CHAPTER 9 EXTERNALS / AUXILIARY MECHANISMS
4) Temporarily secure the drum motor
assembly [7] to the copier with seven
screws [8].
5) Mount the drum shaft positioning tool [9]
to the photosensitive drum frame unit with
the two screws [10] removed in step 2).
6) Secure the drum motor assembly in place
with seven screws.
7) Remove the drum shaft positioning tool,
slide out the photosensitive frame unit
from the copier; then, mount the unit and
parts removed in steps 1) and 2).
9-30
COPYRIGHT © 1999 CANON INC.
[8]
[10]
CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
[8]
[8]
[8]
[8]
Figure 9-733
[9]
Figure 9-734
[7]