper Networks, Inc.
  • Page 344 REV 07 750-034624 EF6800 12x10GE (LAN/WAN) SFPP Xcvr 0 REV 01 740-031980 AJJ01SA SFP+-10G-SR Xcvr 1 REV 01 740-031980 AJJ01QZ SFP+-10G-SR Xcvr 2 REV 01 740-031980 AJH0217 SFP+-10G-SR Xcvr 3 REV 01 740-031980 AJJ01TE SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 345 Xcvr 1 REV 01 740-031980 AJJ01N0 SFP+-10G-SR Xcvr 2 REV 01 740-031980 AJJ01SV SFP+-10G-SR Xcvr 3 REV 01 740-031980 AJJ032L SFP+-10G-SR Xcvr 4 REV 01 740-031980 B10M01593 SFP+-10G-SR Xcvr 5 REV 01 740-031980 AJD0FF1 SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 346 Chassis 65751 T640 Midplane REV 03 710-005608 RA1408 T640 Backplane FPM GBUS REV 09 710-002901 RA2784 T640 FPM Board FPM Display REV 05 710-002897 RA2825 FPM Display REV 06 710-002895 HT0684 T Series CIP Copyright © 2018, Juniper Networks, Inc.
  • Page 347 SIB 3 SIB 4 REV 01 710-005839 HW1177 SIB-S8-F16 B Board REV 01 710-005840 HW1202 SIB-S8-F16 (B) show chassis hardware (T1600 Router) user@host> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Copyright © 2018, Juniper Networks, Inc.
  • Page 348 P6Q0F3E SFP-SR MMB 0 REV 03 710-004047 HD5843 MMB-288mbit MMB 1 REV 03 710-004047 HE3208 MMB-288mbit PPB 0 REV 02 710-002845 HA4524 PPB Type 3 PPB 1 REV 02 710-002845 HA4766 PPB Type 3 Copyright © 2018, Juniper Networks, Inc.
  • Page 349 Xcvr 0 REV 01 740-011613 AM0812S8XBZ SFP-SX Xcvr 1 REV 01 740-011613 AM0812S8XAP SFP-SX Xcvr 2 REV 01 740-011613 AM0812S8XBY SFP-SX Xcvr 3 REV 01 740-011613 AM0812S8XBX SFP-SX Xcvr 4 REV 01 740-011613 P9F1652 SFP-SX Copyright © 2018, Juniper Networks, Inc.
  • Page 350 REV 05 710-023787 DW8472 F2S SIB Mezz SIB F2S 1/0 REV 04 710-022603 DW4871 F2S SIB B Board REV 05 710-023787 DW8497 F2S SIB Mezz SIB F2S 1/2 REV 05 710-022603 DW7868 F2S SIB Copyright © 2018, Juniper Networks, Inc.
  • Page 351 740-011782 P8Q27ZG SFP-SX Xcvr 1 NON-JNPR PDA1U0D SFP-SX Xcvr 2 REV 01 740-011613 P9F1ALW SFP-SX Xcvr 3 REV 01 740-011782 PBA403V SFP-SX Xcvr 4 NON-JNPR PDE09DP SFP-SX Xcvr 5 REV 01 740-011782 PCH2P4K SFP-SX Copyright © 2018, Juniper Networks, Inc.
  • Page 352 750-001901 HB4225 4x OC-12 SONET, SMIR PIC 1 REV 05 750-001900 AD3644 1x OC-48 SONET, SMSR PIC 2 REV 10 750-008155 HV0335 2x G/E IQ, 1000 BASE Xcvr 0 REV 01 740-011782 PCH2UKF SFP-SX Copyright © 2018, Juniper Networks, Inc.
  • Page 353 REV 04 710-025563 BBAA5401 ST-MMB2 FPC 3 REV 10 710-021534 DZ0941 FPC Type 1-ES REV 09 710-016744 DY6364 ST-PMB2 PIC 0 REV 13 750-012266 DK9192 4x 1GE(LAN), IQ2 Xcvr 0 REV 01 740-011613 AM0812S8WVD SFP-SX Copyright © 2018, Juniper Networks, Inc.
  • Page 354 REV 07 710-022594 DW4200 LCC SIB B Board REV 07 710-023185 DW3932 LCC SIB Mezz SIB 1 REV 07 710-022594 DW4193 LCC SIB B Board REV 07 710-023185 DW3904 LCC SIB Mezz SIB 2 Copyright © 2018, Juniper Networks, Inc.
  • Page 355 SIB F2S 1/2 REV 05 710-022603 DW7849 F2S SIB B Board REV 05 710-023787 DW7525 NEO PMB SIB F2S 1/4 REV 05 710-022603 DW7927 F2S SIB B Board REV 05 710-023787 DW7556 F2S SIB Mezz Copyright © 2018, Juniper Networks, Inc.
  • Page 356 Address 0x70: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Midplane REV 05 710-022574 TS4027 SFC Midplane Jedec Code: 0x7fb0 EEPROM Version: 0x01 P/N: 710-022574 S/N: TS4027 Assembly ID: 0x0962 Assembly Version: 01.05 Copyright © 2018, Juniper Networks, Inc.
  • Page 357 RE-DUO-C2600-16G-S Routing Engine 1 REV 06 740-026942 RE-DUO-C2600-16G-S CB 0 REV 05 710-022606 CB-TXP-S CB 1 REV 09 710-022606 CB-TXP-S SIB F13 0 REV 04 750-024564 SIB-TXP-F13 SIB F13 3 REV 04 750-024564 SIB-TXP-F13 Copyright © 2018, Juniper Networks, Inc.
  • Page 358 REV 07 710-007529 T640-FPC3 PIC 0 REV 14 750-009567 PC-1XGE-XENPAK PIC 1 REV 16 750-007141 PC-10GE-SFP PIC 2 REV 12 750-009567 PC-1XGE-XENPAK FPC 6 REV 07 710-013035 T640-FPC3-ES PIC 0 REV 09 750-009567 PC-1XGE-XENPAK Copyright © 2018, Juniper Networks, Inc.
  • Page 359 PIC 0 REV 11 750-017405 PD-4XGE-XFP SIB 0 REV 07 710-022594 SIB-TXP-T1600-S SIB 1 REV 07 710-022594 SIB-TXP-T1600-S SIB 3 REV 07 710-022594 SIB-TXP-T1600-S SIB 4 REV 08 710-022594 SIB-TXP-T1600-S Fan Tray 0 FANTRAY-T-S Copyright © 2018, Juniper Networks, Inc.
  • Page 360 Rear Fan Tray Fan Tray 3 REV 02 760-024502 DR8270 Rear Fan Tray Fan Tray 4 REV 02 760-024502 DR8284 Rear Fan Tray Fan Tray 5 REV 06 760-024502 DV7813 Rear Fan Tray lcc0-re0: -------------------------------------------------------------------------- Copyright © 2018, Juniper Networks, Inc.
  • Page 361 Rev 07 740-027463 UM26368 ÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿÿ Routing Engine 0 REV 01 740-026942 737A-1064 RE-TXP-SFC-DUO-2600-16G Routing Engine 1 REV 01 740-026942 737A-1082 RE-TXP-SFC-DUO-2600-16G CB 0 REV 09 710-022606 DW6099 CB-TXP CB 1 REV 09 710-022606 DW6096 CB-TXP Copyright © 2018, Juniper Networks, Inc.
  • Page 362 PIC 2 REV 10 750-009450 HX6466 PC-1OC192-SON-SR2 SIB 0 REV 08 710-022594 DW8033 SIB-TXP-T1600-S SIB 1 REV 08 710-022594 DW8044 SIB-TXP-T1600-S SIB 2 REV 08 710-022594 DW8020 SIB-TXP-T1600-S SIB 3 REV 08 710-022594 DW8063 SIB-TXP-T1600-S Copyright © 2018, Juniper Networks, Inc.
