CHAPTER 13 TROUBLESHOOTING
B. Exposure System
Routing the Scanner Drive
1
Cable
Route the scanner drive cable as
indicated; i.e., [1] through [8]. Then, perform
"adjusting the mirror position."
2
Adjusting the Mirror Position
Be sure to adjust the position of the mirror
when you have routed the scanner drive cable.
1) Extend the arm of the mirror positioning
tool (FY9-3040-000) fully.
2) Fit the mirror positioning tool between
No. 1 mirror base and No. 2 mirror base.
3) Route the scanner drive cable to the No. 1
mirror mount.
13-14
COPYRIGHT © 1999 CANON INC.
2
8
6
8
Figure 13-214
CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
1
3
5, 8
4
Figure 13-215
Figure 13-216