Appendix 5 List of Link Special Register (SW)
Description
Stores the minor error occurrence status of each station.
When the target station is RJ71GN11-EIP, the occurrence status on the CPU module
is stored.
0: Normal, or a moderate or serious error occurring
1: Minor error occurring
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW0110
16 15 14 13 12 11 10
SW0111
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW0112
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW0113
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW0114
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW0115
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW0116
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
SW0117
Each number in the table represents a station number.
 is fixed to 0.
(Conditions)
• Reserved stations and stations that surpass the maximum station number are
ignored.
• Since a local station cannot obtain the station information of the CC-Link IE TSN
Class A remote station when communicating in multicast mode, "0: Normal, or a
moderate or serious error occurring" is reflected to the CC-Link IE TSN Class A
remote station.
When the slave station parameter automatic setting is completed with an error, the bit
of the target station is turned on.
Off:
Completed successfully
On: Completed with an error
When completed with an error, the error code is stored in the 'Detailed execution
result of slave station parameter automatic setting' (SW0194).
When completed with an error caused by the master station, the bit is not turned on.
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW0160
16 15 14 13 12 11 10
SW0161
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW0162
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW0163
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW0164
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW0165
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW0166
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
SW0167
Each number in the table represents a station number.
 is fixed to 0.
When the slave station parameter automatic setting is completed with an error, the
error code is stored.
When completed with an error caused by the slave station, the bit of the target station
of 'Execution result of slave station parameter automatic setting function' (SW0160 to
SW0167) is turned on.
Stores the processing results of the link dedicated instruction that used channel 3 of
the own station.
0: Completed successfully
1 or greater: Completed with an error (Error code is stored.)
Stores the processing results of the link dedicated instruction that used channel 4 of
the own station.
0: Completed successfully
1 or greater: Completed with an error (Error code is stored.)
Stores the processing results of the link dedicated instruction that used channel 5 of
the own station.
0: Completed successfully
1 or greater: Completed with an error (Error code is stored.)
9
8
7
6
5
4
3
2
120 119 118 117 116 115 114 113
9
8
7
6
5
4
3
2
120 119 118 117 116 115 114 113
Availability
Master
Local station
station
Unicast
mode
1
1
Multicast
mode
*1