  • Page 363 DW4217 SIB-TXP-T1600-S SIB 1 REV 07 710-022594 DW4213 SIB-TXP-T1600-S SIB 2 REV 07 710-022594 DW4189 SIB-TXP-T1600-S SIB 3 REV 07 710-022594 DW4173 SIB-TXP-T1600-S SIB 4 REV 07 710-022594 DW4201 SIB-TXP-T1600-S Fan Tray 0 FANTRAY-T-S Copyright © 2018, Juniper Networks, Inc.
  • Page 364 SFC Control Board CB 1 REV 15 710-022606 EH4379 SFC Control Board SPMB 0 BUILTIN SFC Switch CPU SPMB 1 BUILTIN SFC Switch CPU SIB F13 0 REV 10 750-035002 EM9305 F13 SIB 3D Copyright © 2018, Juniper Networks, Inc.
  • Page 365 EJ7026 F2S SIB 3D B Board REV 01 711-034979 EJ8273 F2S SIB 3D Mezz SIB F2S 3/0 REV 01 711-034977 EH9811 F2S SIB 3D B Board REV 01 711-034979 EH9892 F2S SIB 3D Mezz Copyright © 2018, Juniper Networks, Inc.
  • Page 366 CXP Module Xcvr 6 REV 01 740-047547 XB48FB05N CXP Module Fan Tray 0 Front Top Fan Tray Fan Tray 1 Front Bottom Fan Tray Fan Tray 2 Rear Fan Tray -- Rev 4 lcc2-re0: Copyright © 2018, Juniper Networks, Inc.
  • Page 367 CLEI code FRU model number Midplane REV 05 710-022574 CHAS-BP-TXP-S FPM Display REV 09 710-024027 CRAFT-TXP-S CIP 0 REV 12 710-023792 CIP-TXP-S CIP 1 REV 12 710-023792 CIP-TXP-S PEM 0 Rev 06 740-027463 IPUPAFGKTA PWR-TXP-7-60-DC-S Copyright © 2018, Juniper Networks, Inc.
  • Page 368 REV 16 750-035002 PROTOXCLEI SIB-TXP-3D-F13 Xcvr 0 REV 01 740-048813 Xcvr 1 REV 01 740-048813 Xcvr 2 REV 01 740-048813 Xcvr 3 REV 01 740-048813 Xcvr 4 REV 01 740-048813 Xcvr 5 REV 01 740-048813 Copyright © 2018, Juniper Networks, Inc.
  • Page 369 740-047547 CXP-TXP-3D SIB F13 12 REV 16 750-035002 PROTOXCLEI SIB-TXP-3D-F13 Xcvr 0 REV 01 740-047547 CXP-TXP-3D Xcvr 1 REV 01 740-047547 CXP-TXP-3D Xcvr 2 REV 01 740-047547 CXP-TXP-3D Xcvr 3 REV 01 740-047547 CXP-TXP-3D Copyright © 2018, Juniper Networks, Inc.
  • Page 370 PIC 0 REV 17 750-034624 IP9IAL2DAA PF-12XGE-SFPP PIC 1 REV 17 750-034624 IP9IAL2DAA PF-12XGE-SFPP FPC 5 REV 01 750-045173 IP9IAL4DAB T4000-FPC5-3D PIC 0 REV 17 750-034624 IP9IAL2DAA PF-12XGE-SFPP PIC 1 REV 17 750-034624 IP9IAL2DAA PF-12XGE-SFPP Copyright © 2018, Juniper Networks, Inc.
  • Page 371 Fan Tray 2 FANTRAY-TXP3D-LCC-R-S [Output Truncated] show chassis hardware detail (TX Matrix Plus Router with 3D SIBs) user@host> show chassis hardware detail sfc0-re0: -------------------------------------------------------------------------- Hardware inventory: Item Version Part number Serial number Description Chassis JN11CAAA4AHB Copyright © 2018, Juniper Networks, Inc.
  • Page 372 F2S SIB 3D Mezz SIB F2S 0/6 REV 01 711-034977 EH9763 F2S SIB 3D B Board REV 01 711-034979 EH9880 F2S SIB 3D Mezz SIB F2S 1/0 REV 01 711-034977 EH9757 F2S SIB 3D Copyright © 2018, Juniper Networks, Inc.
  • Page 373 REV 05 710-023321 EG9434 LCC Switch CPU SPMB 1 REV 05 710-023321 EH3878 LCC Switch CPU SIB 0 REV 01 750-041657 EH7997 LCC SIB 3D B Board REV 01 711-042424 EH7674 LCC SIB 3D Mezz Copyright © 2018, Juniper Networks, Inc.
  • Page 374 Xcvr 6 REV 01 740-047547 XB48FB043 CXP Module SIB 1 REV 01 750-041657 EH8012 LCC SIB 3D B Board REV 01 711-042424 EH7658 LCC SIB 3D Mezz Xcvr 0 REV 01 740-047547 XB48FB05E CXP Module Copyright © 2018, Juniper Networks, Inc.
  • Page 375 LCC SIB 3D Mezz Xcvr 0 REV 01 740-047547 XB34FB01Z CXP Module Xcvr 2 REV 01 740-047547 XB34FB013 CXP Module Xcvr 4 REV 01 740-047547 XB48FB04Z CXP Module Xcvr 6 REV 01 740-047547 XB48FB05N CXP Module Copyright © 2018, Juniper Networks, Inc.
  • Page 376 EJ2631 F13 SIB 3D B Board REV 01 711-035082 EJ3808 F13 SIB 3D Mezz P Board REV 01 711-043544 EJ2676 F13 SIB 3D Power SIB F2S 0/0 REV 01 711-034977 EH9829 F2S SIB 3D Copyright © 2018, Juniper Networks, Inc.
  • Page 377 XF0550 MX SCB CB 2 REV 03 710-021523 XD7455 MX SCB FPC 4 REV 02 750-028467 JR6127 MPC M 16x 10GE REV 02 711-029089 JX0129 AS PMB PIC 0 BUILTIN BUILTIN 4x 10GE(LAN) SFP+ Copyright © 2018, Juniper Networks, Inc.
  • Page 378 Xcvr 0 REV 01 740-035329 X12J00008 CFP-100G-SR10 FPC 5 REV 06 750-024884 JW9769 MPC Type 2 3D EQ REV 02 711-028401 JR6158 MPC PMB 2G Proto MIC 0 REV 05 750-028387 JR6197 3D 4x 10GE Copyright © 2018, Juniper Networks, Inc.
  • Page 379 Xcvr 3 REV 01 740-030589 S9AK450098 SFP+-10G-LPBK Xcvr 4 REV 01 740-030589 S99E270075 SFP+-10G-LPBK Xcvr 5 REV 01 740-030589 S9AK450093 SFP+-10G-LPBK Xcvr 6 REV 01 740-030589 S9AK450097 SFP+-10G-LPBK Xcvr 7 REV 01 740-030589 S9AK450095 SFP+-10G-LPBK Copyright © 2018, Juniper Networks, Inc.
  • Page 380 (QFX3500 Switches) user@switch> show chassis hardware models Hardware inventory: Item Version Part number Serial number FRU model number Routing Engine 0 BUILTIN BUILTIN FPC 0 REV 02 711-032234 EC4074 Power Supply 0 PSMI 2C 11-d65800 Copyright © 2018, Juniper Networks, Inc.
  • Page 381 AC AFO 1600W PSU Power Supply 1 REV 03 740-054405 1EDN5346300 AC AFO 1600W PSU Fan Tray 0 QFX10002 Fan Tray 0, Front to Back Airflow - AFO Fan Tray 1 QFX10002 Fan Tray 1, Copyright © 2018, Juniper Networks, Inc.
  • Page 382 REV 01 740-052307 APF16100071C30 QSFP+-40G-ACU7M Xcvr 20 740-038625 APF16290055004 QSFP+-40G-CU5M Xcvr 21 REV 01 740-038153 APF1622003970G QSFP+-40G-CU3M Xcvr 22 740-038624 APF16190036R90 QSFP+-40G-CU3M Xcvr 23 740-038624 APF16050030374 QSFP+-40G-CU3M Xcvr 24 REV 01 740-038153 APF162400318HC QSFP+-40G-CU3M Copyright © 2018, Juniper Networks, Inc.
