CHAPTER 13 TROUBLESHOOTING
Address
bit
P00D
15
not used
14
not used
13
not used
12
not used
11
not used
10
not used
9
not used
8
not used
7
fixing oil pump driver error detection
6
not used
5
fixing upper thermistor open circuit detection
4
fixing lower thermistor open circuit detection
3
fixing upper heater error detection
2
fixing lower heater error detection
1
SSR1 (fixing upper heater side) error detection
0
SSR1 (fixing lower heater side) error detection
P00E
15
not used
14
not used
13
not used
12
not used
11
not used
10
not used
9
not used
8
not used
7
not used
6
toner suction fan (FM6) error detection
5
not used
7
not used
3
not used
2
not used
1
not used
0
delivery cooling fan (FM11) error detection
13-222
COPYRIGHT © 1999 CANON INC.
Description
CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
I/O>DC-CON
Remarks
1: HP
0: error if pump is in
operation.
1: error if pump is at rest.
1: open circuit
1: open circuit
1 error
1 error
1 error
1 error
1: error
1: error