5. Adjusting the Pressure of the
Separation Roller
1) Remove the two screws [2] and detection
lower guide [1].
2) Remove the paper guide [3].
3) Remove the two screws [4], and detach
the separation roller assembly [5].
COPYRIGHT © 1999 CANON INC.
CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 7 PICK-UP / FEEDING SYSTEM
[2]
Figure 7-711
[3]
Figure 7-712
[4]
[5]
Figure 7-713
[1]
[2]
[4]