  • Page 383 (QFabric Systems) user@switch> show chassis hardware interconnect-device interconnect1 Hardware inventory: Item Version Part number Serial number Description Chassis REV 07 QFX_olive Midplane REV 07 750-021261 BH0208188289 QFX Midplane CB 0 REV 07 750-021261 BH0208188289 QFXIC08-CB4S Copyright © 2018, Juniper Networks, Inc.
  • Page 384 FPC 3 REV 13 750-036844 EG5074 REV 09 711-030686 EG4064 SNG PMB PIC 1 REV 10 750-031903 EG0325 SNG Load FPC 5 REV 06 750-036844 EH3198 PIC 0 REV 14 750-031913 EG5134 24x 10GE(LAN) SFP+ Copyright © 2018, Juniper Networks, Inc.
  • Page 385 High Capacity AC PSM PSM 1 Rev 01 740-048334 1GB43360099 High Capacity AC PSM PSM 2 Rev 01 740-048334 1GB43360050 High Capacity AC PSM PSM 3 Rev 01 740-048334 1GB43360095 High Capacity AC PSM Copyright © 2018, Juniper Networks, Inc.
  • Page 386 SIB 0 REV 07 750-030631 PROTOXCLEI SIB-I-PTX5008 SIB 1 REV 07 750-030631 PROTOXCLEI SIB-I-PTX5008 SIB 2 REV 07 750-030631 PROTOXCLEI SIB-I-PTX5008 SIB 3 REV 07 750-030631 PROTOXCLEI SIB-I-PTX5008 SIB 4 REV 07 750-030631 PROTOXCLEI SIB-I-PTX5008 Copyright © 2018, Juniper Networks, Inc.
  • Page 387 REV 09 750-030653 IPUCA7DCAA CCG-PTX-S CCG 1 REV 09 750-030653 IPUCA7DCAA CCG-PTX-S show chassis hardware detail (PTX5000 Packet Transport Router) user@host> show chassis hardware detail Hardware inventory: Item Version Part number Serial number Description Copyright © 2018, Juniper Networks, Inc.
  • Page 388 Xcvr 15 REV 01 740-031980 B11J00687 SFP+-10G-SR Xcvr 16 REV 01 740-031980 193363A00738 SFP+-10G-SR Xcvr 18 REV 01 740-031980 AK80MQX SFP+-10G-SR Xcvr 19 REV 01 740-021309 J08C17257 SFP+-10G-LR Xcvr 22 REV 01 740-031980 B11J00730 SFP+-10G-SR Copyright © 2018, Juniper Networks, Inc.
  • Page 389 Clock Generator show chassis hardware detail (PTX5000 Packet Transport Router with FPC2-PTX-P1A) user@host> show chassis hardware detail Hardware inventory: Item Version Part number Serial number Description Chassis JN1204FC0AJA PTX5000 Midplane REV 11 750-035893 ACAB8038 Midplane-8S Copyright © 2018, Juniper Networks, Inc.
  • Page 390 Hardware inventory: Item Version Part number Serial number FRU model number Midplane REV 16 750-035893 ACRA1350 CHAS-MP-PTX5000-S REV 12 760-030647 BBBD5625 CRAFT-PTX5000-S PDU 0 Rev 01 740-048338 1GB83360005 PDU2-PTX-AC-W Copyright © 2018, Juniper Networks, Inc.
  • Page 391 Address 0x10: 00 00 00 00 37 34 30 2d 30 33 32 30 31 39 00 00 Address 0x20: 53 2f 4e 20 55 45 30 30 30 33 00 00 00 1d 0b 07 Copyright © 2018, Juniper Networks, Inc.
  • Page 392 Back Airflow - AFO show chassis hardware extensive (PTX5000 with Control Board 2) user@host> show chassis hardware grep CB CB 0 REV 06 750-055537 ACLZ9541 Control Board 2 CB 1 REV 06 750-055537 ACLY5329 Control Board 2 Copyright © 2018, Juniper Networks, Inc.
  • Page 393 Address 0x60: 00 00 00 00 00 00 30 34 00 ff ff ff ff ff ff ff Address 0x70: ff ff ff 60 00 00 00 00 00 00 00 00 00 00 00 00 MIC 0 REV 06 750-037214 ZW3574 AS-MSC Copyright © 2018, Juniper Networks, Inc.
  • Page 394 Power Supply 1 REV 03 740-041741 1GA24081097 JPSU-650W-AC-AFO Fan Tray 0 ACX5K Fan Tray 0, Front to Back Airflow - AFO Fan Tray 1 ACX5K Fan Tray 1, Front to Back Airflow - AFO Copyright © 2018, Juniper Networks, Inc.
  • Page 395 740-041741 CMUPABHBAA JPSU-650W-AC-AFO Fan Tray 0 ACX5K-FAN Fan Tray 1 ACX5K-FAN Fan Tray 2 ACX5K-FAN Fan Tray 3 ACX5K-FAN Fan Tray 4 ACX5K-FAN show chassis hardware models (ACX5048 Router) user@host> show chassis hardware models Copyright © 2018, Juniper Networks, Inc.
  • Page 396 Hard Disk 511 MB QEMU HARDDISK QM00003 Hard Disk 1023 MB QEMU HARDDISK QM00004 Hard Disk usb0 (addr 1) product 0x0000 0 vendor 0x0000 uhub1 usb0 (addr 2) product 0x0020 32 vendor 0x8087 uhub2 Copyright © 2018, Juniper Networks, Inc.
  • Page 397 ACX5K-FAN show chassis hardware (ACX500 Router) user@host> show chassis hardware Hardware inventory: Item Version Part number Serial number Description Chassis VJ0214510035 ACX500-AC Midplane REV 01 650-055932 VJ0214510035 ACX500-AC Routing Engine BUILTIN BUILTIN Routing Engine Copyright © 2018, Juniper Networks, Inc.
  • Page 398 Address 0x70: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Midplane REV 01 650-055932 VJ0214510035 ACX500-AC Jedec Code: 0x7fb0 EEPROM Version: 0x02 P/N: 650-055932 S/N: VJ0214510035 Copyright © 2018, Juniper Networks, Inc.
  • Page 399 Address 0x70: 00 00 00 00 00 00 00 00 64 20 b5 c0 60 af 21 38 PIC 1 BUILTIN BUILTIN 4x 1GE(LAN) SFP, RJ45 Xcvr 0 REV 01 740-011613 PF30K0L SFP-SX MIC 2 BUILTIN BUILTIN MS BUILTIN Jedec Code: 0x0000 EEPROM Version: 0x00 Copyright © 2018, Juniper Networks, Inc.
  • Page 400 Hardware inventory: Item Version Part number Serial number FRU model number Midplane REV 01 650-055932 VJ0214510035 ACX500-AC Routing Engine BUILTIN BUILTIN FEB 0 BUILTIN BUILTIN FPC 0 BUILTIN BUILTIN Copyright © 2018, Juniper Networks, Inc.
  • Page 401: Show Chassis Environment Fpc

