CHAPTER 6 IMAGE FORMATION SYSTEM
Caution:
1. If you have disconnected a connector
when
removing
developing assembly, be sure to clean
the inside of the ATR sensor
connector.
2. When mounting a developing
assembly to the copier, be sure to dry
wipe its bias electrode with lint-free
paper in advance to prevent
developing faults.
4. Removing the ATR Sensor of the
Y/M/C Developing Assembly
1) Remove
the
assembly.
2) Remove the screw [1], and slide the
developing blade cover [2] to the right to
remove. (In the case of the Y developing
assembly, slide it to the left.)
3) Remove the four screws [3], and
disconnect the connector [4]; then,
remove the developing blade unit.
Caution:
When assembling the parts, force down
the developing blade unit, and screw it in
place.
4) Remove the three screws [5], and detach
the ATR sensor [6].
Caution:
If you have replaced the ATR sensor, be
sure to replace the developer and select
the appropriate concentration in service
mode.
6-66
COPYRIGHT © 1999 CANON INC.
the
Y/M/C
Y/M/C
developing
CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
[1]
Figure 6-630
[4]
Figure 6-631
Force down.
Figure 6-632
[6]
[5]
Figure 6-633
[2]
[3]
Force down.