Set Tone-Clock - Avaya Definity SI Maintenance Manual

Table of Contents

Advertisement

Maintenance Commands and Trouble-Clearing Aids
Field descriptions
Day of the Week:
Day of the Month:
Month:
Year:
Hour:
Minute:
Second:
Type
Daylight Savings
Rule

set tone-clock

This command sets the active tone/clock for a PN that has a duplicated tone/clock
circuit pack. Technicians should reset the default active tone clock in each PN
after using the set tone-clock command. If it is not in use, a single failure can
cause an unnecessary service outage. The schedule maintenance tone-clock
switch option does not reset the tone-clock to the default active if it was not active
at the beginning of the test.
Action/
Object
Qualifier
set
location
tone-clock
override
8-296
Issue 4 May 2002
Monday through Sunday.
1-31. The system also checks for leap year.
January through December.
1970-2999
0-23.
0-59
The system sets this field to zero when the time of day clock is
set.
Daylight-savings
Standard
= standard time
The daylight savings time rule number (0 to 15). Rule 0 is no
daylight savings time, and rule 1 defaults to U.S. daylight
savings time rule.
Qualifier Description
Physical location (PC) of the tone/clock to
be tested
Forces the set command into effect
regardless of the tone/clock circuit pack's
health.
Examples:
set tone-clock 01b
set tone-clock 1b
set tone-clock 01b override
set tone-clock a
= daylight savings time
Logins
Defaults
init
1 (one)
inads
craft
Feature
Interactions
none