    Universal Edge <satellite [fpc-slot slot-id |device-alias alias-name] Routers) Syntax (QFX Series) show chassis environment fpc <fpc-slot> interconnect-device name Syntax (OCX Series) show chassis environment fpc <fpc-slot> Syntax (PTX3000 show chassis environment fpc <fpc-slot> Series) Copyright © 2018, Juniper Networks, Inc.
  • Page 402 0 through 3, when T640 routers are connected to a TX Matrix router in a routing matrix. 0 through 3, when T1600 routers are connected to a TX Matrix Plus router in a routing matrix. Copyright © 2018, Juniper Networks, Inc.
  • Page 403 EX Series switches: EX3200 switches and EX4200 standalone switches—Replace slot with 0. EX4200 switches in a Virtual Chassis configuration—Replace with a value slot from 0 through 9 (switch’s member ID). Copyright © 2018, Juniper Networks, Inc.
  • Page 404 (TX Matrix Plus Router) on page 422 show chassis environment fpc (QFX Series and OCX Series) on page 423 show chassis environment fpc interconnect-device (QFabric Systems) on page 423 show chassis environment fpc 5(PTX3000 Packet Transport Router) on page 424 Copyright © 2018, Juniper Networks, Inc.
  • Page 405: Table 28: Show Chassis Environment Fpc Output Fields

