TERMS

Unless otherwise specified, this manual uses the following terms.
Term
Adapter
Buffer memory
*1
CC-Link IE TSN Class
CC-Link IE TSN Protocol
version 1.0
CC-Link IE TSN Protocol
version 2.0
Conformance test
Control CPU
CPU module (built-in Ethernet
port part)
Cyclic data transfer processing
Dedicated instruction
Device
Engineering tool
EtherNet/IP device
Explicit message
General-purpose hub
Global label
Grandmaster
Group No.
Intelligent function module
Link device
Link refresh
Local station
Master station
Module label
Multicast filter
Multicast mode
Originator
Relay station
Remote station
Description
For EtherNet/IP communications, an EtherNet/IP device that has only the function by which a connection is opened (target
function)
Memory in an intelligent function module to store data such as setting values and monitor values.
For CPU modules, it refers to memory to store data such as setting values and monitor values of the Ethernet function, or
data used for data communication of the multiple CPU system function.
A group of devices and switching hubs compatible with CC-Link IE TSN, classified according to the functions and
performance by the CC-Link Partner Association.
For CC-Link IE TSN Class, refer to the CC-Link IE TSN Installation Manual (BAP-C3007ENG-001) published by the CC-Link
Partner Association.
This protocol is used to perform communications by using the time sharing method defined by IEEE 802.1AS or IEEE 1588
for time synchronization.
This protocol is used to perform communications by using the time sharing method defined by IEEE 802.1AS and time-
managed polling method for time synchronization.
Test performed for communications of a CC-Link or CC-Link IE product to ensure their high reliability.
For details, refer to the CC-Link Partner Association website (www.cc-link.org).
A CPU module that controls connected I/O modules and intelligent function modules. In a multiple CPU system, a control
CPU can be set for each module.
A built-in Ethernet port part of a CPU module (CPU part for an RnENCPU)
Processing of a cyclic transmission from its start to finish, performed by all the stations on a single network. The processing
is performed asynchronously with the sequence scan of the CPU module.
The cyclic data transfer processing time varies depending on data volume and the number of transient transmission
requests.
An instruction that simplifies programming for using functions of intelligent function modules
A memory of a CPU module to store data. Devices such as X, Y, M, D, and others are provided depending on the intended
use.
A tool used for setting up programmable controllers, programming, debugging, and maintenance
A device, personal computer, and other equipment connected via EtherNet/IP for data communications
For EtherNet/IP, communication executed at a non-fixed interval and transient transmission
A CC-Link IE TSN Class A switching hub authorized by CC-Link Partner Association ( Page 72 Switching hub (when the
system configured with CC-Link IE TSN))
A label that is valid for all the program data when multiple program data are created in the project. There are two types of
global label: a module specific label (module label), which is generated automatically by GX Works3, and an optional label,
which can be created for any specified device.
A source device or station to synchronize clocks in the time synchronization via PTP (Precision Time Protocol)
Number that is assigned for transient transmission to any given stations. By specifying a group of stations as transient
transmission target, data can be sent to the stations of the same group No.
A module that has functions other than an input or output, such as an A/D converter module and D/A converter module
A device (RX, RY, RWr, RWw, LB, or LW) in a module on CC-Link IE TSN
Processing of data transfer between link devices of the network module and CPU module devices. Link refresh is performed
in "END processing" of the sequence scan of the CPU module.
A station that performs cyclic transmission and transient transmission with the master station and other local stations
A station that controls the entire network. This station can perform cyclic transmission and transient transmission with all
stations. Only one master station can be used in a network.
A label that represents one of memory areas (I/O signals and buffer memory areas) specific to each module in a given
character string. For the module used, GX Works3 automatically generates this label, which can be used as a global label.
A filter function that selects whether to send cyclic data of multicast mode received by the own station to the subsequent
stations.
Setting parameters for this function are not required because the master station automatically sets the parameters according
to the system configuration.
A communication mode used to send cyclic data to multiple stations
For EtherNet/IP communications, an EtherNet/IP device on the connection opening side
A station that relays data link to other station with mounting more than one network modules on one programmable
controller.
A station that exchanges I/O signals (bit data) and I/O data (word data) with another station by cyclic transmission. This
station can perform transient transmission.