CHAPTER 7 PICK-UP / FEEDING SYSTEM
C. Duplexing Unit

1. Removing the Duplexing

1) Remove the right center cover, right front
cover, face cover, and cassette switch
cover.
2) Open the waste toner box cover.
3) Slide out the duplexing unit.
4) Remove the two screws [1], and remove
the two stopper plates [2].
5) Remove the duplexing unit.

2. Removing the Feed Roller

1) Slide out the duplexing unit.
2) Detach the paper retaining guide plate [1]
by squeezing it slightly.
3) Remove the two resin E-rings [2], and
detach the feed roller [3] from the feed
roller shaft.
Caution:
The feed roller is identified by color
(front and rear):
Use the white feed roller for the front.
Use the black feed roller for the rear.
7-64
COPYRIGHT © 1999 CANON INC.
CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
[1]
[2]
Figure 7-741
[1]
Figure 7-742
[2]
Figure 7-743
[2]
[3]