Step 15. Select the dc bias mode.
dc bias mode
Voltage source (non-constant voltage mode)
Current source (non-constant current mode)
Voltage source (constant voltage mode)
Current source (constant current mode)
Step 16. Press the
currently selected is displayed in the key label
Softkey label
BIAS MODE [VOLT]
BIAS MODE [CURR]
BIAS MODE [C-VOLT]
BIAS MODE [C-CURR]
NOTE
The unit for the value in the cell located in the segment row and the dc bias level column
(BIAS) is modified according to the selected mode. Remember that you should verify
whether the mode is constant/non-constant voltage/current by using the key label of the
BIAS MODE [ ] key.
Step 17. When a voltage source (non-constant or constant voltage mode) is selected for the dc bias
mode, press the
voltage bias level value for the segment in the parameter settings located in the upper left
area of the screen.
Step 18. Use the keys or rotary knob of the ENTRY block in one of the following ways to specify a
value for the dc voltage bias level.
Enter the desired value with the numeric keys (
unit key (
Turn the rotary knob (
Press the step keys ([­][¯]) to set the desired value.
The setting above will add a new value for the dc voltage bias level to the cell located in
the segment row and the dc bias column (BIAS) of the list sweep table in editing mode.
Step 19. When a current source (non-constant or constant current mode) is selected for the dc bias
mode, press the
current bias level value for the segment in the parameter settings located in the upper left
area of the screen.
Step 20. Use the keys or rotary knob of the ENTRY block in one of the following ways to specify a
value for the dc current bias level.
Enter the desired value with the numeric keys (
Chapter 5
Sweeping Multiple Sweep Ranges with Different Conditions in a Single
key to return to the segment edit menu (2/3). Note that the dc bias mode
return
DC BIAS VOLTAGE
,
,
, or
[G/n]
[M/m]
[k/m]
[´1]
) until the desired value is set.
m m m m
DC BIAS CURRENT
Setting Measurement Conditions
Key stroke
VOLT
CURRENT
VOLT CONSTANT
CURRENT CONSTANT
of the
[ ]
BIAS MODE [ ]
Selected dc bias mode
Voltage source (non-constant voltage mode)
Current source (non-constant current mode)
Voltage source (constant voltage mode)
Current source (constant current mode)
key. This will display the current setting for the dc
to
,
, and
[0]
[9]
[.]
).
key. This will display the current setting for the dc
to
,
, and
[0]
[9]
[.]
Action (List Sweep)
key.
) and then press the
[-]
) and then press the
[-]