11.3
Examples of Communication with CC-Link IE TSN
Class A Remote Stations
When "Communication Mode" is set to "Multicast", the local station cannot obtain data output by the CC-Link IE TSN Class A
remote station. Use the following communication examples so that the local station can obtain data output by the CC-Link IE
TSN Class A remote station.

System configuration

The following is an example of communications between the CC-Link IE TSN Class B master station (station No.0), CC-Link
IE TSN Class A remote station (station No.1), and local station (station No.2).
System configuration
• Power supply module: R61P
• CPU module: R04CPU
• Master station (No.0): RJ71GN11-EIP
• Local station (No.2): RJ71GN11-T2
• Remote station (No.1): CC-Link IE TSN Class A remote
No.0 Class B
No.0: CC-Link IE TSN Class B master station (station No.0)
No.1: CC-Link IE TSN Class A remote station (station No.1)
No.2: CC-Link IE TSN Class B local station (station No.2)
Link device assignment
For RX and RWr, 256 points are assigned to each station.
For RY and RWw, 256 points are assigned to a remote station and 512 points are assigned to a local station.
■RX/RY assignment
Each of the following No.0 to No.2 represents a station number.
• No.0: Master station (station No.0)
• No.1: Remote station (station No.1)
• No.2: Local station (station No.2)
11 PROGRAMMING
232

11.3 Examples of Communication with CC-Link IE TSN Class A Remote Stations

No.1 Class A
No.2 Class B