Structure of unicast mode

This mode indicates the availability of connection with a network configuration device when "Communication Mode" under
"Application Settings" is set to "Unicast".
When the communication speed for the master station is set to 1Gbps
This mode indicates the availability of connection with a network configuration device when "Communication Speed" of the
master station is set to "1Gbps".
: Connection available, : Connection available via a switching hub, : Connection not available
S: TSN hub available
H: General-purpose hub available
Device on the master
Device on the end side (The side far from the master station)
station side
Local station
(The side near the
(CC-Link IE TSN
master station)
Class B device)
1Gbps
*4*5
Master
1Gbps
S
station
(CC-Link IE
TSN Class B
device)
*5*7
S
Local station
1Gbps
(CC-Link IE
100Mbps
TSN Class B
device)
*5
S
Remote
1Gbps
station
100Mbps
(CC-Link IE
TSN Class B
device)
Local station
1Gbps
(CC-Link IE
100Mbps
TSN Class A
device)
Remote
1Gbps
station
100Mbps
(CC-Link IE
TSN Class A)
device
*1 For a slave station with a communication speed of 100Mbps, set "Communication Period Setting" to "Low-Speed" (16 times).
*2 A connection cannot be made if the total cyclic data size of all slave stations on the CC-Link IE TSN Class A device side that form a
boundary between CC-Link IE TSN Class B and CC-Link IE TSN Class A devices exceeds 2K bytes. ( Page 56 Calculation of the
total cyclic data size)
*3 A connection cannot be established if the total cyclic data size of all slave stations on the 100Mbps device side exceeds 2K bytes for
devices that form a boundary between the communication speed of 1Gbps and 100Mbps. ( Page 56 Calculation of the total cyclic
data size)
*4 If the device on the master station side is a CC-Link IE TSN Plus module, only P1 can be connected.
*5 If the device on the end side is a CC-Link IE TSN Plus module, only P1 can be connected.
*6 If the device on the master station side is a CC-Link IE TSN Plus module, P2 can be connected without passing through a switching hub.
*7 Connection is not possible if the device on the master station side is a CC-Link IE TSN Plus module.
*8 If the device on the master station side is a CC-Link IE TSN Plus module, only P2 can be connected.
Precautions
When a TSN hub is used, check the TSN hub specifications on the CC-Link Partner Association website (www.cc-link.org).
Appendix 11 Structure of CC-Link IE TSN Class B/A Devices (Protocol Version 1.0 Only) and Ethernet Devices
Remote station
(CC-Link IE TSN
Class B device)
100Mbps
1Gbps
100Mbps
*4
*1*4
S
S
*7
*1*3*7
S
S
*1*3
S
S
*1*3
S
Local station
Remote station
(CC-Link IE TSN
(CC-Link IE TSN
Class A device)
Class A device)
1Gbps
100Mbps
1Gbps
*4
*4
SH
SH
*2*7
*2*7
SH
SH
*2
*2
SH
SH
*2
*2
SH
SH
*2
*2
SH
SH
Ethernet device
100Mbps
1Gbps
100Mbps
*1*4
*6
S
SH
SH
*1*2*7
*8
*6*8
SH
SH
SH
*1*2
SH
SH
SH
*1*2*3
SH
SH
*1*2
SH
SH
SH
*1*2
SH
SH
SH
*1*2
SH
SH
APPX