Basic Settings - Mitsubishi Electric MELSEC iQ-R Series User Manual

Master/local module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

Basic Settings

Set the items such as the own node of the CC-Link IE TSN Plus module.
Item
Own Node Settings
Refresh Settings
External Device Configuration
Own Node Settings
Set the items such as the IP address of the CC-Link IE TSN Plus module.
Item
Description
IP Address
IP Address
Set the IP address of the CC-Link IE TSN Plus module.
Set the class and subnet address of the CC-Link IE TSN Plus module to the same
settings as those of the EtherNet/IP devices that communicate with the CC-Link IE TSN
Plus module. Contact the network administrator before setting the IP address.
Subnet Mask
Set the subnet mask of the CC-Link IE TSN Plus module.
When setting the IP address of the default gateway and performing communication with
an EtherNet/IP device in another network through a router, set the subnet mask pattern
of the default gateway. All the devices in the same subnetwork should have a common
subnet mask. The subnet mask setting is not required for communication in a single
network.
Default Gateway
Set the default gateway of the CC-Link IE TSN Plus module.
Set the IP address of the relay device (default gateway) to access the EtherNet/IP
device in another network.
Set a value that satisfies the following conditions as the IP address of the default
gateway.
• The class of the IP address is A, B, or C.
• The subnet address of the gateway is the same as that of the CC-Link IE TSN Plus
• The host address part is not a sequence of "0" or "1".
Opening Method
Select how to open a connection when using UDP/IP communications or Passive open
of TCP/IP communications.
• When "Do Not Open by Program" is selected, a connection is open when the system
• When "Open by Program" is selected, the open/close processing is performed by a
■Precautions
The IP address to be set should have a different segment from the IP address to be set on the CC-Link IE TSN side. (
Page 75 Station No./IP Address Setting)
Description
Set the items such as the IP address of the CC-Link IE TSN Plus module.
Set the buffer memory of the CC-Link IE TSN Plus module to be refreshed.
Set the method and protocol used for communicating with external devices.
module.
receives the Active request. Program for open/close processing is not required.
program. The module cannot communicate when the CPU module is in STOP state.
Reference
Page 113 Own Node Settings
Page 114 Refresh Setting
Page 82 External Device
Configuration
Setting range
0.0.0.1 to 223.255.255.254
(Default: 192.168.4.1)
• Blank
• 128.0.0.0 to 255.255.255.252
(Default: Blank)
• Blank
• 0.0.0.1 to 223.255.255.254
(Default: empty)
• Do Not Open by Program
• Open by Program
(Default: Do Not Open by
Program)
8 PARAMETER SETTINGS
8.2 EtherNet/IP Parameter Settings
8
113