Orientation of the Cleaning Belt
Mount the fixing cleaning belt as shown .
Orientation of the fixing Upper/
4
Lower Solenoid
Adjust the position so that the stroke [A]
is 5 ± 0.2 mm for the fixing paper solenoid and
4 ± 0.2 mm for the lower fixing solenoid.
COPYRIGHT © 1999 CANON INC.
CANON CLC1120/1130/1150 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 13 TROUBLESHOOTING
Figure 13-249 Fixing Upper Cleaning
Belt (rear view)
Figure 13-250 Fixing Lower Cleaning
Belt (rear view)