    The PTX Series Packet Transport Routers, and the MX2010, MX2020, and MX2008 routers include exhaust temperatures for multiple zones ( Exhaust A Exhaust B Temperature Bottom (T Series routers only) Temperature of the air flowing past the bottom of the FPC. Copyright © 2018, Juniper Networks, Inc.
  • Page 406 2.5 V 2471 mV 3.3 V 3293 mV 5.0 V 4930 mV 3.3 V bias 3296 mV 1.2 V Rocket IO 1205 mV 1.5 V Rocket IO 1501 mV Power B-Board 1.2 V 1214 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 407 State Online Temperature Intake 27 degrees C / 80 degrees F Temperature Exhaust 38 degrees C / 100 degrees F Temperature MMB1 31 degrees C / 87 degrees F Power: 1.5 V 1487 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 408 49 degrees C / 120 degrees F Temperature MQ 0 Chip 49 degrees C / 120 degrees F Temperature MQ 1 TSen 49 degrees C / 120 degrees F Temperature MQ 1 Chip 52 degrees C / 125 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 409 1000 mV AS-VDD3V3-zl2004 3294 mV AS-VDD_1V5A-zl2004 1500 mV AS-VDD_1V5B-zl2004 1498 mV AS-LU0_1V0-zl2004 1003 mV AS-LU1_1V0-zl2004 1000 mV AS-MQ0_1V0-zl2004 1000 mV AS-MQ1_1V0-zl2004 995 mV AS-LU2_1V0-zl2004 1002 mV AS-LU3_1V0-zl2004 997 mV AS-MQ2_1V0-zl2004 1000 mV AS-MQ3_1V0-zl2004 998 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 410 50 degrees C / 122 degrees F Temperature MQ 1 Chip 55 degrees C / 131 degrees F Temperature MQ 2 TSen 50 degrees C / 122 degrees F Temperature MQ 2 Chip 47 degrees C / 116 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 411 3300 mV AS-VDD1V8-zl2006 1805 mV AS-VDD2V5-zl2006 2505 mV AS-AVDD1V0-zl2004 998 mV AS-PCIE_1V0-zl2004 999 mV AS-VDD3V3-zl2004 3303 mV AS-VDD_1V5A-zl2004 1497 mV AS-VDD_1V5B-zl2004 1497 mV AS-LU0_1V0-zl2004 998 mV AS-LU1_1V0-zl2004 1003 mV AS-MQ0_1V0-zl2004 998 mV AS-MQ1_1V0-zl2004 998 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 412 Temperature LU 1 TCAM Chip 42 degrees C / 107 degrees F Temperature LU 1 TSen 39 degrees C / 102 degrees F Temperature LU 1 Chip 46 degrees C / 114 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 413 1503 mV AS-VDD_1V5B-zl2004 1502 mV AS-LU0_1V0-zl2004 996 mV AS-LU1_1V0-zl2004 999 mV AS-MQ0_1V0-zl2004 997 mV AS-MQ1_1V0-zl2004 999 mV AS-LU2_1V0-zl2004 997 mV AS-LU3_1V0-zl2004 998 mV AS-MQ2_1V0-zl2004 1000 mV AS-MQ3_1V0-zl2004 1000 mV AS-PMB_1V1-zl2006 1102 mV I2C Slave Revision Copyright © 2018, Juniper Networks, Inc.
  • Page 414 1200 mV MPC-XL1_XR0_0V9-vt273m 899 mV MPC-XL1_XR1_0V9-vt273m 899 mV MPC-XL1_0V9-vt273m 900 mV MPC-XL1_AVDD_1V0-vt273m 1000 mV MPC-XL1_VDD_1V5-vt273m 1501 mV MPC-XL1_XR_1V2-vt273m 1199 mV MPC-PMB-1V05-ltc2978 1049 mV MPC-PMB-1V5-ltc2978 1500 mV MPC-PMB-2V5-ltc2978 2500 mV MPC-PMB-3V3-ltc2978 3298 mV I2C Slave Revision Copyright © 2018, Juniper Networks, Inc.
  • Page 415 Temperature EA3_HMC2 Logic die 52 degrees C / 125 degrees F Temperature EA3_HMC2 DRAM botm 49 degrees C / 120 degrees F Power MPC-EA0_0V9-vt1527mb 950 mV MPC-EA1_0V9-vt1527mb 950 mV MPC-EA2_0V9-vt1527mb 925 mV MPC-EA3_0V9-vt1527mb 924 mV MAX20751-1V0 1020 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 416 46 degrees C / 114 degrees F Temperature Exhaust B 38 degrees C / 100 degrees F Temperature QX 0 TSen 49 degrees C / 120 degrees F Temperature QX 0 Chip 52 degrees C / 125 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 417 Temperature IA 1 Chip 49 degrees C / 120 degrees F Power 1.5 V 1492 mV 2.5 V 2507 mV 3.3 V 3306 mV 1.8 V PFE 0 1801 mV 1.8 V PFE 1 1804 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 418 58 degrees C / 136 degrees F Temperature IA 1 TSensor 48 degrees C / 118 degrees F Temperature IA 1 Chip 53 degrees C / 127 degrees F Power 1.5 V 1479 mV 2.5 V 2542 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 419 45 degrees C / 113 degrees F Temperature IA 0 Chip 47 degrees C / 116 degrees F Temperature IA 1 TSensor 37 degrees C / 98 degrees F Temperature IA 1 Chip 42 degrees C / 107 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 420 60 degrees C / 140 degrees F Temperature LU 3 TSen 46 degrees C / 114 degrees F Temperature LU 3 Chip 71 degrees C / 159 degrees F Temperature XM 0 TSen 46 degrees C / 114 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 421 29 degrees C / 84 degrees F FPC 0 Exhaust-A Temp Sensor56 degrees C / 132 degrees F FPC 0 Exhaust-B Temp Sensor44 degrees C / 111 degrees F FPC 0 EA0 Chip 58 degrees C / 136 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 422 1037 mV UCD9090_0-CH_7-EA1_2V5 2499 mV UCD9090_0-CH_8-EA1_1V5 1510 mV UCD9090_0-CH_9-PVCC 797 mV UCD9090_0-CH_10-PVNN 991 mV UCD9090_1-CH_1-EA2_PLL_ 1008 mV UCD9090_1-CH_2-EA2_1V4 1009 mV UCD9090_1-CH_3-EA2_2V5 2499 mV UCD9090_1-CH_4-EA2_1V5 1513 mV UCD9090_1-CH_5-1V0_PFPL 1009 mV UCD9090_1-CH_6-V1P1 1075 mV UCD9090_1-CH_7-V1P5 1531 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 423 FPC 1 EA1_HMC2 DRAM botm 82 degrees C / 179 degrees F FPC 1 EA2_HMC0 Logic die 62 degrees C / 143 degrees F FPC 1 EA2_HMC0 DRAM botm 59 degrees C / 138 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 424 1000 mV LTC3887-EA0-VDD1V0-CH1 1001 mV LTC3887-EA0-XR-VDD0V9 899 mV LTC3887-EA0-XR-VDD1V2 1200 mV LTC3887-EA0-HM1-VDD0V9 899 mV LTC3887-EA0-HM-VDD1V2 1199 mV LTC3887-EA0-HM-VDDM1V2 1199 mV LTC3887-EA1-VDD0V9-RAIL 948 mV LTC3887-EA1-VDD0V9-DEV0 950 mV LTC3887-EA1-VDD0V9-DEV0 950 mV LTC3887-EA1-VDD0V9-DEV1 951 mV LTC3887-EA1-VDD0V9-DEV1 951 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 425 FPC 1 EA1_HMC0 Logic die 59 degrees C / 138 degrees F FPC 1 EA1_HMC0 DRAM botm 56 degrees C / 132 degrees F FPC 1 EA1_HMC1 Logic die 60 degrees C / 140 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 426 25625 mW EA1 HMC Core 0.9V 897 mV 9732 mA 8731 mW EA1 1.2V 1197 mV 16011 mA 19167 mW EA0_PLL_1V0 1006 mV 0 mA 0 mW EA0_1V04 1032 mV 0 mA 0 mW Copyright © 2018, Juniper Networks, Inc.
  • Page 427 FPC 2 EA1_XR1 Temp Sensor 38 degrees C / 100 degrees F FPC 2 EA2 Temp Sensor 41 degrees C / 105 degrees F FPC 2 EA2_XR0 Temp Sensor 46 degrees C / 114 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 428 980 mV 3686 mA 3612 mW VDD 1.8V 1805 mV 895 mA 1616 mW PVCC 870 mV 0 mA 0 mW PVNN 1016 mV 0 mA 0 mW V1P0 1000 mV 0 mA 0 mW Copyright © 2018, Juniper Networks, Inc.
  • Page 429 1054 mV 0 mA 0 mW EA4_2V5 2548 mV 0 mA 0 mW EA4_1V5 1516 mV 0 mA 0 mW EA5_PLL_1V0 1012 mV 0 mA 0 mW EA5_1V04 1054 mV 0 mA 0 mW Copyright © 2018, Juniper Networks, Inc.
  • Page 430 FPC 5 EA4_HMC2 DRAM botm 79 degrees C / 174 degrees F FPC 5 EA5_HMC0 Logic die 68 degrees C / 154 degrees F FPC 5 EA5_HMC0 DRAM botm 65 degrees C / 149 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 431 1045 mV 0 mA 0 mW EA2_2V5 2503 mV 0 mA 0 mW EA2_1V5 1490 mV 0 mA 0 mW EA3_PLL_1V0 1009 mV 0 mA 0 mW EA3_1V04 1041 mV 0 mA 0 mW Copyright © 2018, Juniper Networks, Inc.
  • Page 432 3.3 V 3340 mV 5.0 V 5023 mV 1.8 V bias 1782 mV 3.3 V bias 3277 mV 5.0 V bias 4989 mV 8.0 V bias 7289 mV BUS Revision FPC 2 status: State Online Copyright © 2018, Juniper Networks, Inc.
  • Page 433 1000 mV 1.0 V PFE1 1002 mV 1.0 V PFE0 * 995 mV 1.0 V PFE1 * 995 mV 1.8 V PFE 0 1788 mV 1.8 V PFE 1 1789 mV 2.5 V 2482 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 434 1002 mV 1.2 V bias 1201 mV 1.8 V 1785 mV 2.5 V 2485 mV 3.3 V 3288 mV 3.3 V bias 3285 mV 12.0 V A 10412 mV 12.0 V B 10515 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 435 39 degrees C / 102 degrees F Temperature Bottom 38 degrees C / 100 degrees F Power 1.8 V 1804 mV 1.8 V bias 1802 mV 3.3 V 3294 mV 3.3 V bias 3277 mV 5.0 V bias 5008 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 436 66 degrees C / 150 degrees F PFE0 LU1 69 degrees C / 156 degrees F PFE0 LU2 68 degrees C / 154 degrees F PFE1 LU1 42 degrees C / 107 degrees F Power 1 1.0 V 998 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 437 LMB2 PFE1 LU1 AVDD1V0 996 mV LMB2 PFE1 LU1 VDD1V0 1010 mV LMB2 VDD12V0 10528 mV PMB 1.05v 1050 mV PMB 1.5v 1499 mV PMB 2.5v 2500 mV PMB 3.3v 3300 mV Bus Revision Copyright © 2018, Juniper Networks, Inc.
  • Page 438 5.0 V bias 5018 mV 5.0 V TOP 5037 mV 8.0 V bias 7223 mV Power (Base/PMB/MMB) 1.2 V 1205 mV 1.5 V 1503 mV 5.0 V BOT 5084 mV 12.0 V TOP Base 11775 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 439 Power BIAS 3V3 3330 mV VDD 3V3 3300 mV VDD 2V5 2502 mV VDD 1V5 1496 mV VDD 1V2 1194 mV VDD 1V0 1000 mV SW0 VDD 1020 mV SW0 CVDD 1V025 1032 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 440 1.0v 999 mV 0.9v 900 mV 0.9v 900 mV PFE1 1.5v 1499 mV PFE1 1.0v 999 mV 0.9v 899 mV 0.9v 900 mV PFE2 1.5v 1500 mV PFE2 1.0v 1000 mV 0.9v 900 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 441 897 mV PFE2 1.0v 999 mV PFE2 1.5v 1499 mV FPC Base 1.0v 1000 mV FPC Base 1.2v 1199 mV 0.9v 898 mV 0.9v 898 mV PFE5 1.0v 1000 mV PFE5 1.5v 1500 mV Copyright © 2018, Juniper Networks, Inc.
  • Page 442 39 degrees C / 102 degrees F Power PE0 Core 0.9V 898 mV 29351 mA 26421 mW PE0 HMC0 Core 0.9V 899 mV 9734 mA 8750 mW PE1 Core 0.9V 873 mV 28539 mA 24933 mW Copyright © 2018, Juniper Networks, Inc.
  • Page 443 1200 mV 1185 mA 1421 mW PE5 HMC Core 0.9V 899 mV 8718 mA 7843 mW PE4,5 HMC Serdes 1.2V 1199 mV 21125 mA 25343 mW LCPU platform 1.1V 1099 mV 3777 mA 4156 mW Copyright © 2018, Juniper Networks, Inc.
  • Page 444 FPC 5 PE0 Temp Sensor 47 degrees C / 116 degrees F FPC 5 PE1 Temp Sensor 49 degrees C / 120 degrees F FPC 5 PE2 Temp Sensor 53 degrees C / 127 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 445 4078 mW VDD 2.5V 2449 mV 3539 mA 8671 mW VDD 3.3V 3299 mV 8082 mA 26656 mW 12311 mV 31124 mA 385270 mW show chassis environment fpc (PTX10016 router) user@host> show chassis environment fpc Copyright © 2018, Juniper Networks, Inc.
  • Page 446 PHY VDD A 1.0V 1000 mV 14953 mA 14953 mW BCM Core 1.0V 1000 mV 7648 mA 7648 mW BCM PEX 1.0V 1000 mV 3531 mA 3531 mW HMC Core 1.2V 1200 mV 1234 mA 1476 mW Copyright © 2018, Juniper Networks, Inc.
  • Page 447 PE1 Serdes 1.0V 1020 mV 28265 mA 28828 mW PE2 Serdes 1.0V 1019 mV 28406 mA 29000 mW LCPU Platform 1.1V 1099 mV 3000 mA 3300 mW LCPU Core 1.0V 1000 mV 7937 mA 7937 mW Copyright © 2018, Juniper Networks, Inc.
  • Page 448 BCM & PEX Serdes 1.0V 999 mV 4062 mA 4062 mW 12417 mV 51659 mA 643215 mW show chassis environment FPC 1 (MX Routers with Media Services Blade [MSB]) user@switch> show chassis environment fpc 1 Copyright © 2018, Juniper Networks, Inc.
  • Page 449 FPC 1 Intake Temp Sensor 30 degrees C / 86 degrees F FPC 1 Exhaust-A Temp Sensor60 degrees C / 140 degrees F FPC 1 Exhaust-B Temp Sensor50 degrees C / 122 degrees F Power I2C Slave Revision Copyright © 2018, Juniper Networks, Inc.
  • Page 450: Show Chassis Environment Monitored

