Table 87: Troubleshooting Temperature Alarms
Alarm
LCD
Type
Message
FPC
FPC-
number PIC
PIC-number
Hot
sib-number
Hot
cb-number
Yellow
Warm
(Continued)
CLI Message
Alarm Condition
FPC
FPC-number PIC
The FPC
temperature
PIC-number Temperature
exceeded the hot
Hot
temperature
threshold. If this
condition persists,
the FPC shuts down.
sib-number Temperature
The SIB temperature
exceeded the hot
Hot
temperature
threshold. If this
condition persists,
the SIB shuts down.
cb-number Temperature
The Control Board
temperature
Warm
exceeded the warm
temperature
threshold.
Solution
show chassis fpc
Issue the
command.
Verify that the room temperature
is within acceptable limits.
Verify that there is sufficient air
flow.
Verify that the cooling system in
the chassis is operating properly.
show chassis sib
Issue the
command.
Verify that the room temperature
is within acceptable limits.
Verify that there is sufficient air
flow.
Verify that the cooling system in
the chassis is operating properly.
Verify that the fans in the vertical
fan tray have not failed.
Verify that fans in the vertical fan
tray are running at appropriate
speed.
show chassis routing-
Issue the
engine
command.