CHAPTER 11 INSTALLATION
12) Press 'OK'.
13) Change the cassette size to suit the user's
needs while ATR is taking place (about 10
min).
See H. "Changing the Cassette Paper
Size."
14) Detach the hopper cap, by pulling it slowly
in horizontal direction.
Caution:
If you pull on the hopper cap at an angle,
the seal of the hopper cap will become
damaged, resulting chips falling into the
developing assembly. Take adequate
care.
15) Press 'ADJUST'.
16) Press 'DENS'.
17) Record the data shown on the DENS
screen on the service label.
·
The service label is attached behind the
Service data sheet cover inside the right
front cover. Be sure to mount the cover
after recording the data.
11-22
COPYRIGHT © 1999 CANON INC.
CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
Service label