    MX2020, and MX2008 routers only) (Optional) Display chassis information for monitored temperatures in the specified member of the Virtual Chassis. Replace member-id with the value 0 or 1. Required Privilege view Level Related show chassis environment Documentation Chassis-Level Feature Guide Copyright © 2018, Juniper Networks, Inc.
  • Page 451: Table 29: Show Chassis Environment Monitored Output Fields

    40 degrees C / 104 degrees F FPC 2 PMB CPU 67 degrees C / 152 degrees F FPC 2 Exhaust 40 degrees C / 104 degrees F FPC 2 Intake 33 degrees C / 91 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 452 Routing Engine 1 CPU Present SFB 0 Intake-Zone0 46 degrees C / 114 degrees F SFB 0 Exhaust-Zone1 38 degrees C / 100 degrees F SFB 0 IntakeA-Zone0 35 degrees C / 95 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 453 37 degrees C / 98 degrees F SFB 7 SFB-XF2-Zone1 43 degrees C / 109 degrees F SFB 7 SFB-XF1-Zone0 47 degrees C / 116 degrees F SFB 7 SFB-XF0-Zone0 52 degrees C / 125 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 454 FPC 9 LU 2 TSen 51 degrees C / 123 degrees F FPC 9 LU 2 Chip 47 degrees C / 116 degrees F FPC 9 LU 3 TSen 51 degrees C / 123 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 455 39 degrees C / 102 degrees F SFB 1 Exhaust-Zone0 48 degrees C / 118 degrees F SFB 1 SFB-XF2-Zone1 60 degrees C / 140 degrees F SFB 1 SFB-XF1-Zone0 64 degrees C / 147 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 456 FPC 0 LU 3 TSen 56 degrees C / 132 degrees F FPC 0 LU 3 Chip 52 degrees C / 125 degrees F FPC 0 MQ 0 TSen 49 degrees C / 120 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 457 FPC 3 MQ 1 TSen 50 degrees C / 122 degrees F FPC 3 MQ 1 Chip 55 degrees C / 131 degrees F FPC 3 MQ 2 TSen 50 degrees C / 122 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 458 FPC 6 MQ 3 TSen 51 degrees C / 123 degrees F FPC 6 MQ 3 Chip 51 degrees C / 123 degrees F FPC 7 Intake 42 degrees C / 107 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 459 FPC 10 Exhaust B 54 degrees C / 129 degrees F FPC 10 LU 0 TSen 53 degrees C / 127 degrees F FPC 10 LU 0 Chip 54 degrees C / 129 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 460 FPC 13 LU 1 Chip 54 degrees C / 129 degrees F FPC 13 LU 2 TSen 50 degrees C / 122 degrees F FPC 13 LU 2 Chip 48 degrees C / 118 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 461 FPC 16 LU 3 Chip 50 degrees C / 122 degrees F FPC 16 MQ 0 TSen 51 degrees C / 123 degrees F FPC 16 MQ 0 Chip 50 degrees C / 122 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 462 FPC 19 MQ 1 Chip 64 degrees C / 147 degrees F FPC 19 MQ 2 TSen 58 degrees C / 136 degrees F FPC 19 MQ 2 Chip 59 degrees C / 138 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 463 67 degrees C / 152 degrees F ADC 14 Intake 49 degrees C / 120 degrees F ADC 14 Exhaust 57 degrees C / 134 degrees F ADC 14 ADC-XF1 68 degrees C / 154 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 464 26 degrees C / 78 degrees F SFB 2 Inlet1 27 degrees C / 80 degrees F SFB 2 Exhaust2 28 degrees C / 82 degrees F SFB 2 SFB2-PF-local 27 degrees C / 80 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 465 52 degrees C / 125 degrees F FPC 1 Exhaust B 44 degrees C / 111 degrees F FPC 1 EA0 TSen 55 degrees C / 131 degrees F FPC 1 EA0 Chip 48 degrees C / 118 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 466 FPC 7 MQ 0 Chip 55 degrees C / 131 degrees F FPC 7 QX 1 TSen 41 degrees C / 105 degrees F FPC 7 QX 1 Chip 42 degrees C / 107 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 467 FPC 1 EA1_HMC2 Logic die 59 degrees C / 138 degrees F FPC 1 EA1_HMC2 DRAM botm 56 degrees C / 132 degrees F FPC 1 EA2_HMC0 Logic die 64 degrees C / 147 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 468 FPC 2 EA2_HMC1 Logic die 0 degrees C / 32 degrees F FPC 2 EA2_HMC1 DRAM botm 0 degrees C / 32 degrees F FPC 2 EA2_HMC2 Logic die 0 degrees C / 32 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 469 FPC 5 EA3_HMC0 Logic die 74 degrees C / 165 degrees F FPC 5 EA3_HMC0 DRAM botm 71 degrees C / 159 degrees F FPC 5 EA3_HMC1 Logic die 73 degrees C / 163 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 470 28 degrees C / 82 degrees F SFB 2 Exhaust-B 26 degrees C / 78 degrees F SFB 2 PF0 30 degrees C / 86 degrees F SFB 2 PF1 30 degrees C / 86 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 471 27 degrees C / 80 degrees F SFB 3 Exhaust-B 28 degrees C / 82 degrees F SFB 3 PF0 31 degrees C / 87 degrees F SFB 3 PF1 31 degrees C / 87 degrees F Copyright © 2018, Juniper Networks, Inc.
  • Page 472: Request Chassis Fpc Optical-Module Firmware-Upgrade

