Mitsubishi Electric MELSEC iQ-R Series User Manual page 518

Master/local module
Hide thumbs Also See for MELSEC iQ-R Series:
Table of Contents

Advertisement

No.
Name
SW00C8
Parameter
to
setting status
SW00CF
SW00D0
Error invalid
to
station setting
SW00D7
status
SW00E8
Station type
to
match status
SW00EF
APPX
516
Appendix 5 List of Link Special Register (SW)
Description
Stores the status of parameter settings.
0: Station not set in the parameter
1: Station set in the parameter
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW00C0
16 15 14 13 12 11 10
SW00C1
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW00C2
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW00C3
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW00C4
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW00C5
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW00C6
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
SW00C7
Each number in the table represents a station number.
 is fixed to 0.
(Conditions)
• Stations that surpass the maximum station number are ignored.
Stores the error invalid station setting status of each station.
0: Station other than an error invalid station
1: Error invalid station
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW00D0
16 15 14 13 12 11 10
SW00D1
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW00D2
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW00D3
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW00D4
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW00D5
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW00D6
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
SW00D7
Each number in the table represents a station number.
 is fixed to 0.
(Conditions)
• Stations that surpass the maximum station number are ignored.
Stores the match status between the station type set in the master station and that of
the slave station.
0: Station type match
1: Station type mismatch
b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1 b0
SW00E8
16 15 14 13 12 11 10
SW00E9
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
SW00EA
48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33
SW00EB
64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49
SW00EC
80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65
SW00ED
96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81
SW00EE
112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97
SW00EF
Each number in the table represents a station number.
 is fixed to 0.
9
8
7
6
5
4
3
2
120 119 118 117 116 115 114 113
9
8
7
6
5
4
3
2
120 119 118 117 116 115 114 113
9
8
7
6
5
4
3
2
120 119 118 117 116 115 114 113
Availability
Master
Local station
station
Unicast
mode
1
1
1
Multicast
mode
*1
*1
*1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-r cc-link ie tsn plus

Table of Contents