CHAPTER 6 IMAGE FORMATION SYSTEM
Related Error Code
E021
This error code is indicated in response to any of the following errors (they are used to
monitor the developing assembly home position).
Detail code
0100
0200
0300
0400
0101
0201
0301
0401
6-30
COPYRIGHT © 1999 CANON INC.
The M developing assembly HP sensor does not turn on.
The C developing assembly HP sensor does not turn on.
The Y developing assembly HP sensor does not turn on.
The Bk developing assembly HP sensor does not turn on.
The M developing assembly HP sensor does not turn off.
The C developing assembly HP sensor does not turn off.
The Y developing assembly HP sensor does not turn off.
The Bk developing assembly HP sensor does not turn off.
CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)