    When you enter the command, you are provided feedback on the status of your request. Sample Output request chassis fpc optical-module firmware-upgrade user@host> request chassis fpc optical-module firmware-upgrade fpc-slot 4 IPLC 2 upgrade finished Copyright © 2018, Juniper Networks, Inc.
  • Page 473: Request Chassis Fpc Optical-Module Amplifier-Chain Ila Firmware-Upgrade

    When you enter the command, you are provided feedback on the status of your request. Sample Output request chassis fpc optical-module amplifier-chain ila firmware-upgrade user@host> request chassis fpc optical-module amplifier-chain ila firmware-upgrade fpc-slot 3 ila-number 0 IPLC 3 upgrade finished user@host> Copyright © 2018, Juniper Networks, Inc.
  • Page 474: Request Chassis Fpc Optical-Module Amplifier-Chain Ila Soft-Reset

    When you enter the command, you are provided feedback on the status of your request. Sample Output request chassis fpc optical-module amplifier-chain ila soft-reset user@host> request chassis fpc optical-module amplifier-chain ila soft-reset fpc-slot 3 ila-number Reset command was successfully issued to the requested ILA Copyright © 2018, Juniper Networks, Inc.
  • Page 475: Request Chassis Fpc Optical-Module Amplifier-Chain Ila Hard-Reset

    When you enter the command, you are provided feedback on the status of your request. Sample Output request chassis fpc optical-module amplifier-chain ila hard-reset user@host> request chassis fpc optical-module amplifier-chain ila hard-reset fpc-slot 3 ila-number Reset command was successfully issued to the requested ILA Copyright © 2018, Juniper Networks, Inc.
  • Page 476: Show Chassis Fpc Optical-Properties Amplifier-Topology

    Displays the name of the device it is connected to. Sample Output show chassis fpc optical-properties amplifier-topology user@host> show chassis fpc optical-properties amplifier-topology fpc-slot 3 IPLC Amplifier Topology Information Name IP Addr/Subnet Reachable Connected To Anchor IPLC 10.0.0.10/255.255.255.0 Yes ILA-0 10.0.0.11/255.255.255.0 Yes IPLC-3 Copyright © 2018, Juniper Networks, Inc.
  • Page 477: Show Chassis Fpc Optical-Properties Amplifier-Chain Ila Summary

    Number assigned to the optical ILA. ILA Name Name of the optical ILA. ILA Position Position of the optical ILA in the amplifier chain. This value can change if optical ILAs are added or removed from the amplifier chain. Copyright © 2018, Juniper Networks, Inc.
  • Page 478 Displays how many power supplies and fans are plugged in. Fan Speed (Fan 0/1/2) Fan speed. System Mode (auto/manual) System mode: auto or manual. The auto mode is the default. The manual mode is available only for debug purposes. Copyright © 2018, Juniper Networks, Inc.
  • Page 479 Power and Fan Plug Status (Fan 0/1/2, Power 0/1) Fan0: 1 Fan1: 1 Fan2: 1 Power0: 0 Power1: 1 Fan Speed (Fan 0/1/2) 9984 / 9984 / 10752 System Mode (auto/manual) Auto Firmware Upgrade Status (none/in progress/done) Status: Successful Percent: 0 Copyright © 2018, Juniper Networks, Inc.
  • Page 480: Table 32: Show Chassis Fpc Optical-Properties Amplifier-Chain Ila Edfa Output

    Table 32: show chassis fpc optical-properties amplifier-chain ila edfa Output Fields Field Name Field Description edfaIndex Index of the EDFA in the optical ILA (1 or 2). Manufacture information Displays the EDFA’s manufacturing information. edfaModuleType Name of the module. edfaPartNumber EDFA part number. Copyright © 2018, Juniper Networks, Inc.
  • Page 481 (0.01dBm) The input optical power. The unit is dBm. edfaOutputPower (0.01dBm) The output optical power. The unit is dBm. edfaDownstreamInputPower (0.01dBm) Input power of the optical ILA following the next optical span. Copyright © 2018, Juniper Networks, Inc.
  • Page 482 (0.01dBm) -250 ILA EDFA-B-A Information edfaIndex Manufacture information EDFA_MFG edfaModuleType ILA_EDFA edfaPartNumber EDFA128ILAJUP01-2 edfaSerialNumber B6904420 edfaMfgDate 2016-03-09 edfaCaliDate 2016-03-09 edfaFirmwareVer 1.03.0001 edfaHardwareVer 1.00.0002 edfaMode edfaGainSetting (0.01dBm) 1010 edfaTilt (0.01dBm) edfaWorkingStatus Normal, APR deactivated Copyright © 2018, Juniper Networks, Inc.
  • Page 483 Chapter 12: Operational Commands edfaAprEnable Enabled edfaWorkRange Low Gain edfaActualGain (0.01dBm) 1003 edfaCaseTemperature (C) 34.30 edfaPumpTemperature (C) 25.70 edfaAse (0.01dBm) -1498 edfaUpstreamOutputPower (0.01dBm) edfaInputPower (0.01dBm) -1054 edfaOutputPower (0.01dBm) edfaDownstreamInputPower (0.01dBm) -1086 edfaInputLOSThreshold (0.01dBm) -3950 edfaOutputLOSThreshold (0.01dBm) -250 Copyright © 2018, Juniper Networks, Inc.
  • Page 484: Table 33: Show Chassis Fpc Optical-Properties Amplifier-Chain Ila Osc Output

    The OSC power in dBm for (OSC transmitted) for port A or B. oscDropPowerValue (0.01dBm) The OSC power in dBm for (OSC received) for port A or B. oscAddLOSThreshold (0.01dBm) The OSC loss of signal (LOS) alarm threshold (OSC transmitted) for port A or B. Copyright © 2018, Juniper Networks, Inc.
  • Page 485 Manufacture information node ILA OSC-A Information oscEnable oscAddPowerValue (0.01dBm) oscDropPowerValue (0.01dBm) -893 oscAddLOSThreshold (0.01dBm) oscDropLOSThreshold (0.01dBm) ILA OSC-B Information oscIndex Manufacture information node ILA OSC-B Information oscEnable oscAddPowerValue (0.01dBm) oscDropPowerValue (0.01dBm) -823 oscAddLOSThreshold (0.01dBm) oscDropLOSThreshold (0.01dBm) Copyright © 2018, Juniper Networks, Inc.
  • Page 486: Table 34: Show Chassis Fpc Optical-Properties Amplifier-Chain Ila Voa Output

