Class1 communication status
■Class1 communication status (Un\G7734272 to Un\G7734319)
This area stores the communication status of Class1 communications for each connection number.
Address
Un\G7734272 to Un\G7734287
Un\G7734288 to Un\G7734303
Un\G7734304 to Un\G7734319
*1 For a Producer Tag during tag communications, it turns on only when communications with all the connected Consumer Tags are
stopped.
During tag communications, if one Producer Tag is connected to multiple Consumer Tags through multicast
communications, 'Class1 data link status' (Un\G7734272 to Un\G7734287) turns on if even one
communication operation is normal.
Note that if the connections with all Consumer Tags are not communicating or have a communication error,
'Class1 data link status' (Un\G7734272 to Un\G7734287) turns off.
The following table lists the assignments for each area.
The value of each bit indicates the connection number.
Address
Class1 data
Class1
Class1
link status
error status
reserved
station
Un\G7734272
Un\G7734288
Un\G7734304
Un\G7734273
Un\G7734289
Un\G7734305
Un\G7734274
Un\G7734290
Un\G7734306
Un\G7734275
Un\G7734291
Un\G7734307
Un\G7734276
Un\G7734292
Un\G7734308
Un\G7734277
Un\G7734293
Un\G7734309
Un\G7734278
Un\G7734294
Un\G7734310
Un\G7734279
Un\G7734295
Un\G7734311
Un\G7734280
Un\G7734296
Un\G7734312
Un\G7734281
Un\G7734297
Un\G7734313
Un\G7734282
Un\G7734298
Un\G7734314
Un\G7734283
Un\G7734299
Un\G7734315
Un\G7734284
Un\G7734300
Un\G7734316
Un\G7734285
Un\G7734301
Un\G7734317
Un\G7734286
Un\G7734302
Un\G7734318
Un\G7734287
Un\G7734303
Un\G7734319
Item
Description
Class1 data link status
Stores the data link status of connection numbers 1 to 256.
It automatically turns on when communication recovers from an error.
• On: Establishing connection
• Off: Error caused by no connection settings, establishing connection,
Class1 error status
Stores the error status of connection numbers 1 to 256.
It automatically turns off when communication recovers from an error.
• On: Connection timeout, error caused by setting mismatch, connection error,
• Off: No connection settings, establishing connection
Class1 reserved station
Stores the setting status of the reserved station of connection numbers 1 to 256.
• On: Reserved station
• Off: Not set as reserved station
Bit
b15 b14 b13
b12 b11
16
15
14
13
32
31
30
29
48
47
46
45
64
63
62
61
80
79
78
77
96
95
94
93
112
111
110
109
128
127
126
125
144
143
142
141
160
159
158
157
176
175
174
173
192
191
190
189
208
207
206
205
224
223
222
221
240
239
238
237
256
255
254
253
connection timeout, and setting mismatch
*1
and external device error
b10 b9
b8
b7
b6
12
11
10
9
8
7
28
27
26
25
24
23
44
43
42
41
40
39
60
59
58
57
56
55
76
75
74
73
72
71
92
91
90
89
88
87
108
107
106
105
104
103
124
123
122
121
120
119
140
139
138
137
136
135
156
155
154
153
152
151
172
171
170
169
168
167
188
187
186
185
184
183
204
203
202
201
200
199
220
219
218
217
216
215
236
235
234
233
232
231
252
251
250
249
248
247
b5
b4
b3
b2
b1
b0
6
5
4
3
2
1
22
21
20
19
18
17
38
37
36
35
34
33
54
53
52
51
50
49
70
69
68
67
66
65
86
85
84
83
82
81
102
101
100
99
98
97
118
117
116
115
114
113
134
133
132
131
130
129
150
149
148
147
146
145
166
165
164
163
162
161
182
181
180
179
178
177
198
197
196
195
194
193
214
213
212
211
210
209
230
229
228
227
226
225
246
245
244
243
242
241
APPX
Appendix 3 Buffer Memory
A
493

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r cc-link ie tsn plus

Table of Contents