Simple
Detailed
display
display
Number of
RWw Setting
input/output
RWr Setting
*4
word points
LB Setting
LW Setting
Parameter Automatic Setting
PDO Mapping Setting
IP Address
Subnet Mask
Default Gateway
Reserved/Error Invalid Station
Network Synchronous
Communication
Communication Period Setting
Station Information
Description
Assign RWw/RWr points in increments of 4. ( Page 143 Communications
using RX, RY, RWr, and RWw)
Modules with settings provided by the profile are automatically set from selected
models. (Excluding modules with a number of points that is not fixed)
Assign LB points in increments of 16 and LW points in increments of 1. ( Page
148 Communications using LB and LW)
Modules with settings provided by the profile are automatically set from selected
models. (Excluding modules with a number of points that is not fixed)
Set whether to set the parameters of each slave station automatically.
This cannot be set for extension modules. However, the parameter automatic
setting of extension modules is interlocked with the settings of the connected main
module.
Set the PDO mapping to the station that supports CANopen communications.
( Page 107 PDO mapping setting)
Set the IP address of a station that performs cyclic transmission.
Set a subnet mask to identify a network address.
Set the same value for the master station and slave station. Even if a slave station
has a different subnet mask from the master station, it does not result in an input
error.
If 255.255.255.255 is set, leave it empty.
Set the default gateway address to connect to the external network.
If 223.255.255.255 is set, leave it empty.
Set the slave station as a reserved station or error invalid station.
• No Setting: The slave station is connected to the network.
• Reserved Station: The slave station is reserved for future expansion. By using a
reserved station, link device assignment will not change even if the slave station
is added (reservation is canceled). Therefore, modification of the program is not
required. Physical connection of the slave station on the network is not required.
• Error Invalid Station: Even if a slave station is disconnected during data link, the
master station will not detect the slave station as a faulty station.
Set whether to synchronize each slave station with network synchronous
communication.
When multiple communication cycles are set, set the cycle of each slave station.
( Page 166 Communication cycles coexistence)
■Alias
Enter the name of a device if required.
The name entered is displayed in "Network Status" of the "CC-Link IE TSN/CC-
Link IE Field Diagnostics" window.
For the extension module of the remote station, the name is not displayed in the
"CC-Link IE TSN/CC-Link IE Field Diagnostics" window, even if entered.
■Comment
Information entered in "Comment1" on the "Properties" window displayed by right-
clicking the module in the list of stations or the network map is displayed.
■Station-specific mode setting
Set the station-specific mode of the slave station. (Only when the slave station
supports the station-specific mode)
Setting range
• Number of points: 4 to 8192
• Start: 0H to 1FFCH
• End: 3H to 1FFFH
(Default: Varies depending on the
set module)
• Number of points: 16 to 32768
• Start: 0H to 7FF0H
• End: FH to 7FFFH
(Default: Varies depending on the
set module)
• Number of points: 1 to 16384
• Start: 0H to 3FFFH
• End: 0H to 3FFFH
(Default: Varies depending on the
set module)
• Checked: Distribute parameters
• Not checked: Do not distribute
parameters
(Default: Not checked)
0.0.0.1 to 223.255.255.254
(00.00.00.01 to DF.FF.FF.FE)
(Default: The first to third octets have
the same values as the master
station, the fourth octet has a serial
number from 1 to 254)
• 0.0.0.1 to 255.255.255.255
(00.00.00.01 to FF.FF.FF.FF)
• Empty (0.0.0.0)
*2
(Default: empty
• 0.0.0.1 to 223.255.255.254
(00.00.00.01 to DF.FF.FF.FE)
• Empty (0.0.0.0)
(Default: empty)
• No Setting
• Reserved Station
• Error Invalid Station
(Default: No setting, master station is
fixed as empty)
• Synchronous
• Asynchronous
(Default: Asynchronous)
• Basic Period
• Normal-Speed
• Low-Speed
(Default: Basic Period)
Up to 32 one-byte characters (one-
byte or two-byte)
(Default: empty)
Up to 32 one-byte characters (one-
byte or two-byte)
(Default: empty)
The setting varies depending on the
set module.
8 PARAMETER SETTINGS
8.1 Parameter Settings for CC-Link IE TSN
8
)