WMUP (warm-up)
AINTR (initial
multiple rotation)
STBY (standby)
COPYRIGHT © 1999 CANON INC.
Period
From when the power switch is turned on to
when the surface temperature of the upper
fixing roller reaches 130°C.
From when the surface temperature of the upper
fixing roller reaches 130°C to when it reaches
158°C.
From when INTR ends to when the Copy Start
key is turned on or the power switch is turned
off.
Table 2-201
CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 2 BASIC OPERATION
Purpose
Waits until the fixing roller
warms up.
Measures and controls the
drum surface potential.
Waits for a press on the
Copy Start key or an
operation key.
2-5