Save The Setting State, Calibration Data And Memory Array (State Save) - Agilent Technologies 4294A Operating Manual

Precision impedance analyzer
Hide thumbs Also See for 4294A:
Table of Contents

Advertisement

Table 8-4
Agilent 4294A internal data and saving methods
Agilent
4294A internal data
Trace data
Data array (measurement data before
data trace storage)
Memory array (measurement data
before data trace storage)
Data trace array
Memory trace array
Graphics
Surface screen at the time of saving
1. Ö: always saving, on/off: saving on/off selection possible
2. The adapter setup data will not be lost even if you turn off the power or execute presetting with the
The adapter setup data is maintained for each adapter selection. For how to set up adapters (adapter selection and
adapter setup), refer to "Adapter Setting" on page 67.
NOTE
Before saving the calibration data (user calibration data array, fixture compensation data
array) with the STATE save, you must turn on (enable) each calibration function. For how
to turn on the user calibration functions, refer to "Turning User Calibration On/Off" on
page 148. For how to turn on the fixture compensation function, refer to "Turning the
fixture compensation on or off" on page 153.
Before saving the memory array or memory trace array with the STATE save or the DATA
save, you must save the data into the memory array and memory trace array with the
® MEMORY
into the memory array and memory trace array, refer to "Trace-based Comparison and
Calculation" on page 179.
For the each saving step, see "Save the setting state, calibration data and memory array
(State Save)" on page 271, "Save the calibration data and trace data (Data Save)" on page
273, and "Saving display screen (GRAPHICS save)" on page 288.

Save the setting state, calibration data and memory array (State Save)

The following steps are used to save the setting state, calibration data (user calibration data
and graphic compensation data), and memory array (memory data before being sent to the
memory trace through measurement parameter conversion) except for the Agilent 4294A
adapter setup data:
Step 1. Press the
Step 2. Press the
Step 3. Select the Agilent 4294A storage device.
Storage device
Floppy disk drive
Volatile memory disk
Chapter 8
Save and Recall the Agilent 4294A Internal Data
key. For more information on using the
key to display the save menu.
[Save]
key to display the storage device menu.
STORE DEV [ ]
Analysis and Processing of Result
Saving method and saved contents
State save
Data save
on/off
Ö
on/off
on/off
on/off
DATA ® MEMORY
Key operation
FLOPPY
MEMORY
1
Graphics save
Ö
key.
[Preset]
DATA
key to save data
271