Mounting The Fixing Upper Cleaning Belt - Canon CLC 1120 Service Manual

Color laser copier
Hide thumbs Also See for CLC 1120:
Table of Contents

Advertisement

CHAPTER 8 FIXING SYSTEM
2. Mounting the Fixing Upper
Cleaning Belt
The feed shaft, take-up shaft, and belt
(service part) are constructed as a single entity
(service part).
Mount the fixing upper cleaning belt by
reversing the steps used to remove it with the
following in mind:
1) Wind the cleaning belt around the cleaning
belt take-up shaft [1] two to three times.
2) Mount the feed shaft [2] of the cleaning
belt as shown.
3) Put the lever [3] of the fixing upper
cleaning belt length sensor inside.
4) Mount the take-up shaft of the cleaning
belt as shown.
5) Operate the cleaning belt feed lever [4]
10 to 20 times to remove all slack.
Caution:
The cleaning belt can become slack
when you release the upper roller unit
during servicing work. At the end of
each servicing job, be sure to operate the
cleaning belt drive assembly 10 to 20
times by hand to remove the slack.
8-22
COPYRIGHT © 1999 CANON INC.
[1]
Figure 8-424 (rear view)
(front)
CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
[2]
[3]
Figure 8-425
[4]
Figure 8-426
(rear)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Clc 1130Clc 1150

Table of Contents