    VOA information for A (1) or B (2). voaAttenuation (0.01db) Displays the VOA value (dB). Sample Output show chassis fpc optical-properties amplifier-chain ila voa user@host> show chassis fpc optical-properties amplifier-chain ila voa fpc-slot 3 ila-number 0 Copyright © 2018, Juniper Networks, Inc.
  • Page 487 Chapter 12: Operational Commands ILA VOA-A Information voaIndex voaAttenuation (0.01db) ILA VOA-B Information voaIndex voaAttenuation (0.01db) Copyright © 2018, Juniper Networks, Inc.
  • Page 488: Table 35: Show Chassis Fpc Optical-Properties Amplifier-Chain Ila Alarms Output

    ILA Active Alarms Alarms that are active (see Table 36 on page 473 for alarm descriptions and corrective actions). Table 36 on page 473 describes the optical ILA alarms and provides the corrective action. Copyright © 2018, Juniper Networks, Inc.
  • Page 489: Table 36: Alarm Descriptions

    IPLC fpc-slot ILA ila-number EDFA A-B the EDFA case temperature is above below 80° C, the alarm is cleared. Case temperature 80° C, an alarm is triggered. A-B is the A to B direction (for example, east to west). Copyright © 2018, Juniper Networks, Inc.
  • Page 490 1.5 dB of the threshold greater than the threshold value, the Input LOS for the minimum input power, an alarm alarm is cleared. is triggered. A-B is the A to B direction (for example, east to west). Copyright © 2018, Juniper Networks, Inc.
  • Page 491 20° C or and 30° C, the alarm is cleared. Pump0 Temperature greater than 30° C, an alarm is triggered. B-A is the B to A direction (for example, west to east). Copyright © 2018, Juniper Networks, Inc.
  • Page 492 Table 36 on page 473 describes the optical ILA alarms and provides the corrective action. Sample Output show chassis fpc optical-properties amplifier-chain ila alarms user@host> show chassis fpc optical-properties amplifier-chain ila alarms fpc-slot 3 ila-number Copyright © 2018, Juniper Networks, Inc.
  • Page 493 Chapter 12: Operational Commands ILA Active Alarms IPLC 3 ILA 0 Power 0 abnormal Copyright © 2018, Juniper Networks, Inc.
  • Page 494: Table 37: Show Chassis Fpc Optical-Properties Pm-Current Output Fields

    Table 37: show chassis fpc optical-properties pm-current Output Fields Field Name Field Description Performance monitor. CURRENT Current (instantaneous) value of the performance monitor during the 15-minute interval. Minimum value measured. Copyright © 2018, Juniper Networks, Inc.
  • Page 495: Table 38: Tca Descriptions

    EDFA A-B Pump 0 Temperature(C), EDFA B-A Pump 0 EDFA’s pump 0 temperature for EDFA A-B or B-A. Temperature(C) EDFA A-B Pump 1 Temperature(C), EDFA B-A Pump 1 EDFA’s pump 1 temperature for EDFA A-B or B-A. Temperature(C) Copyright © 2018, Juniper Networks, Inc.
  • Page 496 EDFA B-A Pump 0 Current(0.1mA) 11600 EDFA B-A Pump 1 Current(0.1mA) 7900 EDFA B-A Pump 0 Temperature(C) 25.70 25.70 25.70 25.70 20.00 30.00 EDFA B-A Pump 1 Temperature(C) 25.70 25.70 25.70 25.70 20.00 30.00 Copyright © 2018, Juniper Networks, Inc.
  • Page 497: Table 39: Show Chassis Fpc Optical-Properties Amplifier-Chain Ila Pm-Currentday

    Output fields are listed in the approximate order in which they appear. Table 39: show chassis fpc optical-properties amplifier-chain ila pm-currentday Output Fields Field Name Field Description Performance monitor. Minimum value measured. Maximum value measured. Copyright © 2018, Juniper Networks, Inc.
  • Page 498: Table 40: Tca Descriptions

    EDFA A-B Pump 0 Temperature(C), EDFA B-A Pump 0 EDFA’s pump 0 temperature for EDFA A-B or B-A. Temperature(C) EDFA A-B Pump 1 Temperature(C), EDFA B-A Pump 1 EDFA’s pump 1 temperature for EDFA A-B or B-A. Temperature(C) Copyright © 2018, Juniper Networks, Inc.
  • Page 499 EDFA B-A Signal Output Power(0.01 dBm) -60 2100 EDFA B-A Pump 0 Current(0.1mA) 11600 EDFA B-A Pump 1 Current(0.1mA) 7900 EDFA B-A Pump 0 Temperature(C) 25.70 25.70 25.70 20.00 30.00 EDFA B-A Pump 1 Temperature(C) 25.70 25.70 25.70 20.00 30.00 Copyright © 2018, Juniper Networks, Inc.
  • Page 500: Table 41: Show Chassis Fpc Optical-Properties Amplifier-Chain Ila Pm-Interval

    Output fields are listed in the approximate order in which they appear. Table 41: show chassis fpc optical-properties amplifier-chain ila pm-interval Output Fields Field Name Field Description Performance monitor. Minimum value measured. Maximum value measured. Copyright © 2018, Juniper Networks, Inc.
  • Page 501: Table 42: Tca Descriptions

    EDFA A-B Pump 0 Temperature(C), EDFA B-A Pump 0 EDFA’s pump 0 temperature for EDFA A-B or B-A. Temperature(C) EDFA A-B Pump 1 Temperature(C), EDFA B-A Pump 1 EDFA’s pump 1 temperature for EDFA A-B or B-A. Temperature(C) Copyright © 2018, Juniper Networks, Inc.
  • Page 502 EDFA B-A Input Power(0.01 dBm) EDFA B-A Output Power(0.01 dBm) EDFA B-A Signal Output Power(0.01 dBm) 0 EDFA B-A Pump 0 Current(0.01mA) EDFA B-A Pump 1 Current(0.01mA) EDFA B-A Pump 0 Temperature(C) EDFA B-A Pump 1 Temperature(C) Copyright © 2018, Juniper Networks, Inc.
  • Page 503 Chapter 12: Operational Commands Copyright © 2018, Juniper Networks, Inc.
  • Page 504: Table 43: Show Chassis Fpc Optical-Properties Amplifier-Chain Ila Pm-Previousday

    Output fields are listed in the approximate order in which they appear. Table 43: show chassis fpc optical-properties amplifier-chain ila pm-previousday Output Fields Field Name Field Description Performance monitor. Minimum value measured. Maximum value measured. Copyright © 2018, Juniper Networks, Inc.
  • Page 505: Table 44: Tca Descriptions

    EDFA A-B Pump 0 Temperature(C), EDFA B-A Pump 0 EDFA’s pump 0 temperature for EDFA A-B or B-A. Temperature(C) EDFA A-B Pump 1 Temperature(C), EDFA B-A Pump EDFA’s pump 1 temperature for EDFA A-B or B-A. 1Temperature(C) Copyright © 2018, Juniper Networks, Inc.
  • Page 506 EDFA B-A Pump 0 Current(0.1mA) 1019 11600 EDFA B-A Pump 1 Current(0.1mA) 7900 EDFA B-A Pump 0 Temperature(C) 25.70 25.70 25.70 20.00 30.00 EDFA B-A Pump 1 Temperature(C) 25.70 25.70 25.70 20.00 30.00 regress@balvenie> Copyright © 2018, Juniper Networks, Inc.

Table of Contents