UCMM message communications (client)

Without establishing a connection between the CC-Link IE TSN Plus module and the external device (server), message
communications are performed at any timing.
Once per request, communications are performed with the external device without opening a connection.
The set command request is sent to the external device set in the request area of the 'Class3/UCMM communication area'
(Un\G7751680 to Un\G8275967) in the CC-Link IE TSN Plus module. The command response from the external device is
stored in the response area of 'Class3/UCMM communication area' (Un\G7751680 to Un\G8275967).
CPU module
(1)
(1) Set request data by a program
(2) Turn on 'Class3/UCMM communication execution request' (Un\G7749632 to Un\G7749647).
(3) 'Class3/UCMM communication execution request acceptance' (Un\G7749648 to Un\G7749663) turns on.
(4) Command processing execution
(5) Store the response data in the buffer memory.
(6) 'Class3/UCMM communication execution completion' (Un\G7749664 to Un\G7749679) turns on.
RJ71GN11-EIP
Request area in 'Class3/UCMM
communication request/response
area' (Un\G7751680 to Un\G8275967)
Response area in 'Class3/UCMM
communication request/response
area' (Un\G7751680 to Un\G8275967)
Client
(2)
(3)
Command request
Command response
(5)
(6)
12.3 Message Communication Function (Client)
External device
Server
(4)