Receiving station: Local station (station No.1)
Classification
Setting details
Label to be defined
Define global labels as shown below:
• Program flow
 The master station checks that the send request bStartDirection (M0) is turned on, and transfers contents of uTransferFrom [0] to [3] to the send data W0 to
W3.
 When the transfer is completed, the master station turns on B0.
 The local station checks that B1000 is turned on, and transfers contents of the receive data W1000 to W1003 to uTransferTo [0] to [3] (D0 to D3).
 When the transfer is completed, the local station turns on B0.
 The master station checks that B1000 is turned on, and turns off B0.
 The local station checks that B1000 is turned off, and turns off B0.