From "Module List", add "RJ71GN11-EIP(T+E)" to the list of EtherNet/IP devices and then configure the settings as
follows.
If "RJ71GN11-EIP(T+E)" is not shown in the "Module List", it is necessary to add the EDS file.
For adding the EDS file, refer to the following.
Page 129 Adding the EDS file
9.
Double-click "<Detailed Setting>" in the "Connection Setting" column and set the connection of the server.
10.
Select the server under "Scanner" in "Connection List" and click the [Add Connection] button.
11.
Select "Connection (Class3 Message Communications)" in "Select Connection to be Added:" and click the [OK] button.
12.
Set the parameter for the Class3 message communications in "Connection Detailed Setting".
13.
Click the [Apply] button.
14.
Click the [OK] button to close the connection settings.
15.
Select [Close with Reflecting the Setting] and close the "EtherNet/IP Configuration" window.
13 PROGRAMMING
330
13.5 Class3 Message Communications Communication Example